780 MCA Family -
CAEN S.p.A.
The 780 MCA family integrates advanced firmware algorithms operating Digital Pulse Processing for Pulse Height Analysis (PHA). The processing algorithms can be easily adapted to different detectors and application ensuring effective data analysis even at high count rates. It provides advanced tools for configuring baseline restoration, pile-up rejection. Thanks to the two input simultaneous acquisition, the modules are able to manage coincidence and anti-coincidence logic between detectors, allowing the user, for example, to easily take advantage of background rejection or anti-Compton techniques. These MCAs may provide at the same time energy, time stamp and the digitized pulse in a configurable time window (e.g. including the rising edge region) in order to perform further online analysis. Acquisition settings and basic mathematical analysis are performed through the CoMPASS and MC2Analyzer software, providing energy spectra with up to 16k channels, which can be exported and imported in ASCII or N42.42 compliant files. CAEN further provides drivers for the supported communication interfaces; configuration software tools, C and LabVIEW libraries (CAENComm, CAENDigitzer, CAENDPP), demo applications and utilities.
-
DT5770 -
CAEN S.p.A.
The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.
-
MVNA-8-350-4 and 4S -
AB Millimetre
The microwave part MP-8-350-4 is designed for the 4S-Parameter measurements. It includes two connectors for the two detectors HM like in MP-8-350-2, and also two connectors for the two sources HG, which are powered alternatively.
-
KM 2100 / KM 2200 -
Kusam Electrical Industries Limited
• Volts / Amps. / Hertz, Dips & Swell, Power / Energy, Unbalance, Monitor, Scope, Harmonic, Logger & Interruption functions. (KM 2200)• Inter Harmonics, Transient Voltage, Inrush Current, Flicker function not available in KM 2200.• Frequency upto 400Hz (KM 2100); 50 / 60Hz (KM 2200)• Single-phase 2W / Single-phase 3W / 3-phase 3W / 3-phase 4W.• Flash memory 128MB• TF Card 8G Memory Card for long-term measuring data storage. • Support USB port to connect to PC and analyze the data / screen shots copied by U-disk.• Support LAN port to make the remote control available, transfer the measuring data.
-
Rapidox 2112 -
Cambridge Sensotec Ltd
The Rapidox 2112 Multiplex is housed in a 19″ rack mount unit and allows a programmed sequence of gas samples to be fed to a single gas analyser, thus saving money and space requirements.
-
Model N200 -
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.
-
Model T100 -
Teledyne Advanced Pollution Instrumentation
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon 'kicker' and advanced optical design combine to prevent inaccuracies due to interferents.
-
Model N200M -
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
Model N100 -
Teledyne Advanced Pollution Instrumentation
The Model N100 instrument uses the proven UV-fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Sulfur Dioxide (SO2) gas.
-
Analyzer -
iSYSTEM ag
One of the most effective debugging techniques in embedded development and testing is tracing. Tracing means recording microcontroller activity, such as Program or Data flow.
-
ScanExpress JTAG Debugger -
Corelis, Inc.
Test probe access is a luxury—modern electronic system design techniques such as blind and buried vias or ball-grid-array (BGA) devices guarantee limited signal access. Test points quickly reduce precious board real-estate and can even degrade performance. ScanExpress JTAG Debugger overcomes these limitations to provide the control and visibility necessary to quickly debug and test hardware, using a simple JTAG port to interface with IEEE-1149.1 compliant devices.Whether debugging prototype hardware, enhancing production tests with boundary-scan control, or diagnosing a faulty board in the field, ScanExpress Debugger’s easy-to-use and versatile interface helps engineers test and debug systems faster and more efficiently.
-
Schwarzbeck Mess Elektronik
The FSHPH is a passive, single-axis H-field probe suited for non-ionizing radiation measurements. The FSHPE allows a fast and accurate safety-evaluation of the measurement environment.
-
-
LOG Storm -
Byte Paradigm
Logic analyzers are key tools for that process – they offer visibility over what happens in your digital electronic system.
-
780935-01 -
NI
The PCIe‑GPIB+ combines an IEEE 488 controller and an analyzer on one device for computers with PCIe slots. You can use this device to integrate an instrument into your system using GPIB as well as to troubleshoot and solve GPIB hardware and software problems. The PCIe‑GPIB+ achieves maximum IEEE 488.2 transfer rates. With an onboard bus master DMA controller, there is no microprocessor interruption in data transfers. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.