Filter Results By:

Products

Applications

Manufacturers

Calibration Standards

A qualified quantified source of known value.

See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References


Showing results: 376 - 390 of 408 items found.

  • Surface Resistance System Kit

    PRS-801RM - Prostat Corporation

    - Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

  • 800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards

    DL411 - Advance Plus Trading Co., Ltd.

    Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.

  • Moisture Meters

    PCE Instruments

    Moisture can be found in any material. Even materials considered to be dry have a minor amount of moisture. An imbalance of moisture, whether it be excessive moisture or too little moisture, can cause problems ranging from undesired mold and bacteria growth to cracks and defects. To avoid a moisture imbalance, it is essential to monitor moisture content with a moisture meter that returns accurate and reliable measuring results. A moisture meter can measure the moisture content of everything from the air (relative humidity) to construction and building materials (concrete, wood) to biomass and agricultural products (hay, straw, grain, corn, beans, pellets) to solid waste (pulp, slurry) and beyond. Many moisture meter devices can also measure temperature. The moisture measurement range of each moisture meter varies depending on the model. Some moisture meter products take moisture measurements, store the moisture measurement data to an internal memory or SD cad, and allow the stored moisture measurement data to be transferred to a computer for detailed analysis by means of an evaluation software. PCE Instruments' moisture meter products come factory calibrated. ISO calibration certificates are available optionally for purchase as accessories to most moisture meter models. An ISO calibration certificate may be important to your company in meeting specific quality standards.

  • Light and Energy Meter

    Model 659 - OAI

    UV Light and Energy Meter for use with all wafer steppers. For over 45 years, OAI is a world leader in UV Light and Energy Measurement Instrumentation used for reliable accurate calibrated control of the photolithography processes in the Semiconductor, MEMS, Wafer Packaging and Wafer Bumping Industries. The New Model 659 is an advanced UV exposure analyzer specifically designed for use with all wafer steppers including high intensity wafer steppers. This meter averages up to 400 exposure readings, has Ethernet and USB interface for downloading recorded measurements, and has intensity range of up to 7,500mW/cm2. Probes are available in wavelength of 365nm, 400nm, 420nm & 436nm. OAI has a complete certified calibration lab to maintain the performance, quality and reliability of our meters. The Model 659 meter is traceable to NIST standards.

  • Emissions Dynamometers

    MD-250-M - Mustang Dynamometer

    Mustang has developed a low-cost, simple to use, easy-to-install heavy duty chassis dynamometer that can be used to simulate real-world driving conditions in a safe, controlled environment and can also be used for “static” diesel smog testing for regulatory purposes. This model is used in Diesel Smog Programs in Nevada and Colorado when combined with an approved opacity meter. The MD-250-M is a compact dynamometer with industry proven design features including 10.7-inch rollers, heavy duty spherical pillow-block ball bearings, welded structural steel frame, 7.5 hp calibration motor, and an industry standard air-cooled, Eddy Current Power Absorption Unit (PAU) for road-load simulation. The MD-250-M is available in both right and left hand configurations to accommodate different facility designs.

  • Mass Flow Controller for Medium Flow

    HFM-201 / HFC-203 - Teledyne OEM Solutions

    The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 me​ters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.

  • M​​ass Flow Controller for Medium Flow

    HFM-205 / HFC-207 - Teledyne OEM Solutions

    The HFM-205/HFC-207, Teledyne Hastings' flexible,​ general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.

  • Low Pressure Drop Thermal Mass Flow Meter

    HFM-200 LFE - Teledyne OEM Solutions

    The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.

  • Single Space Electro-hydraulic Servo Universal Testing Machine

    WAW-F Series - Jinan Testing Equipment IE Corporation

    WAW-F series single space Servo-Hydraulic Testing System Computerized is suitable for testing tension, compression and other strengths of various metallic or nonmetallic materials with high strength. The ultra-large testing space & dual-action actuator with longer stroke enable it to test not only standard specimen, but also longer ones with long elongation every so often. Equipped with the electronics, computer &software packages, it is capable of controlling the test procedures by the predetermined programs. The Servo-Hydraulic Testing System Computerized can also display, record, process and print the test results. The test curves can be drawn automatically in real time. The Servo-Hydraulic Tester of Single Space is easy to operate and is versatile in the applications of metallurgy manufacturers such as steel mills & alloy, reinforced bar, aircraft industry, research institutes, laboratories, calibration institutes etc.

  • Durometer - Shore Hardness Tester

    Qualitest International Inc.

    Qualitest provides quality control departments and research laboratories with an extensive range of top quality Durometer and hardness Tester for accurate hardness determination on all natural and synthetic rubber products and soft elastic materials, plastics, acrylic glass, acetates, casting resin, polyester, thermoplastics, PVC, neoprenes, hardboards, wood, leather, fruits and much more. Our products provide the highest precision (normally 0.5% or better), quality and craftsmanship, durability, “yet require” almost no calibration in many years after the purchase. Our designs are engineered so that the Durometer stays precisely within the standard requirements. Qualitest Durometers are referred to as the “Swiss watches” among other products on the market. Investing in our line of Durometer is a guarantee of accuracy and assurance for many years of operation.

  • M​​ass Flow Controller for Medium Flow

    HFM-205 / HFC-207 - Teledyne Hastings Instruments

    The HFM-205/HFC-207, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.

  • Low Pressure Drop Thermal Mass Flow Meter

    HFM-200 LFE - Teledyne Hastings Instruments

    The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.

  • Mass Flow Controller for Medium Flow

    ​​HFM-201 / HFC-203 - Teledyne Hastings Instruments

    The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.

  • Load Pull

    Focus Microwaves

    All Focus tuners use extremely efficient calibration and tuning algorithms and control electronics based on LAN control (iTuner). This is a merger our proven tuner technology with state of the art control electronics to create the latest tuner generation. The on-board micro-processor and tuning firmware form a self-contained and fully calibrated test instrument. The micro-processor inside the tuner accepts ASCII format communication, via an industry standard TCP/IP interface, controls up to nine stepper motors (tuner axes) and executes interpolation and tuning functions for single probe (CCMT) tuners (one probe per frequency range). For tuners with more than one independent probe (MPT) covering the same frequency range to allow for harmonic tuning, external computing power is required, because of the exponentially growing number of combinations of tuner states (slug positions).

Get Help