Filter Results By:

Products

Applications

Manufacturers

Showing results: 481 - 495 of 536 items found.

  • ESS Performance Test System

    Bloomy Controls, Inc.

    The Energy Storage System (ESS) Performance Test System is used to evaluate, test, and certify the performance of energy storage systems up to 2MW. The system is a configurable platform with over 200 channels of simultaneously measured AC and DC voltages and currents, environmental temperatures, airflow, and communications. Intuitive software provides real-time monitoring and analysis of power, energy and efficiency to adhere with industry standards. The test system interfaces hardware such as load banks, and controls the ESS to simulate utility applications such as peak shaving and frequency regulation.

  • Solar Analyzers

    Meco Instruments Pvt. Ltd.,

    Max. solar system power (Pmax) search by Auto-scan: 1000V, 12A (12000W capability)The analyzer and the Remote Solar Detector is connected by Bluetooth wireless communication (Bluetooth 2.1 + EDR Class 1)The Remote Solar Detector is moisture-proofIntelligent test logic with no personnel attendance required in the field Solar system analyzer waits and tests the system until appropriate sunlight irradiance is detectedMax. voltage (Vpm) at Pmax, Max. current (Ipm) at Pmax Voltage at open circuit (Voc), Current at short circuit (Isc)Efficiency (%) calculation of solar systemTemperature measurement of solar panelsIrradiance measurement of sun lightSeries resistance (Rs) calculation of solar panelsWith data logging/open function, the I-V curves of solar system can be analysed / recorded for a period of time (e.g. 60 min.)Conversion of I-V curve under OPC to data under standard test condition (STC) based upon IEC standardProvide Operating Condition (OPC) and Standard Test Condition (STC) test reports for verification of solar panel performance (OK or NO OK)Users can set up the parameters of solar panelsUsers can set up the series number of solar panels. Parameters of many solar panels can be measured in one measurementThe Irradiances and Temperatures of solar panels can be continuously measured, monitored and recordedContinuously measure/monitor/record the DC power output of solar system and the AC power output of inverter (1 phase or balanced 3 phases)Calculate the efficiency of DC to AC power conversion and the efficiency of the max.output power

  • Low Power Programmable AC Source

    61600 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection

  • EDFA

    SPA-10G-32 - Hangzhou Softel Optic Co., Ltd.

    *Single/dual input for choice, built in optical switch for dual input, the switching  power can be set by thebutton in the front panel or by web snmp. *Output adjustable by buttons in the front panel or web snmp, the range  is down 4dBm *Max multi 32 port, with built in1310/1490/1550/1270/1577/WDM,max total output 38 dBm *Standard RJ 45 port for remote control, we can provide output contract and web manager for choice, and also plug-in snmp hardware can be reserved for update. *With laser key to turn on/off the laser.*With RF test function. *Adopts JDSU Pump laser*Led displays the working condition of the machine*Dual power hot plug power supply for choice, 90V~250V AC or -48V DC

  • Programmable/Direct Reading Attenuators

    ERAVANT

    Is a dual function direct reading and programmable rotary vane type attenuator for use in millimeterwave systems across the standard WR-03 frequency range of 220 to 330 GHz. The attenuator is an ideal piece of equipment in waveguide systems where a broad direct reading of attenuation is required. The default mode of operation is manual direct reading. In manual mode, the attenuation is adjustable with the large knob and the digital LCD screen displays the current attenuation value. The LCD screen is powered by an internal rechargable battery, which is charged via the 2.5mm DC jack by a provided DC to AC adapter. The 2.5mm DC jack also provides power to the stepper motor, encoder and internal microprocessor for the programmable mode function. The user can quickly switch to programmable mode by connecting the powered-up attenuator to a computer with the USB Type B port. In programmable mode, the attenuation is finely adjusted with a precision stepper motor by the internal microprocessor via user-entered serial port commands from the computer.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • PXI 8x4 1-Pole 10A Matrix With Loop-Thru

    40-551-101 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, this module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. This version of the 40-551 may be expanded to larger matrix sizes using cabling to daisy-chain the X and Y signals Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Digital Tesla Meter

    HT208 - Rinch Industrial Co.,Limited

    Model HT208 digital teslameter is controlled by the SCM,which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’sperson. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value,As mT or Gs unit of display can be change over,Measuring range of 200mT or 2000mT can be choosed,and others that as reseting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours

  • Test Compliance

    MX CTS Series - AMETEK Programmable Power, Inc.

