Showing results: 631 - 645 of 687 items found.
-
TE6-0717 -
Hangzhou Tonny Electric & Tools Co., Ltd.
*Used to detect voltage, power, ground and circuit integrity*LCD display provides a ‘no guess’ voltage value of the circuit*Backbit LED indicates Green for Ground or Red for Power*One hand free to jiggle wires, replace fuse or operate a switch*Surge protected circuitry displays 3 to 30V DC (± 0.3V accuracy)*Computer safe<10mA circuit draw for confident testing
-
Morris Products Inc.
Tests & troubleshoots voice communication for open circuits, shorts, miswires, reversals, and split pairsSHIELD detection tests a cable’s shield integrityEasy to read fault display and high speed testingDebug mode for detailed fault identification resultsNetworking Cable Tester has auto sleep mode and power off switch to decrease power consumptionBattery low LED indicator
-
TES Electrical Electronic Corp.
Capable of measuring earth voltage. Data hold function. Auto power off function. The timer operates automatically about 10 minutes with the "test button switch are pressed to keep the tester power on.
-
400XAC Series -
EEC
Our 400XAC Series AC Power Sources provides both 1Ø and 3Ø AC or DC power in a single box solution. If you need an AC Power Source with superior application flexibility, look no further than the EEC 400XAC. Ideal for both production and laboratory use, this 3 phase AC Power Source provides a unique feature set at a competitive price point. Our exclusive SmartCONFIG feature allows the 400XAC Series to switch from 1 phase to 3 phase power with the push of a button. This flexibility maximizes your investment while providing you the AC and DC power that your application needs. The 400XAC Series AC Power Source includes the following models: 430XAC and 460XAC.
-
-
-
GX6325 -
Marvin Test Solutions, Inc.
The GX6325 is 6U switching card with 75 SPDT Form C relays with a switching power rating of 60 W. Featuring the highest density available in PXI for this type of switch card, the GX6325 is suitable for all test applications requiring general purpose, low level switching.
-
779976-01 -
NI
The PCIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the PCIe-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
778858-01 -
NI
96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module—The PXI‑6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
778792-01 -
NI
The PCI-6509 can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is required for outputs. Using programmable power-up … states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the PCI-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
779975-01 -
NI
The USB-6509 is an industrial, bus-powered USB device that can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is … required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the USB-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
PXI-2564 / 778572-64 -
NI
16-Channel, 5 A, SPST PXI Relay Module—The PXI‑2564 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. Each relay is nonlatching with very low on-resistance and low thermal offsets. The PXI‑2564 is fully software programmable. With an efficient coupling of voltage/current capability and relay density, this switch module is ideal for switching medium‑ to high‑power signals and loads in military, automotive, or automated test applications.
-
785640-01 -
NI
8-Channel Temperature Input Device for FieldDAQ - The FD-11613 measures up to eight thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11613 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11613 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11613 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
785854-01 -
NI
The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.
-
786469-01 -
NI
The FD-11605 can measure up to eight channels with a voltage input range of ±60 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11605 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages of up to 1000 V. The FD-11605 has an ingress protection rating of IP65/IP67 (dust-tight and water-resistant),can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11605 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11605 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11605 is ideal for test cell and outdoor environments.