Showing results: 2551 - 2565 of 2660 items found.
-
Model BCA6/12M -
Aplab Limited
- Instant Measurement of energy stored in a storage battery- Tests 6V or 12V Lead Acid Batteries from 2Ah to 100Ah Capacity- Suitable for any SLA, GEL or Car Flooded Batteries- Displays DC Voltage and Balance available Ah capacity of the battery- Shows the Internal Resistance of the battery- Powered by the Battery under test- Micro-processor based digital control of entire testing process- Specially designed 4-terminal probing Battery Clamp of 100A capacity- Test simulates 20-Hr discharge test (C/20) with a few seconds- Bright, back-lit LED Display for test process display- On-screen User Guidance for testing on the built-in LCD Screen- Easy to use, portable and robust housing in a custom extrusion
-
785186-01 -
NI
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
783863-01 -
NI
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Extech EX365 -
Extech Instruments Corporation
The EX365 is a Compact Industrial True RMS MultiMeter with a Built in Non Contact Voltage Detector. Featuring highly accurate True RMS measurements, LoZ for the prevention of false readings caused by ghost voltages, .5% basic accuracy, a 1000V AC/DC volt range, resistance up to 40MΩ, continuity beeper with visual alert, smart data hold, peak hold, auto power off with disable, relative mode for capacitance zero and offset adjustment. Additionally, the EX365 excels in frequency and capacitance measurements as well as commercial applications which require AC/DC current measurements from 1 mA to 10A. Complete with test leads, 9V battery, holster with tilt stand and built-in magnet.
-
DRK8026 -
Shandong Drick Instruments Co., Ltd.
Determine crystal melting point of the substance to make sure its purity. Mainly used for determining the meltingpoints of medicine,dyestuff,spice and other organic crystal compounds.Using photoelectric automatic detection, Dot matrix LCD display picture technology, digital keyboard input, and has the initial melting, final weld automatic display,automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperature system uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.
-
6212A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.
-
6212A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.
-
783864-02 -
NI
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
785189-01 -
NI
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
783864-01 -
NI
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
783863-02 -
NI
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
779592-01 -
NI
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
ZDG-25 -
Shanghai Dean Electrical Co., Ltd
Executive standard: GB/T4074.3-2008/IEC60851-3Inspection standard: JB/T4279.9-2008Meet GB/T6109-2008 standard requirementsUsed to test the film scrap resistance of enamelled round wires with nominal conductor diameter above0.250mm;Application of SCM control,enter the weight value, operation will be completed automatically: put down the scraping rod, stop while film scratch, calculate and show the scraping force, raise the scraping rod, return to zero, sample rotates 120°and repeat the same operation, calculate and show the scraping force of three times and average scraping force.When film is scratched, film scraper would automatically stop scraping, with exposed conductor of sample<3mmWith the advantages of high sensitivity, good repeatability, stable and reliable characteristics.
-
WGQ-60 -
Shanghai Dean Electrical Co., Ltd
Executive standard: NEMA、JIS; Inspection standard: JB/T4279.15-2008Used to detect the scraping resistance of coating and cable insulation layer of flat wires of 0.800~5.600mm (narrow side) and the silk and enamel covered round wires with nominal conductor diameter of 0.100~5.000mm;Application of SCM control allows for fast operation and strong anti-interference capacity;Sample support table allows for parallel rise and fall, maintaining close contact between the entire plane with sample;Scratching needle is vertical to the paint scraping direction and parallel with sample supporting table;When film is scratched and the action current is ≥5mA, painting scraper would automatically stop scraping;LED would automatically display the number of scraping.
-
Ono Sokki
•Adopted FAMS-R5 system for motorcycle chassis dynamometer•Gas emission test, durability test, performance test, and environmental test are applicable to various vehicles (motorcycle, tricycle,ATV).•Newly designed measurement unit in a test room makes measurement easier.•Reduction of initial cost, space saving, and less maintenance items by lineup of electric inertia type chassis dynamometer that can be used for small to large vehicles.•Components necessary for emission test are included, such as front wheel holding unit, engine cooling fan, drivers display.•Application software necessary for emission test is installed, such as road resistance setting software, drivers aid,gas emission data processing software, rear axle output data processing software.