Showing results: 301 - 315 of 472 items found.
-
PSELab -
Power Spectrum Estimation Laboratory
"PSE Lab" is a freeware Windows application useful to estimate power spectrum and time frequency distribution of signals. To estimate power spectrum, the application uses following methods: periodogram; using the simplex algorithm to estimation of complex exponential model optimal parameters; using the quasi-Newton algorithm to estimation of complex exponential model optimal parameters; least squares Prony method; modified least squares Prony method; Burg method; modified covariance method; MUSIC..
-
SME1203 -
Scientific Mes-Technik Private Ltd
Single Phase , 3 kV Impulse winding testing Low inductance impulse test: down to 10 μH Low energy test without damaging the coil Fast detection of winding insulation at a speed of 5.5 Meas/sec 4 kinds of waveform comparison methods Up to 40 MSPS sampling rate 320×240 dot-matrix graphic LCD display Multi-trigger mode programmableVoltage, Time and Frequency measuring functions Direct display of comparison result
-
Insight Product Company
Insight Product Company offers a high-power synthesizer of pulsed signals. They are ideal for ESR, EPR, and DNP experiments. The synthesizer has a high frequency stability (10-6), and allows control over the duraction and begining time of pulses. The synthesizer also enables phase manipulation, where each pulse is shifted by 90 or 180 degrees relative to the previous pulse. In contrast with the PIN modulators and injection-locked power amplifiers this synthesizer has absolutely no residual signal in the "OFF" position.
-
732A -
B&K Precision Corporation
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 732A Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
735 -
B&K Precision Corporation
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 735 Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
N9915A -
Keysight Technologies
9 GHz max frequency Carry the world's most integrated handheld & micro; W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Calibrate simply with QuickCal
-
N9914A -
Keysight Technologies
6.5 GHz max frequency Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Calibrate simply with QuickCal
-
4112 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.
-
AWG18 -
APPLICOS
The AWG18 is an 18 bit Arbitrary Waveform Generator for high-speed / high resolution waveform generation. This module features two dedicated signal paths. A DC to 100 MHz path which is optimized for accurate time domain and frequency domain measurements up to 30 MHz. And a dedicated AC path optimized for signals between 10 MHz to 100 MHz. In combination with the built-in filters it features a typical harmonics level of better than -80 dBc for the whole range.
-
TH2638C -
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
TH2638 -
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
TH2638B -
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
TH2638A -
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
TCG 02-G -
Tekron International Ltd
The TCG 02-G is a highly accurate, full featured GPS and GLONASS (GNSS) clock. Offering multiple oscillator options, Time Code and Frequency outputs, it fits virtually any timing application. With enhanced cyber security features that support NERC CIP requirements, the TCG 02-G is designed for use in modern day smart grid / smart substations, electricity distribution, transmission, and generation protection. In addition industrial application systems and traditional substations are equally provided for. This master clock synchronizes multiple IEDs (Intelligent Electronic Devices) within a network, including protection relays, synchrophasors, event recording and remote telemetry units to enable accurate time stamping. The TCG 02-G is available as a base unit or with one of three expansion module options.
-
9363-LN-100 -
King Design Industrial Co., Ltd.
This tester is designed to assess the damage made to product packaging and internal objects caused from transporting environment; to discover the packaging flaw and product’s early failure from a long-term cumulative vibration fatigue; avoid man-made transporting damage and improve product’s reliability and quality of delivered products. With the use of high-performance foot absorber, the resonance effect to floor caused by the bounce test may be waived; and can reduce the pile’s destruction to industrial plants. Two displays can make comparative display on both frequency and rpm at the same time; thus no need to switch in order to read these two values. The dual-control mode of time accumulator and counter can avoid human error resulting from the conversion. Easy to operate; no need for complicate training program.