    A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MXCTS System provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards. The MXCTS system offers many of the same features and capabilities of the California Instruments CTS Series product line already in use at many EMC labs around the world.

  • Portable Carrier Demodulator with Digital Display

    CD379 - Validyne Engineering

    The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.

  • Signal Splitters

    Becker Nachrichtentechnik GmbH

    Becker Nachrichtentechnik GmbH offers a comprehensive portfolio of active multicouplers and bi-directional signal splitters for duplicating RF signals from common sources. The multi-couplers are designed in 50 ohm technology and are available as a 19 ", 1 U devices as well as slot-in modules for our 'Modular RF Systems' platform. With help of the slot-in modules, larger scale distribution structures can be realized in a space-saving and cost-effective manner. Some devices are available in variants for AC or DC power supply and provide service-friendly remote monitoring capabilities. For use in the production of infotainment components special multi-couplers with integrated HF and DC test functions are available. The multi couplers are used in applications like radio monitoring and direction finding, in product development, validation, manufacturing, quality assurance and in the field of research.

  • Current Detectors

    PCE Instruments

    On our website you will find current detectors that are ideal for measuring AC or DC voltage. Current detectors are irreplaceable for inspection work and maintenance. We offer the following: voltage detectors, voltage leak detectors, voltage power detectors, Current clamps ideal for measuring AC or DC voltage. metric detectors, current detectors and more. These high quality current detectors include the capacity to measure many other parameters, such as capacity, resistance, power (both by way of clamps or by means of a hand held digital device with external clamps with a range of one or three stages). The current detectors are like the majority of our measurement instruments in that they meet and excel ISO standards. This calibration is done in a laboratory and comes with an accompanying certificate. All of our current detectors can perform the demanding tasks in each industrial sector regardless of the technical problem you encounter. If you can't find the current detectors you are looking for, please contact us and we will help you find the best solution to suit your needs by calling our offices on: UK customers +44(0) 23 809 870 30 / US customers (561) 320-9162 and our technical staff will advise you regarding our measuring instruments. Our engineers and technicians will be happy to help you with the current

  • Difference Amplifiers

    Analog Devices Inc.

    A difference amplifier is a special purpose amplifier designed to measure differential signals, otherwise known as a subtractor. A key feature of a difference amplifier is its ability to remove unwanted common mode signals, known as common mode rejection (CMR). Unlike most types of amplifiers, difference amplifiers are typically able to measure voltages beyond the supply rails, and are used in applications where large dc or ac common-mode voltages are present. They are ideal for current and voltage monitoring. Analog Devices offers a range of difference amplifiers, optimized for low distortion, low power, or high voltage performance.

  • Calibrating Equipment

    Meco Instruments Pvt. Ltd.,

    Stability DC : < 0.01 %FS / 3 min, AC : < 0.02 %FS / 3 minRipple : < 0.2 %Power Supply : 230 VAC, 50 (60) HzPower Consumption : < 250 VAOperating Temperature : 5ºC to 35ºCRelative Humidity : ≤ 80 %Distortion : < 0.5 %Display : 51/2 Digit LED Digital DisplayStep adjustment of Output Signal : 100 %FS / N, 10 %FS / N,%FS / N, 0.1 %FS / N (N = 4, 5, 6, 10 and 15)Dimensions : 190mm (H) x 480mm (W) x 545mm (D)Total Weight : 22.5 kgs (approx.)

  • Connection Devices

    Rockwell Automation

    Our Connection Devices include Network Media for Ethernet, ControlNet™, DeviceNet™, Power Media, and Safety Connection Systems. We offer many products for DC Micro (M12), AC Micro (1/2), MiniPlus (1, 1-1/8), Mini (7/8), Pico (M8), and M23: cordsets, patchcords, V- and Y-cables, splitters, field attachable connectors, and receptacles. Our I/O Wiring Systems include interface modules and cables that connect through pre-wired cables to digital and analog I/O. We offer several IEC and NEMA terminal blocks to meet your needs.