Showing results: 16 - 30 of 42 items found.
-
Junxy Energy
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
K-1000 Resisitive -
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
Ohm Loads Powertek Inc.
The AC SERIES load banks are designed for connection to any 120VAC or 240VAC single-phase, 120VAC/240VAC split voltage, or 120/208VAC three-phase WYE source. The AC SERIES is ideal for integration into racked test systems or benchtop testing of aircraft power inverters, small generator sets, UPS units and any other AC power source. These standard models are easily configured for other voltage and power ratings.
-
K-1000 Resistive/Capacitive -
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
K-1000 Resistive/Reactive -
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
Eagle Eye Power Solutions
The LB-Series AC Load Banks are designed for high power portable load testing of generators, UPS, and other critical AC power sources. Available models meet a range of voltages including but not limited to 208, 380, 440, and 480 VAC. Load power model options reach 1000 kW standard with other options available.
-
K-1000 Resistive & Inductive -
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
RCD -
Junxy Energy
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
K-1000 Rack Mounted -
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
RL -
Junxy Energy
Resistive & reactive load banks are able mimic motor loads and electromagnetic devices within a power system as well as purely resistive loads by offering the ability to set a specific power factor (pf). Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit. JUNXY has an extensive range of resistive & reactive load banks to simulate these types of loads on a power source and the transformers, relays, and switches which will distribute the power throughout your facility.
-
RLC -
Junxy Energy
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
cPCI 3U -
Kontron
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
cPCI Serial 3U -
Kontron
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
cPCI 6U -
Kontron
Load boards are essential in keeping any system in top running shape. As a full-system provider, Hartmann strives to not only provide the systems you need, but the supporting hardware as well.
-
Bloomy Controls, Inc.
Bloomy's 8-Channel Load Module provides isolated current and voltage measurements for eight on-board 5W loads or for eight off-board 120W loads. With built-in switching for calibration and fault injection, the module provides unsurpassed capability for Mil/Aero applications. The module also provides switching and connections to allow switching between a real load (e.g., actuator, valve, etc.) and the simulated load.