Filter Results By:

Products

Applications

Manufacturers

Analog

representation of a signal that varies over an infinite range of values.

See Also: Digital


Showing results: 2611 - 2625 of 2923 items found.

  • NI-9223, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    783284-01 - NI

    ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.

  • NI-9223, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    781398-01 - NI

    ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9223 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9223: either four, 2‑position screw terminal connectors or four BNC connectors.

  • High-Definition Oscilloscope

    MSOS104A - Keysight Technologies

    1 GHz bandwidth (upgradable)4 analog plus 16 digital channels Capture a longer signal trace with 20 GSa/s max sample rate and 100 Mpts/channel of standard memory Get superior signal integrity with system ENOB of 7.8 bits and 10-bit analog-to-digital converter (ADC)Gain increased usability with the multi-touch supported 15 inch capacitive touch screen and solid state drive for fast boot and reliability Improve your testing with a wide range of protocol, compliance, and analysis software

  • 16-Channel 500kSa/s USB Modular Multifunction Data Acquisition

    U2354A - Keysight Technologies

    The U2354A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2354A to simulate simultaneous analog input acquisition.

  • NI-5734, 120 MS/s, 16-Bit, 4-Channel Digitizer Adapter Module for FlexRIO

    781659-04 - NI

    The NI‑5734 is a digitizer adapter module that, when combined with a PXI FPGA Module or Controller for FlexRIO, creates a high-speed digitizer that simultaneously samples four channels at 120 MS/s. You can use the NI‑5734 to do real-time processing and streaming of analog data with high-performance A/D converters. The NI‑5734 also includes selectable elliptic, Bessel, and bypass hardware filters. The Digitizer Adapter Module for FlexRIO is ideal for applications that require in-line data processing, high data streaming rates, and deployed high-performance solutions.

  • NI-5733, 120 MS/s, 16-Bit, 2-Channel Digitizer Adapter Module for FlexRIO

    781659-02 - NI

    The NI‑5733 is a digitizer adapter module that, when combined with a PXI FPGA Module or Controller for FlexRIO, creates a high-speed digitizer that simultaneously samples two channels at 120 MS/s. You can use the NI‑5733 to do real-time processing and streaming of analog data with high-performance A/D converters. The NI‑5733 also includes selectable elliptic, Bessel, and bypass hardware filters. The Digitizer Adapter Module for FlexRIO is ideal for applications that require in-line data processing, high data streaming rates, and deployed high-performance solutions.

  • PXIe-5186, 12.5 GS/s, 8-Bit Digitizer

    782058-01 - NI

    PXIe, 5 GHz, 12.5 GS/s, 8-Bit PXI Oscilloscope—The PXIe‑5186 high-speed PXI oscilloscope has two channels with flexible settings for coupling, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require up to 5 GHz of analog bandwidth and flexible measurement configurations. The PXIe‑5186 also features PXI synchronization and data streaming capabilities.

  • Keysight Dual 4x16 Armature Matrix for 34980A

    34932A - Keysight Technologies

    The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses

  • 16-Channel 250kSa/s USB Modular Multifunction Data Acquisition

    U2352A - Keysight Technologies

    The U2352A offers multifunction capabilities in a module. It can be used like a digital multimeter in polling mode. It can be transformed to be a simple scope using the continuous mode with simple triggering capabilities. No matter if it is used as a standalone module or when plugged into a U2781A USB modular instrument chassis, the synchronization and triggering capabilities allow great flexibility in making the desired measurements. The digital IO channels allows for closed loop control through connections to switches, relays and solenoids. The burst mode enables the U2352A to simulate simultaneous analog input acquisition.

  • PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays

    M9101A - Keysight Technologies

    The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.

  • Data Acquisition System

    DAQ - North Atlantic Industries

    Data Acquisition (DAQ) systems are used to collect information for the purpose of documenting or analyzing an electrical or physical phenomenon, for example: temperature or pressure. They serve as a focal point in tying a wide variety of sensors together that indicate temperature, flow, level or pressure. The sensors convert a physical occurrence into a measurable electrical signal, which can be factored into command and control decisions. These high-speed DAQ systems feature different analog and digital input and output modules that can be used with a wide range of signal types including 4-20 mA current, thermocouples, and RTDs.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • 16-bit, 100KHz, 16SE/8DIFF A/D Inputs; 4 14-bit, 30KHz D/A Outputs, 4 24V Digital I/O, All Isolated

    APCI-3120-16-4 - TEAM SOLUTIONS, INC.

    *Optical isolation 500 V*16 SE or 8 diff. inputs*Data transfer rate: 100 kHz*16-bit resolution*4 analog output channels*Data transfer rate:30 kHz*14-bit resolution*Output voltage: 0-10 V, ±10 V, (set through software)*Each output has its own ground line*Driver capacity: 5 mA/500 pF*Short-circuit protection: EMI filters*Data exchange through 16-bit I/O digital*4 digital inputs*and 4 digital outputs, 24 V , opto-isolated

  • 6 Digits Process Meter

    A6-PR - Chuan Sheng Electronics Co., Ltd.

    A6-PR 6 Digits Process Meter has been designed with high accuracy measurement, 6 digit display, flexible I/O functions and communication port for process measuring application.There are also build in 4x External Control Inputs, and can option 4x Relay outputs, 1x Analog output and 1x RS485 (Modbus RTU Mode) communication port with multi-functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.There was designed the zero tracking and stable tracking function in programming level.According to the application, user can set the function to get the suitable reading.

  • Pressure Transmitter

    PS2 - Chuan Sheng Electronics Co., Ltd.

    - Digital temperature compensation and nonlinear correction- High sensitivity, high precision, high stability- Full temperature compensation, good electrical performance and long-term stability- The plug and shell are integrally spin-stable, stable and waterproof, to avoid loosening the thread of ordinary plug- A variety of signal outputs, convert the pressure of the measured medium into 4~20mA,0~10VDC analog signals, RS485 digital signals- With RS485 communication interface, the monitoring system can easily read the measured value- The shell adopts laser welding, high reliability, long life, long-term stability and reliability

Get Help