Showing results: 391 - 405 of 989 items found.
-
PROMAX Electronica
An efficient way to prevent faults in circuits or facilities by locating hot spots, as well as in veterinary medicine or location of living beings.
-
ETDR 10A-2 -
Elektronika
Compact dual channel precision full function portable easy to useTDR for fault location on balanced loaded and unloaded cables.
-
ETDR 10A-C -
Elektronika
Compact dual channel precision full function portable easy to useTDR for fault location on balanced loaded and unloaded cables.
-
ELQ 30A+ -
Elektronika
200 Hz to 35 MHz selective/wideband Level Meter & Generator, with Spectrum Analyser with Z/RL/LCL and Fault Locator Bridge
-
OTM-XB -
Zensol Automation Inc.
The OTM-XB is the only standalone recorder to use the vibro-acoustic method that detects intermittent and sporadic operational faults on working circuit breakers.
-
A994 -
AGM Elettronica
The A994 is an open circuit locator for electric and telephone cables wind on the reel; it gives the position of the fault from the inside or outside end of the cable, in percentage to the total cable length. The instrument measures the ratio of the capacitances of the two sections of failed conductor using two high precision i/v converters. The advantage of this method is due to the fact that the measurement error depends almost exclusively on the dimensional inhomogeneity of the cable. The A994 has the unique feature to permit the location of fault in cables with all broken wires. This instrument locates breaks in cables with a total capacity between 2 nF and 5 uF. The distance to fault is displayed on a large LCD display.
-
Teledyne Paradise Datacom
Teledyne Paradise Datacom’s Indoor Rack Mount (R) series SSPAs achieve the highest power density in the industry along with enhanced maintainability. Local, front panel, control is available with a user friendly touchscreen interface. Five fault condition indicators on left side of the front panel reflect some of the SSPA major faults states, plus a summary fault indicator. The SSPA online indicator turns green when the amplifier is in Online mode (1:1 Mode) or serves as an AC power indicator in standalone mode. Local/Remote and Mute/Unmute indicators show the current control mode and mute state of the amplifier.
-
CFL PL4 -
Scope T&M Pvt, Ltd.
CFL PL4 Power Cable Fault Locator is a portable, easy to use cable fault pre-location instrument. It uses the Time Domain Reflection (TDR), Secondary Impulse Method / Multiple Impulse method (MIM) and Impulse Current Method (ICM) on low, medium and high voltage cables. Its measuring ranges enable pre-location on cable lengths from 500 m to 64km.
-
M60 -
GE Digital Energy
The M60 Motor Protection System offers comprehensive protection and control solutions for medium to large sized three phase motors. The M60 includes advanced automation and communication capabilities, extensive I/O options, and powerful fault recording features that can simplify postmortem fault analysis and help minimize motor downtime. As part of the UR Family, the M60 provides superior protection and control.
-
ELQ 2+ -
Elektronika
2,2 MHz Test Set for the qualification of ADSL & SHDSL lineswith data rate calculation. TDR & Bridge for cable fault location.
-
-
Schweitzer Engineering Laboratories, Inc.
Motor protection products and systems provide complete protection for all types of motor faults. They are suited for use in industrial- and commercial-scale facilities.
-
HVA Series -
b2 High Voltage
HVA systems detect faults in cable networks in a non-destructive yet efficient way and fulfill all the requirements of modern cable testing.
-
RCD -
E-Max Instruments
The RCD is a carrier signal demodulator for SCADA and Fault Data Recording. the RCD demodulates the carrier to indicate the presence of a relative level of a singal
-
Megger Group Ltd.
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.