Filter Results By:

Products

Applications

Manufacturers

Showing results: 466 - 480 of 531 items found.

  • Insulation & Multifunction Tester (LCD Display)

    1152 MF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Insulation & Multifunction Tester (LCD Display)

    1155 TMF - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.

  • Motor/Generator Test Equipment

    IBEKO Power AB

    Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.

  • Battery Voltage Recorder

    BVR Series - IBEKO Power AB

    Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.

  • High Voltage Op Amplifiers ≥12V

    Analog Devices Inc.

    High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.

  • HV Spark Gaps

    B-1015 - ROSS ENGINEERING CORPORATION

    *Spark gaps are enclosed in dust tight transparent enclosures with replaceable non-melting carbon spheres, up to 88kV PK.*Above 88kV, open style with hollow aluminum spheres is standard.*Applications for these units include over-voltage limiting, voltage measurement, capacitor discharge, and pulse forming.*Horizontal unit housings are removable.*Vertical unit housings are not removable.*Micrometer Vernier adjustment is standard for maximum accuracy on most models. Economy units without micrometer Vernier adjustment are available as an option.*Insulation to ground is available at standard and optional levels.*Spark gaps to 370kV, with motor operation available.

  • PMS Leak Test System

    UNION INSTRUMENTS

    The system (Pressure Measuring System) is a portable, complete system for leak tests. This consist of the pressure test kit PMS3000 for performing leak tests with an integrated graphic-capable 4.3” color touch display and a pressure relief kit DAK2000 for discharge test according to W400-2, Part 16 pressure loss methods as well as DIN EN 805. The system is complemented by a variety of connection accessories like the rugged accessory case (individually equipped), the test standpipe PSR and accessories for building gas connection as well as the electronically controlled test pumps EPP and the compact air compressor KLK1030.

  • Power ICs - Smart Load Switches

    Vishay Intertechnology, Inc.

    Combining multiple functions in a single IC, Vishay smart load switches eliminate the need for external circuitry . A simplified GPIO interface allows for power distribution and sequencing of multiple sub-systems. Slew-rate-control devices provide a controlled supply ramp to reduce inrush current, while fault protection and isolation switches increase robustness with reverse current, overtemperature, current limiting, and short circuit protection features. The ICs offer quick output discharge and small footprints, while their integrated design saves PCB space compared to discrete solutions, reduces BOM counts, and lowers manufacturing costs.

  • Digital (1kV below) Insulation Tester

    1651 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● ACV auto-detection function on 3 insulation ranges (250/500/1000V) and low Ω ragne before pressing the TEST button.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.

  • CATx Surge Protector

    SP-CAT5-6V - Network Technologies Inc

    Protects sensors running on CATx unshielded twisted pair (UTP) cable against the effects of electrostatic discharge, faulty wiring and lightning. The use of two protectors on each end of the line will provide increased protection for each end against surges. Protected pins: (1,2) (3,6) (4,7) and (7,8) pass through. Impedance: 85 to 115 Ohms. Surge suppression: 22Vpeak @ 100A 10/1000µs. Maximum continuous voltage: 6Vpeak. Dimensions WxDxH: 1x3.6x0.9 in (25x91x23 mm). Regulatory approvals: GR 1089, NEC 800.100 and 830.100, ITU 703, UL94 V0 Flame Rated.

  • Surge Generators

    K&S Engineering and Scientific Ltd

    The instrument is fully enclosed in a robust all steel enclosure mounted on castors and fitted with carrying handles. The control panel forms the top of the case, it is finished in high gloss light blue stoving with cutter engraved labelling, and is protected by a detachable lid. The EHT outlet is of a recessed type designed to prevent accidental contact with high voltages. Surge repetition is electronically controlled from 0 to 10 seconds, a single surge or a train of pulses can be selected by a panel mounted switch. Automatic discharge of the instrument is achieved by a gravity operated switch which is released on switching 'OFF' the instrument or on disconnecting the supply.

