Filter Results By:
Products
Applications
Manufacturers
Coupling Decoupling Network
inject the disturbance signal. AKA: CDN
See Also: CDN, Conducted Immunity
-
product
Coupling Decoupling Network
TBCDN-M3
The TBCDN-M3 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Coupling Decoupling Network
TBCDN-M2
The TBCDN-M2 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Coupling Decoupling Network
TBCDN-M1
The TBCDN-M1 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Coupling Decoupling Network
TBCDN-M4
The TBCDN-M4 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.
-
product
Coupling Decoupling Networks (CDN)
Beijing KeHuan Century EMC Technology Co,.LTD
Beijing KeHuan Coupling Decoupling Networks (CDN)
-
product
CDN - Coupling / Decoupling Networks
The Coupling- / Decoupling Networks are used to inject common mode disturbances to Equipment under Test (EuT). Further the CDNs provide sufficient decoupling between Auxiliary Equipment (AE) and disturbance signal. The requirements for CDN and their application are described in the standard IEC 61000-4-6 (Immunity to conducted disturbances, induced by radio-frequency fields). CDNs have a common mode impedance of 150 Ohm and are available for a multitude of cable types and connectors.
-
product
Coupling Decoupling Network for Communication Lines
CDN61000-5C
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating voltage: Max 50V DC • Max operating current: Max 1A Related Instruments
-
product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
product
PXI Vector Network Analyzers
Our PXI vector network analyzers (VNAs) perform fast, accurate measurements and reduce your cost-of-test. Simultaneously characterize many devices — two-port or multiport — using a single PXI chassis. By combining independent, two-port network analyzer modules into one chassis your multisite, multi-DUT, and multiport test applications scale flexibly. Use all ports to simultaneously measure your devices with multiport error correction.
-
product
PXIe Vector Network Analyzer, 10 MHz To 44 GHz
M9837A
The M9837A PXI network analyzer (VNA) offers unrivaled performance for testing multiport, multisite, multi-DUT modulated signal measurement from 10 MHz to 44 GHz.
-
product
PXIe Vector Network Analyzer Source, 1 MHz To 6 GHz
M9389A
The M9389A PXIe vector network analyzer source is a component for the M9485A PXIe multiport vector network analyzer. The M9389A configuration includes two PXIe modules (M9310A source output, M9309A synthesizer) and its control is provided through the M9385A software front panel (SFP). The M9485A provides a true multiport VNA with up to 12-ports in one chassis and up to 24 ports in two chassis.
-
product
PXIe-S5090 2-Port 9 GHz Analyzer
PXIe-S5090
The PXIe-S5090 delivers metrology-grade VNA performance and speed to National Instruments’ PXI system. This high-performance vector network analyzer allows testing of two-port devices from the bench to the production floor in a compact, modular form factor. With 138 dB dynamic range and +13 dBm maximum power, this VNA is engineered for short time to first measurement and also for high performance automation with fast test times.
-
product
PXIe Vector Network Analyzer, 9 kHz to 6.5 GHz
M9801A
Full 2/4/6/ port VNA on a PXI module with flexible applications.
-
product
PXI Vector Network Analyzer, 9 KHz To 20 GHz
M9804A
Full 2/4/6/ port VNA on a PXI module with flexible applications
-
product
PXIe-S5090, 9 GHz PXI Vector Network Analyzer
787251-01
PXIe, 9 GHz PXI Vector Network Analyzer - The PXIe-S5090 is a 2-port Vector Network Analyzer (VNA) that helps you measure amplitude, phase, and impedance. You also can use the PXIe-S5090 to perform time-domain analysis and to calculate the S-parameters of 2-port RF devices. It features a 300 kHz to 9 GHz frequency range, a wide dynamic range, and high sweep speeds for automated design validation and production test. Additionally, the PXIe-S5090 supports automatic precision calibration, full vector analysis, and reference plane extensions.
-
product
PXIe Multiport Vector Network Analyzer, 1 MHz to 9 GHz
M9485A
1 MHz to 9 GHzUp to 12-ports in one chassis, 24-ports in two chassis Various applications - full N-port cal, FOM, Pulse, time-domain, noise figure and gain compression analysis capability Improve accuracy, yield & margins with the best PXI VNA speed, dynamic range, trace noise and stability Improve throughput with fast cycle time: 5 msec at 201 points, 2-port calVarious configuration with standard test set and configurable test set
-
product
PXIe Vector Network Analyzer, 300 kHz to 6.5 GHz
M9371A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
PXIe Vector Network Analyzer, 100 kHz to 44 GHz
M9807A
Full 2 port VNA on a PXI module with flexible applications
-
product
PXIe Vector Network Analyzer RF Distributor
M9340A
The M9340A PXIe vector network analyzer RF distributor is used in the M9485A PXIe multiport vector network analyzer. The module distributes the source and local signals from the source modules to the receivers.
-
product
PXI Vector Network Analyzer, 300 KHz To 4 GHz
M9370A
The Keysight M9370A PXIe vector network analyzer is a full two-port VNA that fits in just one slot. It can function as a two-port VNA, or with multiple modules can be configured for multiport or multi-site measurements.
-
product
PXIe Vector Network Analyzer, 300 kHz to 20 GHz
M9374A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
PXIe Vector Network Analyzer, 100 kHz to 53 GHz
M9808A
Full 2 port VNA on a PXI module with flexible applications.
-
product
PXIe Vector Network Analyzer, 300 kHz to 26.5 GHz
M9375A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
PXIe Vector Network Analyzer, 300 kHz to 14 GHz
M9373A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
PXIe Vector Network Analyzer Synthesizer: 187.5 MHz To 6 GHz
M9309A
The M9309A PXIe vector network analyzer (VNA) synthesizer is a component for the M9485A PXIe multiport vector network analyzer. Control the M9309A through the M9485A software front panel. The M9485A provides a true multiport VNA with up to 12-ports in one chassis and up to 24-ports in two chassis.
-
product
PXIe Vector Network Analyzer, 300 kHz to 9 GHz
M9372A
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
product
PXI Vector Signal Analyzer
Keysight's PXIe vector signal analyzers are ideal for design validation and manufacturing applications that require fast, high quality measurements where quality control, product conformance and test optimization are essential. With a small footprint, speed, scalability repeatability, and the flexibility to configure a solution with a shared processor, frame/chassis, display, and interface, PXIe vector signal analyzers provide the building blocks for your single or multi-channel modular test solution.
-
product
PXIe Vector Network Analyzer, 100 kHz to 26.5 GHz
M9805A
Full 2 port VNA on a PXI module with flexible applications.
-
product
PXIe Vector Network Analyzer, 10 MHz To 20 GHz
M9834A
The M9834A PXI network analyzer (VNA) offers unrivaled performance for testing multiport, multisite, multi-DUT modulated signal measurement from 10 MHz to 20 GHz.
-
product
PXIe Vector Network Analyzer, 9 kHz to 4.5 GHz
M9800A
Full 2/4/6/ port VNA on a PXI module with flexible applications.