Filter Results By:

Products

Applications

Manufacturers

4-wire

resistance measurement using an ohmmeter's two each, force and sense leads.

See Also: Resistance


Showing results: 136 - 150 of 224 items found.

  • Dual Channel Multi-Band FM Tracking/Data Receiver In Modular Style Housing

    LS-27-B - Lumistar Inc.

    The Lumistar LS-27-B Modular Dual Channel Tri-Band Tracking and Data Receiver is Lumistar’s third generation of modular high performance FM Receivers. This wideband designs supports one or two independent channels of PCM with data rates up to 20Mbps. The unit includes both an optional FM demodulated output for PCM data, and standard programmable AM/linear AGC outputs for auto-tracking receivers. The design offers 8 IF Bandwidths and 8 Video Filters per channel for each receiver.AC coupling with a low pass filter is employed to ensure a high quality data link with long strings of NRZ-L ones or zeroes. The unit provides a software selectable 10 MHz reference I/O port forlocking local oscillators to a high precision external source or to arrange multiple units in a master/slave arrangement. The receiver’s control and status is achieved via Ethernet, USB or auto-switched RS-232 (or “4-wire” RS-485 in place of 232). When utilizing the RS-422 interface, multi-drop configurations can be accommodated.

  • Dual MAX31865 PT-100 RTD to Digital Breakout

    SEN-30202-PT100 - Playing With Fusion Inc

    Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.

  • Electrical 5-in-1 Production Safety Analyzers

    Model 19032/19032-P - Chroma ATE Inc.

    Electrical Safety Test (EST) Analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.

  • Inputs Temperature Data Logger – Pt100

    HD32.7 - Delta OHM S.r.L.

    The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • MAX31855 J-Type Thermocouple Sensor Breakout

    SEN-30003-J - Playing With Fusion Inc

    Breakout board for the MAX31855J digital thermocouple interface ICs by Maxim. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws. The SEN-30003 is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance (many other level shifters reduce data rates to below 500 kHz).

  • Power Quality Analyzers

    HIOKI E.E. Corp

    3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class A Standards with Dynamic 1300V Range, Harmonic and Inter-harmonics Analysis Capabilities

  • Resistance Measuring Equipment

    Soken Electric Co. Ltd

    measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.

  • Resistive Touch Controllers

    Analog Devices Inc.

    Analog Devices offers a range of controller ICs for use with 4-wire resistive touch screens. These controllers can be used in human machine interface applications in consumer, automotive, and other products. Analog Devices’ controllers have 12 bits of resolution, SPI/I2C interface options, and low power consumption, making them ideal for use in handheld devices.

  • RS232 / RS485 / RS422 Isolators/ Isolated Converters

    CommFront Communications

    From 3-wire to 7-wire RS232 isolators, 2-wire RS485 to 4-wire RS422 / RS485 isolators, and USB isolators to USB / RS232 / RS485 / RS422 optically-isolated converters, CommFront has all the industrial-grade optical-isolation devices to protect your assets from the unexpected. If off-the-shelf product does not provide enough security for you, we can even tailor-make the devices, which are customizable right down to the nuts and bolts.

  • RTD Measurement for CompactPCI

    CPCI390 - AcQ Inducom

    The CPCI390 has a 3U form factor and features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm limit checking. Sensordata is available in °C, °F, K and Ohm. All inputs are optically isolated from the system.

  • RTD Measurement for PCI

    PCI390 - AcQ Inducom

    The PCI390 features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm-limit checking. Sensor-data is available in °C, °F, K and Ohms. All inputs are optically isolated from the system.

  • Serial to GPIB Controller

    Model 4895 - ICS Electronics

    ICS's Serial to GPIB Controller allows any computer with a serial port to control GPIB devices. Works with RS-232 and 2 or 4-wire RS-422/RS-485 signals. Use to add GPIB Capability to PLCs with serial ports.

  • SICRAM Module

    TP47 - Delta OHM S.r.L.

    4-wire Pt100 probes