Filter Results By:

Products

Applications

Manufacturers

Showing results: 961 - 975 of 1211 items found.

  • Complete Set of 1200KV/2400KV/4800KV Impulse Voltage Generators

    Shanghai Launch Electric Co., Ltd.

    The series impulse voltage generators are used for the impulse voltage tests of lightning impulse full wave, lightning impulse chopping, switching impulse voltage wave and steep wave, so as to check the insulation performances.

  • Climatic Chamber

    Wewon Environmental Chambers Co, Ltd.

    Climatic chamber is designed to do high temperature & high humidity, high and low temperature, or temperature cycling test, Climatic chamber mainly used for quality checking and assessing their quality reliability and life test. ● The climatic chamber simulate a full range of temperature testing and humidity testing conditions.These chambers are designed for ease-of-use, reliability and performance and include many user-friendly features standard with your purchase for the best value in the industry. ● Climatic test chambers are able to provide rapid product temperature change rates and use varying levels of relative humidity to locate design problems prior to shipping your products, improving product quality and reliability. climatic chamber For conditioning of samples prior to testing. Climatic chamber also can be used for a variety of materials of high – low temperature alternating test. The test temperature, humidity, time can be programmed. Provides conditions of temperature form -70 degree to +150 degree and of humidity from 20% to 98%. ● This type climatic chamber use 16bit Industry-grade PLC, programmable controller to control the test temperature test, and recycle time, more excellent anti jamming, high reliability of the data. ● TEMI880 large color LCD touched screen temperature & humidity controller. Real-time display program running time, the number of segment, the remaining time, repeat frequency,can display experimental data, including the pre-set segment time, heating status, calendar time, etc; climatic chamber directly digital display. ● Climatic chambers apply controllable silicon step-less adjusting technology to adjust temperature and humidity test continuously and precisely, and without over heated as the PID adjusting function. ● The thermal insulation material between outside and inside for climatic chamber is high-quality ultra-fine glass fiber insulation cotton, good thermal insulation effectivity. Thermal insulation layer composed of flame fire PU + glass wool insulation (insulation thickness 10.0 cm)

  • Wound Component EST Analyzer

    19036 - Chroma Systems Solutions, Inc.

    The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1.

  • Electrical Test Calibrators

    Time Electronics

    The electrical test calibrators from Time Electronics are designed for rapid calibration of various electrical test equipment. Portable calibrators include the InsCal models for insulation tester calibration and the PatCal for calibration of portable appliance testers.

  • Instruments

    Shenzhen Zeus Information Technology Co., Ltd.

    Shenzhen Zeus Info Tech Co., Ltd. Instruments, motorcycle fuel pressure gauge, auto ignition coil tester, digital multimeter, circuit tester, automobile insulation resistance tester, voltage detector, etc.

  • High Voltage Tracking Resistance (HVTR)

    UL 746A - National Technical Systems

    The High Voltage Tracking Resistance (HVTR) test method is used to assess the susceptibility to tracking of insulating materials that are exposed to high voltages outdoors. Insulators installed in the open are often at the mercy of humidity. Their electrical insulation properties can deteriorate to such an extent as a result that tracking paths are formed on the insulator surface. This test determines the tracking resistance that defines the dielectric strength of the insulating material surface and the maximum allowable leakage current (tracking).

  • Micro CT

    LCT 6 - Shanghai Powoo Industry Develop Group Limited

    - suitable for a wide rance of current (1.5A~120A); - there are standard holes on the primary lead wire; therefore, can be fixed at the terminal of the electricity meters with standard bolts, which makes it both firm and convenient; - the primary lead wire is highly customer-tailored with more than 300 specifications; - encapsulated with epoxy resin to ensure strong insulation ability; - linear output current, high precision; - ABS anti-combustion plastic casing.

  • Current Transformer Loading Type

    LCT 2 - Shanghai Powoo Industry Develop Group Limited

    - suitable for a wide range of current (1.5A~120A); - there are standard holes on the primary lead wire; therefore, can be fixed at the terminal of the electricity meters with standard bolts, which makes it both firm and convenient; - the primary lead wire is highly customer-tailored with more than 300 specifications; - encapsulated with epoxy resin to ensure strong insulation ability; - linear output current, high precision; - AMB anti-combustion plastic casing.

  • Connector Block, 78-Pin D-Type, Female

    40-965A-078-F - Pickering Interfaces Ltd.

    The 40-965A-078-F connector block provides a simple method of connecting to 78-Pin D-Type connectors. The screw terminals use a rising cage clamp mechanism to minimize risk of copper strand breakage. PTFE cables are recommended for use with this connector block to maximize copper cross-sectional area and insulation properties. Connector blocks have higher losses than a cable connection and the breakdown voltage is controlled by clearances to the metal shell.

  • Waveform Recorder

    Memory HiCorder MR6000 - HIOKI E.E. Corp

    Waveform Recorder 200MS/s sampling. Fit up to 8 input modules for a maximum of 32 analog channels. Superior real-time recording. Intuitive operability with 12.1-inch touch screen. Capable of simultaneously measuring 16 channels of insulation data while maintaining its 200 MS/s speed, the MR6000 can measure high-speed, high-voltage signals in inverter performance testing more accurately and safely than ever before.

  • Pulse Holiday Detector

    NOVOTEST SPARK-1 - NovoTest

    Pulse Holiday Detector NOVOTEST SPARK-1 designed to detect pits, flaws, and holes in different non-metallic insulation coatings (such as polymers, epoxy, bitumen, etc.) and is mostly used for oil and gas metal pipelines and other objects. The device can be used while the pipeline construction, operation or service. Tested coating thickness is up to 12 mm. Such tests are needed to evaluate the oil and gas pipelines corrosion protection reliability.

  • Megohmmeters/Insulation Resistance Testers

    AEMC Instruments

    Full line of megohmmeters with test voltages 50V to 5000V. Capability to measure insulation resistance up to 10T. These rugged, weather resistant meters are accurate, reliable and built to perform. Battery, AC Powered & Hand-cranked models available.

  • Partial Discharge Tester

    GTPD-1 - Kingrun Instrument Co., Ltd.

    The GTPD-1 digital partial discharge tester is a mufti-function comprehensive intelligent diagnostic live inspection instrument. It can diagnose and test transformers, switches, GIS and cables on-line. It is a special instrument for testing and analyzing the insulation performance of power equipment.

  • TTC-1 Tracking Test Chamber

    TTC-1 - Lisun Electronics Inc.

    It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.

  • Ground-Fault Products for Solidly Grounded Systems

    Bender Inc.

    Ground-fault products are used to monitor grounded systems (ungrounded and grounded) for fault currents or residual currents. The sum of all conductors except the protective earth conductor is measured by means of measuring current transformers.In general, ground-fault monitors (RCM - residual current monitors) are used to send a message to the user even before reaching the shutdown threshold of the GFCI. Ground-fault monitors detect deteriorations of the insulation level at an early stage and in a reliable way.

Get Help