  • Digital Panel Meter

    MPF-5A - Chuan Sheng Electronics Co., Ltd.

    Mx-5A meter to provide power (Watt or Active Power or Re-active Power or Power Factor), high-precision measurement, display and remote communication capabilities.Additional purchase: 1 group of relay outputs, 1 analog output, an RS485 communication output (the Modbus RTU Mode) interface, so that can be installed in power management, remote input and output, alarm and variety of remote communication control the use of needs.120mm (D) is ideal for assembling in panels with limited penetration depth

  • Wireless Data Logger

    EVA100 - Advantest Corp.

    The new highly integrated measurement system "EVA100" is supporting Power Supplies, SMU( 4 quadrant DC Signal Measurement Units ), Pattern Generators, Arbitrary Waveform Generators, Digitizers and Oscilloscopes necessary for complete analog / mixed-signal / sensor / digital IC devices and Modules including Electronic Control Unit (ECU) for automotive evaluation and measurement.This new measurement system allows engineers quickly to build their own measurement environment without combining several standalone instruments.

  • Standard High Speed A/D Converters

    Analog Devices Inc.

    Analog Devices high speed A/D converters (ADCs) offer the best performance and highest sampling speed in the market. The product offerings include low IF A/D converters (20 MSPS to 125 MSPS), high IF a/d converters (125 MSPS to 1.3 GSPS), and wideband ADCs (>1 GSPS). The high speed a/d converter portfolio offers cost and performance optimized solutions for various applications such as communications infrastructure, electronic test and measurement, and aerospace and defense.

  • Cable Fault Testers

    Greenlee Tools

    *Compact and lightweight solution for underground cable testing*DC Hi-Pot test of de-energized, shielded underground primary cable*No external power required - self-contained 8kVDC voltage source*Can be used up to a distance of 1500 ft (457m)*Clear and simple test results - analog bar graph and indication of good or faulted cable*Safety feature - measures AC voltage before converting to a DC voltage tester*Lightweight, single hot stick operation for testing cable

  • ABex Current Sense Module for Six Channel UUT Supply Monitoring

    ABex TM-406 Current Sense - Konrad Technologies GmbH

    The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.

  • Software

    Digilent Inc.

    Digilent’s proprietary software solutions enable you to communicate with our system boards and a wide assortment of logic devices and use our available analog and digital test & measurement instruments. Refined by customer feedback for years, these powerful and FREE software applications allow you to fully customize your project, from creating and modifying designs for your system board to custom scripting of instruments for capturing, recording, analyzing, and generating mixed signal and mixed domain waveforms.

  • Generic RF ATE Test

    Data Patterns Pvt. Ltd.

    The Generic RF ATE is developed to test the Radar and Radar Subsystems. The ATE is primarily built using an instrumentation control, precision RF routing systems and rack mounted test instruments. Generic RF ATE system enables measurement of parameters of Radar equipment such as Local Oscillators, Waveform Generators, Up and Down Converters, Analog Receivers, Array Group Receiver Units, TR Modules. The ATE is configured to test the Radars upto 18GHz frequency range.

  • NI-9269, 100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module

    781098-01 - NI

    100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module - The NI‑9269 is a channel‑to‑channel isolated analog output module. The NI‑9269 adds channel‑to‑channel isolation for increased safety and improved signal quality. Channel‑to‑channel isolation is commonly needed for applications that have multiple electrical systems, such as automotive tests, or industrial applications that are subjected to increased noise and often contain multiple ground planes.

  • NI-9269, 100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module

    781098-02 - NI

    100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module - The NI‑9269 is a channel‑to‑channel isolated analog output module. The NI‑9269 adds channel‑to‑channel isolation for increased safety and improved signal quality. Channel‑to‑channel isolation is commonly needed for applications that have multiple electrical systems, such as automotive tests, or industrial applications that are subjected to increased noise and often contain multiple ground planes.

  • NI-5742, 16-Bit, 1 MS/s, 32-Channel Signal Generator Adapter Module for FlexRIO

    782865-01 - NI

    The NI‑5742 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs and general-purpose digital input and output lines for system stimulus and control. The NI‑5742 is ideal for applications requiring high-channel density and the power of a user-programmable FPGA. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the NI‑5742, you must pair it with a compatible PXI FPGA Module for FlexRIO.

  • NI-5741, 16-Bit, 1 MS/s, 16-Channel Signal Generator Adapter Module for FlexRIO

    782864-01 - NI

    The NI‑5741 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs and general-purpose digital input and output lines for system stimulus and control. The NI‑5741 is ideal for applications requiring high-channel density and the power of a user-programmable FPGA. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the NI‑5741, you must pair it with a compatible PXI FPGA Module for FlexRIO.

  • PXI-6143, 8 AI (16-Bit, 250 kS/s/ch), 8 DIO, PXI Multifunction I/O Module

    779063-01 - NI

    8 AI (16-Bit, 250 kS/s/ch), 8 DIO, PXI Multifunction I/O Module—The PXI‑6143 is a simultaneous-sampling, multifunction data acquisition device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. The PXI‑6143 is ideal for a variety of applications, such as high-energy physics, ultrasonic and sonar testing, ballistics and highly transient signals, and multiaxis control. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • Digital Panel Mount Load Cell Meter

    MODEL DPM-3 - Transducer Techniques, Inc

    The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.