Showing results: 256 - 270 of 472 items found.
-
Frequency to Voltage -
Encore Electronics, Inc.
Encore Electronics offers a complete line of frequency to voltage converters ranging from the economically priced and compact DIN rail mounted Model FL228 to the rack mounted Model 225. For applications requiring performance between these two models, we now offer our FL236 DIN-rail packaged Digital Frequency/Voltage converter, featuring fast response time, low power and compact footprint.
-
Insight Product Company
Insight Product Company offers high-speed switching diodes with switching time up to 2 nsec and operating frequency range up to 140 GHz. Silicon p+-p-n-n+ high-speed switching diodes are designed to be used in mm-wave switching devices, phase changers, modulators, attenuators for the millimeter wavelength range. They are fabricated in the metal-ruby packages with hard-lead carrier (diameter 3.0 mm, 1.5 mm).
-
NI
Oscilloscope Devices are flexible, software‐defined instruments that are versatile enough for both time‐ and frequency‐domain measurements and are offered in industry-standard form factors like PCI and USB. They feature up to eight channels that can sample at speeds up to 2 GS/s. The devices also feature numerous triggering modes, deep onboard memory, and driver software API that includes data streaming and analysis functions.
-
Synchronous Accumulation (Order Analysis) -
ZETLAB Company
Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.
-
MS 1830 -
Meltronics Systemtech
- Configurable Frequency Ranges from 100Hz to 1MHz- Resolution insteps of 0.03Hz- Duty Cycle 50%- Amplitude of the Digital Frequency out : Low – 0.4V max, High – 4.8V min- Rise/Fall Time (for a 15pF Load) is typically 5 ns- Amplitude of the Analog waveform out : Low – 0.4V max, High – 4.8V min- Sinusoidal or Square Wave Output (Configurable)- Differential / Single Ended Output (Configurable)- Frequency on each of the 8 Channels are individually Programmable- Hot Swap Facility for live insertion and removal of the board- Facia plate with Micro Switch Assembly, provided for proper insertion / easy removal of the Board- BNC Connector Interface for Signal Output at the front panel- Each Output Channel is driven by a Cable Driver to drive 8m of Coaxial Cable- Driver interface for Windows XP/VISTA/7 and LINUX OS
-
Ametek Scientific Instruments
The Materials Lab XM product provides a fully integrated reference grade time domain and AC measurement platform. No need to switch sample connections between techniques. Time domain measurements include I-V (current voltage) characterization as well as fast pulse techniques. AC testing techniques include everything from single-sine analysis, to multisine / Fast Fourier Transform for faster low frequency analysis, to harmonics and intermodulation for testing linearity and breakdown of materials. Measurements of electrical impedance spectroscopy (EIS), admittance, permittivity and capacitance are all provided from the XM-studio MTS software platform, together with integrated equivalent circuit analysis functionality.
-
PA-699 -
PINTEK Electronics
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
COMM-connect
The SafeOne is a RF Safety Monitor covering the requirements set forth in WHO ICNIRP specifications. It has a very wide frequency range covering 30MHz to 10GHz, which makes it suitable for use in almost all antenna installations. Due to the innovative lightweight design, technicians can wear this at all times, without the need to constantly be observant of the state of the instrument. The SafeOne is powered with standard batteries, with 250 days of continuous operation.
-
ZND -
Rohde & Schwarz GmbH & Co. KG
The R&S®ZND network analyzer performs unidirectional measurements up to 4.5 GHz in the base model. It can be expanded to perform bidirectional measurements and the frequency range can be extended to 8.5 GHz. The large R&S®ZND touchscreen is easy to operate making it ideal for S-parameter measurements, even when many diagrams are needed. Time domain measurements can also be added for even more functions.
-
NI
Digitizer Adapter Modules for FlexRIO can be used with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO to create a high‐performance instrument with customizable firmware. With sampling rates from 40 MS/s to 3 GS/s and up to 32 channels, these modules cover a wide range of requirements for both time- and frequency‐domain applications. Digitizer adapter modules also provide digital I/O capability for interfacing with external hardware.
-
Monitran Ltd.
Monitran General Purpose Analysis Sensors are ideal for use with portable and on-line vibration analysers, providing the user with a complete spectrum of vibration intensity against frequency. Changes in this spectrum allow the user to determine the health of the machinery to which the sensor is attached. Most analysers will store the spectral values and monitor changes over a period of time, allowing prediction of expected component life and enabling efficient planning of maintenance schedules.
-
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
Keysight Technologies
Generate trusted microwave signals: get metrology-grade frequency & level accuracy with excellent distortion & spurious characteristicsRely on the highest quality signals from pure CW tones with 1 W of power to complex, vector-modulated signals with 4 GHz bandwidthReduce the time you spend on signal creation with Signal Studio softwareTake advantage of increased performance, flexibility & speed when you replace a legacy source with the code-compatible PSG
-
N8487S -
Keysight Technologies
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
N8481S -
Keysight Technologies
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.