Showing results: 1306 - 1320 of 2843 items found.
-
PP008-1 -
Teledyne LeCroy
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
WS-3000 -
NAPSON Corp.
*Automatic probe head selection(exchanger) among 4 kinds of probe head*[No need to exchange a probe head by each different sample measurement]*Edge 1mm measurement is available by dual meas. mode*High cost performance from high speed measurement*FOUP compatible, GEM / SECS compatible
-
784255-01 -
NI
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
CP500 -
Teledyne LeCroy
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
784257-01 -
NI
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
784256-01 -
NI
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
781785-01 -
NI
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
783630-01 -
NI
The SP500C, or Multi-Contact Isoprobe IV - 100:1, is a standard passive probe with fixed 100x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
783629-01 -
NI
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
784253-01 -
NI
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
784254-01 -
NI
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Extech PQ3350-3 -
Extech Instruments Corporation
Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.
-
Extech PQ3350-1 -
Extech Instruments Corporation
Complete with 1200A 12" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case
-
RP4030 -
Teledyne LeCroy
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
RP2060 -
Teledyne LeCroy
+/-60V offset permits the DC signal to be displayed in the vertical center of the oscilloscope grid with a high-sensitivity gain setting (maximum +/-800mV dynamic range).