Showing results: 121 - 135 of 533 items found.
-
TEM -
Mess- & Prüfsysteme GmbH
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
GTPD-92 -
Kingrun Instrument Co., Ltd.
Partial discharge(PD) is a pulsed discharge that produces a series of physical phenomena and chemical changes such as light, sound, electrical and mechanical vibrations in and around electrical equipment.
-
STVHF/STVHE-A -
HK Film Capacitor Ltd
For High Pulse / High Energy Discharge applications with low discharge repetition rate, please tell more about your application. We might have a suggestion.
-
-
Kleinwächter GmbH
Electrostatic discharge is now a problem in many workstations, as modern microelectronics (integrated devices) are susceptible to damage caused by electrostatic discharge. However, other industries, such as telecommunications, plastics and explosive industries, are also severely affected.
-
PRODIGIT Electronics Co, Ltd.
*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.
-
Ametek Brookfield
Delivers quick and easy analysis of powder flow behavior in industrial processing equipment. It is ideal for manufacturers who process powders daily and want to minimize or eliminate downtime and expense that can occur when hoppers discharge erratically or fail to discharge altogether.
-
miniMasterCharger -
JFM Engineering
The miniMasterCharger is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.With its multiple modes of operation of Constant Current Charge (dual and single rate), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis), Resistance Discharge (analysis) and Full Discharge (deep cycle), the miniMasterCharger can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and Overvoltage conditions.
-
BLUe -
Scope T&M Pvt, Ltd.
BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.
-
Holding Informtest
Provides the. capacitance to be measured at a frequency which is reciprocal to the. product of the discharge resistance and the measured capacitance.
-
ER-X Series -
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy cleaning, discharge needle air barrier design to reduce contamination of the needles, replaceable discharge needle unit for easy maintenance, and a dual head configuration for enhanced charge area and layout (2 different ionizer heads can be connected to a single controller).
-
AQUILA -
Altanova Group
A compact and portable Partial Discharge acquisition unit, which allows to detect and analyze partial discharge activities in all electrical assets: from power cables to transformers, rotating machines and switchgears, together with the right combination of sensors and accessories. AQUILA comes with a full range of options, ideal for field testing.
-
700 -
Micro-Measurements
A battery-operated capacitive discharge spot welder for attaching and wiring weldable strain gages and temperature sensors.
-
MODEL 901HS -
TREK, INC.
Diagnostic Tool for Manufacturing Environments Sensitive to Electrostatic Discharge - Including Electronics, Semiconductors & Medical Devices. Model 901HS is a diagnostic tool used to identify incidents or verify suspected areas of ESD activity. A voltage sensitive antenna on the unit can be positioned in ESD sensitive environments to detect problem areas of electrostatic discharges.
-
PDIV 500-T -
Shanghai Dean Electrical Co., Ltd
Differing from partial discharge with high frequency pulse which produce sound and light phenomenon, the power frequency AC voltage reaches a certain threshold, can only produce instantaneous current leakage around the tested sample, it can be detected through discharge capacity (unit: PC) to evaluate partial discharge phenomena..The instrument PDIV 500-T is designed to put samples such as enameled wire, insulation paper/film, and electric motor stator in the High temperature / humidity environment chamber, applying a power frequency voltage with a programed rising speed, and prefect ground connection must be guaranteed , through the coupling capacitor as the medium, the continuous detection of discharge capacity against the voltages will create formulation between the Voltages and discharge capacities (pc), the software will find the discharge voltage threshold called PDIV.