Filter Results By:

Products

Applications

Manufacturers

Signal Conditioning

The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.

See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners


Showing results: 466 - 480 of 486 items found.

  • sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module

    781028-01 - NI

    Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.

  • PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module

    781370-01 - NI

    204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module

    781369-01 - NI

    204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Portable JTAG Boundary-Scan Controller with USB (1.1 and 2.0 High Speed), Ethernet & Firewire Interfaces

    JT 37x7/TSI - JTAG Technologies Inc.

    High speed and performance portable JTAG Boundary-scan controller, containing three interfaces to the test system: USB (1.1 and 2.0 high speed), Ethernet and FirewireThe controllers are targeted at demanding manufacturing test applications, fast in-system flash memory programming and programmable logic configuration. The JT 37×7 is available in different operating levels (memory options) to suit your specific environment and application. Each unit is supplied with a four TAP port signal conditioning module the JT 2147 ‘QuadPOD‘The JT 37×7 DataBlasters are a family of high speed and performance, up to 40 MHz TCK, boundary-scan controllers. Besides being available as bench-top unit with USB/E-net/FireWire interface, these controllers also come as 19″ rack-mountable instrument with the same three interafces and as plug-in cards in PXI(e)and PCI(e) formats.

  • 2-Channel Front End

    BEQ II.1 - HEAD acoustics GmbH

    *Binaural, digital equalizer with 24 bit technology and USB interface.*The digital equalizer BEQ II.1 combines the characteristics of an equalizer, a two-channel front end and an A/D converter into one mobile and very versatile measurement tool.*Binaural, aurally-accurate recordings can be conducted easily with BEQ II. The AES/EBU interface allows a quick and easy expansion into a four-channel system, e.g. with the HMS III or HMS IV. Via the ADAT interface, up to four BEQ II units can be connected, allowing for eight-channel recordings.*Integrated signal conditioning allows common measurement sensors (Microphone, Line, ICP�) to be directly connected to the front end. In addition, separate pulse inputs are available e.g. for RPM data acquisition.*Thanks to the high-performance built-in battery - external DC power supply is also possible - and its low weight, BEQ II.1 is the ideal tool for either mobile or stationary operation.

  • Tactical Grade Inertial Measurement Unit (IMU)

    ADIS16490 iSensor - Analog Devices Inc.

    The ADIS16490 iSensor® device is a complete inertial system that includes a triaxial gyroscope and a triaxial accelerometer. Each inertial sensor in the ADIS16490 combines industry-leading iMEMS® technology with signal conditioning that optimizes dynamic performance. The factory calibration characterizes each sensor for sensitivity, bias, alignment, and linear acceleration (gyroscope bias). As a result, each sensor has its own dynamic compensation formulas that provide accurate sensor measurements. The ADIS16490 provides a simple, cost-effective method for integrating accurate, multiaxis inertial sensing into industrial systems, especially when compared with the complexity and investment associated with discrete designs. All necessary motion testing and calibration are part of the production process at the factory, greatly reducing system integration time. Tight orthogonal alignment simplifies inertial frame alignment in navigation systems. The SPI and register structure provide a simple interface for data collection and configuration control.

  • Long Gauge Length Axial Extensometers

    Model 3542L - Jinan Testing Equipment IE Corporation

    The dual flexure design makes the 3542L very rugged and insensitive to vibrations. These extensometers are designed for testing a wide range of materials including metals, plastics, composites and ceramics. Epsilon’s Model 3543 is recommended for applications requiring long gauge lengths and larger measuring ranges.The Model 3542L comes standard with Epsilon’s quick attach kit, making it easy to mount the extensometer on the test specimen. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The 3542L extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • High Temperature Diametral Extensometers (1000 C)

    Model 3580 - Jinan Testing Equipment IE Corporation

    This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Averaging Extensometers for ASTM D5656 Shear Tests

    Model 4013 - Jinan Testing Equipment IE Corporation

    The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Axial Extensometer

    Model 3542 - Jinan Testing Equipment IE Corporation

    These extensometers are designed for testing a wide range of materials, including metals, plastics, composites and ceramics. All will work in both tension and compression. The dual flexure design makes them very rugged and insensitive to vibrations, which permits higher frequency operation.They come standard with Epsilon’s quick attach kit, making it possible to mount the extensometer on the test specimen quickly and easily with one hand. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The Model 3542 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.For gauge lengths 100 mm (4 inches) or greater see Model 3542L.

  • 6000 Series Analog I/O Modules

    Pacific Instruments, Inc.

    Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.

  • High Temperature Furnace COD Gages (1200 C or 1600 C)

    Model 3548COD - Jinan Testing Equipment IE Corporation

    These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • Extensometers for Indirect Tensile Testing of Asphalt

    Model 3911 - Jinan Testing Equipment IE Corporation

    For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

Get Help