Showing results: 2386 - 2400 of 2843 items found.
-
181 CB -
Standard Electric Works Co., Ltd
● The Amplifier Probe is designed to identify and trace wires or cables within a group without damaging the insulation.● Works with any Tone Generator to identify wires.● Volume control for increased sensitivity and adjustable to suit work environment.● Recessed ON/OFF button prevents battery drain.● A phone jack is designed for headset or handset.
-
179 CB -
Standard Electric Works Co., Ltd
● The Amplifier Probe is designed to identify and trace wires or cables within a group without damaging the insulation.● Works with any Tone Generator to identify wires.● Volume control for increased sensitivity and adjustable to suit work environment.● Recessed ON/OFF button prevents battery drain.● A phone jack is designed for headset or handset.
-
MC151 -
Powertek LLC
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
CVM-780 -
Eurostat Group
The CVM-780 contact voltmeter combines the ease of use of a digital voltmeter with the high impedance and low capacitance of a true electrostatic voltmeter, in a small, portable package.It reads the actual voltage, without interference from the electrostatic field strength. The ceramic tips of the probe allow precise measurement of values.Measurement of voltages up to 500 VDC.
-
Voyager M4x -
Teledyne LeCroy
The industry’s most accurate and trusted USB analyzer platform now supports USB 3.2, USB4 and Thunderbolt 3 testing and verification. The legendary Voyager family combines best-in-class probe technology with industry-leading analysis software allowing designers and validation teams to debug problems and verify interoperability for next-generation USB systems.
-
ROTO-SCAN -
Foerster Instruments, Incorporated
The fully automatic crack test system ROTO-SCAN was specially developed for the testing of rings. The mechanical equipment has been developed for the gentlest possible handling of the test pieces and features a compact and low-maintenance design. The test probes seamlessly scan the inner and outer contours of the test pieces, thus ensuring 100 % testing of the rings.
-
72-7715 -
Tenma
Compact handheld thermometer is ideal for a variety of industrial, residential, HVAC and equipment testing applications. It accepts a wide variety of industry standard thermocouple probes and features internal data logging of up to 100 records. Dual inputs allow simultaneous measurement of two separate zones with independent readout or differential (T1-T2) display
-
Vektrex Electronic Systems
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
CTRL Systems, Inc.
The CTRL UL101 Basic Kit includes attachments for airborne ultrasound applications including leak detection (any type of gas), vacuum leak detection, electrical inspection, and steam leak detection. Additionally, the kit includes a single 3-inch solid probe for diagnosing steam traps and valves by detecting internal by-pass leaks.
-
DS1000Z -
Rigol Technologies Inc.
The DS1000Z series of digital oscilloscopes use the Ultravision technology platform, which continues the characteristics of deep storage and high waveform capture rate, and has an excellent cost performance advantage. The innovative DS1000Z Plus series comes standard with a digital channel interface that can be upgraded to a full-featured MSO with the addition of an RPL1116 logic probe.
-
Star Trace (P) Ltd.
Digital Gauss meters are hand held devices which are used to measure D.C magnetic field using Hall Probes. The Gauss meter is available in two different ranges and helps in quick calibration. As the Digital Gauss meter is easy and simple to handle it is extensively used in industries which require measurement of magnetic field.
-
LED Test -
Columbia Elektronik AB
As the original inventors of light probes for in-circuit color and intensity test of LEDs, Optomistic Products has been a leader in LED test for over 20 years, providing LED solutions to customers world-wide. Our unique patented LED test solution offers unparalleled reliability and is widely accepted by the LED test industry.
-
Nanjing ELIKE Meter Co, Ltd.
Basic functions:AC current: 40/400/1000ADC current: 40/400/1000AAC voltage: 4/40/400/750VDC voltage: 400mV/4/40/400/1000VResistor: 400/4/40/400K/4/40MTemperature: -20 to +750°CFrequency: 10/100/1000Hz/10/100kHz/10MHzDuty cycle: 0.1 to 99.9%Capacitance: 5nF/50nF/500nF/5μF/50μF/200μFSpecial functions:Auto rangingNCVDiodeContinuity buzzerLow battery displayData holdRelative data holdAuto/manual range shiftZeroAuto power-offOverload protectionSampling frequency: 3 times/sMaximum display: 3999Maximum open distance of clamp mouth: 55mmGeneral characteristics:Color: iron gray and orangeNet weight: approximately 274gLCD size: 46 x 32mmSize: 245 x 90 x 33mmPower: 1 x 9V and 6F22Packing content:CartonHandheld bagEnglish manualTesting leadBatteryTemperature probe
-
SMP2 -
Wavecontrol, S.L.
2-in-1: broadband measurements (1 Hz - 18 GHz) and spectrum analysis (1 Hz – 400 kHz)Real-time FFT-based spectrum analysis using digital processing.Weighted Peak Method (WPM) for automatic and real time comparison with limits.Special auto-gain function for peak detection (indispensable for procedures such as welding).Display of results in RMS and peak values.Function for time domain measurement of a specific frequency.Automatic field probe recognition.E&H field selection.Total field value and value for each component (X, Y, Z).Frequency SPAN selection.High Pass Filters at 1 Hz, 10 Hz, 25 Hz and 100 Hz.Max-hold function.Display of maximum, minimum and average
-
Helmut Fischer AG
Maximum safety with high voltage generation directly in the probe head and low-energy voltage according to ISO 2746Three instrument versions with different test voltage ranges:HV5: 0.8 5 kVHV20: 4 20 kVHV40: 8 40 kVIntuitive operation with menu navigation, rotary push switch and OLED displayExtensive selection of electrodesDisplay of the test voltage applied directly to the electrode Pore detection sensitivity: detection threshold settable to a voltage drop of 10, 20, 30 or 50 %Porosity detector switchable between static and dynamic thresholdBattery operation by means of a Li-ion battery with smart battery technology, a controller monitors the battery state permanently and avoids deep discharge