Filter Results By:

Products

Applications

Manufacturers

Showing results: 286 - 300 of 301 items found.

  • Microohmmeter

    MMR-6700 - Sonel S.A.

    The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • Micro-Ohmmeters

    IBEKO Power AB

    Contact resistance measurement is one of the most important and common tests during switchgear manufacturing, commissioning and maintenance stages. Besides switchgear testing, the RMO digital micro-ohmmeters are designed for simple, safe and efficient testing of:disconnecting switches,high-current bus bar joints,cable splices,welding joints,and different high-current links in factory and high-induction field environments.All DV Power RMO micro-ohmmeters use Kelvin’s 4-point measurement principle which is the most convenient for very small resistance measurements. The measurements are accurate and in accordance with international standards for AC high-voltage circuit breakers testing (IEEE C37.09 and IEC 62271-100).Starting from 2003, DV Power has been a trend-setter on the market when our first 500 A micro-ohmmeter weighing only 8 kg (RMO500A / CPM500) was released.Currently, DV Power products portfolio includes 16 models, divided into 3 series:13 portable models: RMO-A (6) and RMO-G (7) series.6 handheld models: RMO-H (6) seriesThe instruments generate a user-selectable and ripple-free test current up to 800 A in an automatically regulated test ramp. Test current ramping significantly decreases the influence of the magnetic transients to measurement.

  • Protective Bonding Testers

    RMO-E Series - IBEKO Power AB

    The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E

  • Ground Grid Tester

    GGT Series - IBEKO Power AB

    The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Micro-Ohmmeters

    RMO-A Series - IBEKO Power AB

    The RMO-A is a portable micro-ohmmeter designed for contact resistance measurements of switchgear during manufacturing, commissioning and maintenance stages. This micro-ohmmeter is widely used by medium and high-voltage circuit breakers manufacturers. Other typical applications are testing of disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. It accurately measures not only in factory environments but also in high-induction fields and substationsThe RMO-A series contains 6 models, rated from 100 A (RMO100A) to 600 A (RMO600A). The RMO500A (formerly CPM500) is our best seller, with 500 A ripple-free current and weighs only 8 kg.Although placed in a very portable and lightweight metal housing, RMO-A micro-ohmmeters have very high output power capabilities. They can generate 600 A test current continuously for up to 20 s. You can test with current up to 100 A without rest time. High output voltage enables a wider measurement range at the highest test currents, as well as the use of thinner/longer test cables. For testing with 100 A, 20 m test leads can be provided with only 16 mm2 cross-section.RMO-A micro-ohmmeter generates a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the RMO-A ramps up with increasing current before measuring and decreasing current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.An additional option is a built-in High Precision module suitable for measurement of very low resistances, ranges from 1 to 30 µΩ, with 0,01 µΩ resolution.These instruments can store up to 500 measurements in internal memory. A built-in thermal printer is available as an option.Our free DV Win software communicates with the RMO-A micro-ohmmeters via USB or RS232 interface. It allows you to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.

  • Micro-Ohmmeters

    RMO-G Series - IBEKO Power AB

    The RMO-G is a portable micro-ohmmeter designed for contact resistance measurement of non-inductive test objects and applications with increased safety requirement. It tests medium and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. Due to its Both Sides Grounded and Remote Control functionalities, the instrument accurately measures even in the most demanding environments, providing additional safety to testing personnel.The RMO800G is the most powerful portable micro-ohmmeter on the market with 800 A output current. RMO200G is our best seller in the USA. A user can choose the appropriate model depending on the output current requirement, from 100 A (RMO100G) to 800 A (RMO800G).We use an unbreakable plastic case with IP67 protective rating (with closed lid) for instruments’ housing. Although very portable and lightweight, RMO-G micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents. Consequently, it enables the usage of thinner/longer test cables. RMO-G generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. During the testing, it increases current before measuring and decreases current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.Special current clamps measure a current through groundings when the instrument tests in Both Sides Grounded conditions. The instrument itself powers these clamps. If even higher safety level is required, the Remote Control feature enables the operator to perform measurements from distant locations.RMO-G instruments can store up to 500 measurements in internal memory. Also, they have a built-in thermal printer and USB flash drive available as an option. An additional option is the built-in High Precision module suitable for measurement of very low resistance, in the range from 1 to 30 µΩ, with 0,01 µΩ resolution.Our free DV Win software communicates with the RMO-G micro-ohmmeters via USB or RS232 interface. It allows a user to run the test remotely from a PC. Also, a user can download test results, analyze and generate fully configurable test reports through the software.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • Handheld Micro-Ohmmeters

    RMO-H Series - IBEKO Power AB

    The RMO-H is battery operated and handheld micro-ohmmeter. It is designed for a variety of applications for contact resistance measurement of non-inductive test objects. Typical applications are accurate testing of:medium and high-voltage circuit breakers,disconnecting switches,high-current bus bar joints,cable splices,and different high-current links.Even more, it accurately measures in high-induction filed environments and substations, as well as in factory testing.RMO-H Series contains six models in total, divided in 2 sub-series depending on the test leads length requirement and the battery type:RMO-H1, RMO-H2 and RMO-H3 models are intended for use with short cables (e.g. 1,3 m / 3 m / 5 m). The 1-cell Li-Po battery with 8200 mAh capacity provides output voltage up to 4,1 V DC.RMO-H21, RMO-H22 and RMO-H23 models are ideal for applications where test leads with lengths > 5 m are required. The high output voltage (up to 8,3 V DC) is provided by 2-cells 4100 mAh Li-Po battery.The test current is regulated and can be selected in a range of 1 A to maximum 300 A, depending on the maximum test current rating:RMO-H1, RMO-H21 models – up to 100 A DCRMO-H2, RMO-H22 models – up to 220 A DCRMO-H3, RMO-H23 models – up to 300 A DC.Unlike many other handheld micro-ohmmeters available on the market, our instruments have regulated and user-selectable test currents. Therefore, RMO-H instruments generate an automatically regulated test ramp with stable and ripple-free current during measurement. These revolutionary characteristics in a handheld micro-ohmmeters technology are possible by using sophisticated Li-Po batteries. Consequently, modern battery technology enables you to do multiple measurements, and a full day of testing without recharging the battery.With all RMO-H models, it is possible to make tests on Both Sides Grounded testing objects, in an increased safety environment. Finally, these features in combination with a user-friendly interface (1-click to measure) significantly speed-up testing procedure and make it safer.These instruments store up to 1000 measurements on the internal micro SD card.Our free DV Win software communicates with the RMO-H micro-ohmmeters via a wireless Bluetooth interface. Furthermore, it allows you to download test results, analysis and generate fully configurable test reports.

Get Help