Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 147 of 147 items found.

  • Class 2 Sound Level Meter

    SP79 - Martindale Electric Co. Ltd

    The SP79 is a Class 2 sound level meter for on-site measurements in accordance with Noise at Work legislation in industrial and office environments. Featuring A and C frequency weighting and fast and slow time weighting, the compact design can be handheld, or mounted on a tripod for longer term monitoring of Min / Max values. Detailed recording and analysis can be made using the AC and DC outputs. The SP79 complies with BS EN 61672-1:2003 and is supplied with a detachable windshield and hard carry case. The large high contrast display includes both digital reading and analogue bar graph. An optional Class 2 sound level calibrator is available to verify accuracy before and after readings in accordance with international standards. The SPC70 is simple to use and provides a 1kHz reference at 94dB and 114dB.

  • 400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device

    783927-01 - NI

    400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device - The USRP-2952 provides an integrated hardware and software solution for rapidly prototyping high-performance wireless communication systems. Built on the LabVIEW reconfigurable I/O (RIO) architecture, USRP RIO delivers an integrated hardware and software solution, so researchers can prototype faster and shorten time to results. You can prototype a range of advanced research applications that include multiple input, multiple output (MIMO); synchronization of heterogeneous networks; LTE relaying; RF compressive sampling; spectrum sensing; cognitive radio; beamforming; and direction finding. The USRP-2952 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) reference clock. GPS disciplining delivers improved frequency accuracy and synchronization capabilities.

  • 400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device

    783151-01 - NI

    400 MHz to 4.4 GHz, GPS-Disciplined OCXO, Reconfigurable USRP Software Defined Radio Device - The USRP-2952 provides an integrated hardware and software solution for rapidly prototyping high-performance wireless communication systems. Built on the LabVIEW reconfigurable I/O (RIO) architecture, USRP RIO delivers an integrated hardware and software solution, so researchers can prototype faster and shorten time to results. You can prototype a range of advanced research applications that include multiple input, multiple output (MIMO); synchronization of heterogeneous networks; LTE relaying; RF compressive sampling; spectrum sensing; cognitive radio; beamforming; and direction finding. The USRP-2952 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) reference clock. GPS disciplining delivers improved frequency accuracy and synchronization capabilities.

  • Handheld Water Quality Meters

    LAQUA PC210 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • HBM Verification Tester

    HBM-VT - High Power Pulse Instruments GmbH

    - HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm

  • Handheld Water Quality Meters

    LAQUA PC220 - HORIBA, Ltd.

    - Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty

  • SWR True Antenna Analyzer

    COMM-connect

    SWR True Antenna Analyzer is a versatile analyzer covering all major communication bands from 30MHz to 2700MHz. The SWR True will analyze antennas and cables. Measurements are represented graphically as VSWR or Return Loss plots. The built in PLL synthesized generator offers a superior accuracy with small step size. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The SWR True instrument is small, handy and light weight battery operated with more than 6 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.

  • Audio Test Software

    Soft Hearts LLC

    1. Distortion free stimulus even the equalized stimulus.2. Unlimited channels acquisition and processing. (Hardware limited)3. Human correlated listening test(Bark Scale intensity chart). (Requires large memory)4. Hi Res intensity chart for buzz/pop detection. (Requires large memory)5. Auto equalization method with target dBSPL accuracy.6. TCP client for test framework integration.7. Easy limits and logs development.8. Easy logs visualization module.9. Auto waveform alignment and triggering.(Upto single point alignment accuracy)10. Easy regression testing via TCP client.11. Standard Magnitude, Phase, THD, THD+N, Rubb&Buzz, Pink Noise, Noise Tests.12. Unlimited calibrations and equalization for scaling to different products and stations.13. Lowest test system and test sequence development times.14. Requires minimal training and debugging.15. Automatically avoid Reference speaker play and stop pops.16. WMD/ASIO driver compatible sound cards supported.(B&K 3670 recommended)

  • ​Paramagnetic Oxygen Analyzer

    Model T802 - Teledyne Monitor Labs

    The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T802 comes with the NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • AC Fuel Flow Signal Generator

    TA-100 - Tech-Aid Products

    The TA-100 signal generator was designed to facilitate testing of aircraft fuel flow indicators that require two input signals designated as “Drum” and “Impeller”. This generator provides both signals so as to provide a direct interface to the fuel flow indicator under test. The generator also provides switched power out to the unit under test as well as a 5v source for testing the bezel lighting. The original design was built around the requirements for the AMETEK series indicators (pn: 10171 series). This generator simulates a reference and a time delayed signal of appropriate amplitude for an indication of up to 1200pph for the indicator under test. The “PPH Select” switch provides fixed signal delays representing 0, 200, 400, 800, 1000 and 1200pph flow rates respectively, this provides the mechanic with an expedient check of the indicators accuracy. The “PPH Adjust” control allows the mechanic to vary the signal delay throughout the full range and serves as a good method for checking of pointer smoothness from stop to stop. The unit’s front panel also provides test jacks to monitor the “FDR Output” as well as the drum and impeller signals. The TA-100 requires only 28Vdc to operate. This generator provides a very economical approach to any repair facility or flight department as it becomes an alternative to purchasing two bench top signal generators. The TA-100 generator at the very least can provide a simple functional test and eliminate the high cost of exchanging an indicator as a function of troubleshooting the aircraft system.

  • Circuit Breaker Test Equipment

    IBEKO Power AB

    DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.

  • Emissions Test System

    PC-114 - Com-Power Corporation

    Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.

Get Help