Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
Calibration Baths
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
product
Calibration Baths
Calibration baths are electronic controllers which automatically, quickly and with the help of a liquid supply a temperature Due to the high reliability, accuracy and exceptional homogeneity in the measuring chamber, calibration baths are particularly suitable as a factory/working standard for the automatic testing and/or calibration of the widest range of temperature probes − independent of diameter. A special micro calibration bath design enables on-site applications.
-
product
Portable Calibration Baths
6109A / 7109A
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
product
Blackbody Sources
Hyperion R Model 982
The Hyperion R Calibration Bath comprises a blackbody cavity for calibration of infrared thermometers. An important factor is that its operation range includes ambient temperature, which is a difficult radiation point to achieve.
-
product
Temperature probes
Industrial platinum resistance thermometers 935 are suitable for use in the laboratory or on site. They can be used as a standard work on an oven or a calibration bath or as a precision sensor for our temperature indicators thermometers.
-
product
Liquid Calibration Baths
Designed for calibration of temperature control devices that contain hazardous or corrosive fluids. Meets Class 1, Division 1 requirements for operation in a hazardous environment. CSZ explosion proof liquid calibration baths are designed to calibrate a large number of temperature sensors which contain a variety of different types of hazardous fluids. The sensors are typically calibrated in the same fluid used in the sensing element of the control devices per specification.
-
product
Temperature Calibrators
AMETEK Sensors, Test & Calibration
Our dry-block and liquid bath temperature calibrators include 6 series with more than 25 models and temperature ranges from -100 to 1205°C. All feature portability, accuracy, speed, and advanced documenting functions with JofraCal calibration software. Our calibrators include the smallest and coldest dry-block calibrators available.
-
product
Reference Thermometers
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
product
Temperature Standards
ITS-90
The defining instruments of the ITS-90 (International Temperature Scale of 1990) are Standard Platinum Resistance Thermometers (SPRTs) and ITS-90 fixed-point cells. SPRTs are calibrated in fixed-point cells to provide the highest possible temperature accuracy. Primary standards offered by Fluke Calibration include: long-stem SPRTs; capsule SPRTs; triple point of water cells; metal fixed-point cells; maintenance baths and maintenance furnaces for fixed-point cells; standard resistors.