  • PCI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.8 MS/s), 24 DIO PCI Multifunction I/O Device

    779109-01 - NI

    The PCI‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB I/O Module for Sound and Vibration

    JSV-4431-USB - Jumho Electric Corporation

    4-channel ICP analog voltage input 102.4KS/s maximumsample rate, simultaneous acquisition Analog-to-digital converter:delta-sigma, 24 bits Phase Accuracy < 0.05deg@10KHz Optional Input voltage range: ±10 V,±5V, ±1Vm ±100mV ; Signal conditioning: anti-aliasing filter Digital filter: user-defined low pass, high pass, band pass, band stop Dynamic range: 100 dB ICP current: 0-4 mA, optional 1-channel analog output voltage:±3.5 V; update rate: 96 kS/s Overload indication: software display

  • 3-Slot Data Acquisition Mainframe With GPIB And Three 20-Channel Multiplexer Modules

    DAQ973MB - Keysight Technologies

    The DAQ973MB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance

  • 4 Digit Temperature Meter (5 Channels)

    CM1-TX5 - Chuan Sheng Electronics Co., Ltd.

    RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel

  • DataBlaster PCI / PCIE JTAG Boundary-Scan Controller

    JT 37x7/PCI - JTAG Technologies Inc.

    High speed and performance JTAG Boundary-scan PCI PC plug-in controller for PCI bus slot or PCIe PC plug-in controller for PCI Express bus slot.The controllers are targeted at demanding manufacturing test applications, fast in-system flash memory programming and programmable logic configuration. The JT 37×7 is available in different operating levels (memory options) to suit your specific environment and application. Each unit is supplied with a four TAP port signal conditioning module the JT 2147 ‘QuadPOD‘

  • Toxic Gas Sensor

    Model 100 - Teledyne Gas & Flame Detection

    Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

  • Pressure Sensor Interface

    USB2251 - Validyne Engineering

    The USB2251 Pressure Sensor Interface provides real-world data acquisition for your PC via the USB port. 8 calibrated variable reluctance pressure sensor inputs are accepted by the USB2251. No external signal conditioning is required.The USB2251 includes a connector panel for sensor cables, calibration constants for each sensor , configuration and data acquisition software. The USB2251 produces a floating-point value for all readings, directly in engineering units.The USB2251 can record pressure readings up to 5000 samples per second. Combined with the fast response of the Validyne VR pressure sensors, the USB2251 is ideal for transient pressure studies. The USB2251 is compatible with the following Validyne variable reluctance pressure sensors: AP10, DP103, DP10, DP45, DP15 DP360, DP215, and DP363. Each sensor is calibrated with the USB2251 at the factory and is ready to make measurements.

  • Signal Conditioners

    General Purpose - Encore Electronics, Inc.

    Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.

  • Boundary-Scan Controller for PXI-Express 'Hybrid' Slots or Plug-In Controller for PXI-Express Peripheral Slot

    JT 37×7/PXIE - JTAG Technologies Inc.

    High speed and performance JTAG Boundary-scan controller for PXI-Express ‘hybrid’ slots or plug-in controller for PXI-Express peripheral slot.The controllers are targeted at demanding manufacturing test applications, fast in-system flash memory programming and programmable logic configuration. The JT 37×7 is available in different operating levels (memory options) to suit your specific environment and application. Each unit is supplied with a four TAP port signal conditioning module the JT 2147 ‘QuadPOD‘The JT 37×7 DataBlasters are a family of high speed and performance, up to 40 MHz TCK, boundary-scan controllers. Besides being available as bench-top unit with USB/E-net/FireWire interface, these controllers also come as 19″ rack-mountable instrument with the same three interafces and as plug-in cards in PXI(e)and PCI(e) formats.

  • Servo-Pneumatic Asphalt Testing System

    Atico Export

    All signal conditioning, as well as high-speed data acquisition and control functions are done by the unit and graphically interfaced through CATS, windows based software running on a standard PC. The system is capable of performing the full spectrum of HMA tests: dynamic complex modulus, flow number, flow time, indirect tension, beam flexural fatigue and resilient modulus. These tests are done with the appropriate testing modules. The different testing modules can be obtained after the initial system acquisition at the same discounted price. In addition, guarantees system upgrades in order to meet future standards .

  • PXI-6284, 32 AI (18-Bit, 625 kS/s), 48 DIO, PXI Hybrid, Multifunction I/O Module

    779122-01 - NI

    32 AI (18-Bit, 625 kS/s), 48 DIO, PXI Multifunction I/O Module—The PXI‑6284 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PXI-6224, 32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Hybrid, Multifunction I/O Module

    779114-01 - NI

    32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Multifunction I/O Module—The PXI‑6224 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PCI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO PCI Multifunction I/O Device

    779068-01 - NI

    32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO PCI Multifunction I/O Device - The PCI-6229 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PCI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device

    779418-01 - NI

    16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device - The PCI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PXI-6280, 16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Hybrid, Multifunction I/O Module

    779120-01 - NI

    16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Multifunction I/O Module—The PXI‑6280 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.