  • Multifunctional Safety Tests

    LXinstruments GmbH

    Manufacturers of electrical or electronic products are required by law to carry out an electrical safety test before placing them on the market. This final test takes place at the end of the manufacturing process and is therefore also referred to as an EOL test (end-of-line). Depending on the prescribed standard and directive, the following parameters are tested:- Leakage current and discharge current- Insulation resistance or the insulation strenth- Dielectric strength or electric strength- Correct installation of the protective conductor (ground continuity and ground bond test)- Faultless functioning of the product under the conditions defined for intended use (function or run test

  • 76kWh Lithium Battery 384V 200AHSolar Energy Storage LiFePO4 battery System

    SPVLI-76KWH - Zhejiang Sandi Electric Co., Ltd

    SANDI ESS lithium battery system is composed of lithium battery modules, BMS system, PV charge controller, AC/DC Charger, central control unit CCU, temperature detector, integrated structure and other parts; the solar panels in the system are battery storage and power for output; BMS module completes the detection and control of voltage, current, temperature, SOC, SOH and charging and discharging related parameters of power battery pack; PV controller and inverter realize bidirectional AC/DC function to meet the charging and discharging conversion demand of power battery pack; each detector is used to monitor the ambient temperature in real time to ensure the safety of the system.Features1. Standardized components, modular architecture, easy for expansion2. High energy density, small footprint, short construction period, strong environmental adaptability3. Battery module within the layered stack design, with more than 10 years of long design life4. Long Cycle Life LiFePO4 Lithium ion Battery system from 20KWH-500KWH optional5. The use of international advanced Mitsubishi IPM module and intelligent power module, with high power fast adjustment capability6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system8. Product communicates with the monitoring platform in real time through RS232, CAN communication interface, and reports various records in time to ensure real-time monitoring of the battery pack of the monitoring platform9. PV charge controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of PV modules and batteries10. Colorful LCD display all module working information and statusSpecificationModel SPVLI-76.8KWHType of cell LiFePO4 (Lithium iron phosphate)Battery configuration 3.2V 200AH 120PCSRated capacity (KWH) 76.8kwhNominal capacity (AH) 200AHNominal voltage (VDC) 384VOperating voltage range (VDC) 312-438VRecommended Charge Voltage (VDC) 420VRecommended discharge cutoff voltage (VDC) 360VRecommended charge current(A) 100AMax Charge Current (A) 200ARecommended discharge current (A) 100AMax Discharge Current (A) 200ACharge temperature range 1~45℃Discharge temperature range -10~45℃Solar Charge Controller InputMaximum. Input voltage of solar array(Vdc) <750VdcBattery system voltage 384VDCMaximum power of solar array 40KWMaximum charge current(A) 100AEqualization charging voltage (Vdc) 426VEqualize charging recovery voltage (Vdc) 405.6VOver voltage disconnect voltage (Vdc) 438VOver voltage recovery (Vdc) 432VWorking temperature -20~50℃Protection level IP20Communication interface CAN2.0, BMSDisplay 5" LCD, EnglishCooling system Fan coolingWorking Altitude (m) ≤3000mReference Weight (Kg) 920KgReference size (W*D*H mm) 900*1100*1700mm

  • Electromagnetic Pulse

    EMP - Keystone Compliance

    An electromagnetic pulse (EMP) is a short burst of electromagnetic energy that can be extremely damaging to electronic equipment. EMP energy can be transferred in the form of electromagnetic radiation, an electric field, electrical conduction or a magnetic field. Since EMPs have a short duration, their impact can occur across large ranges of frequencies. EMPs can be produced naturally, occur from man-made equipment. Natural EMPs include lightning strikes and electrostatic discharges (ESD), geomagnetic storms/coronal mass ejections of solar origin. Man-made EMPs include power line surges, pulses created by ignition systems, nuclear electromagnetic pulses (NEMP) and non-nuclear electromagnetic pulses (NNEMP).

Get Help