Showing results: 1 - 15 of 17 items found.
-
HE-200H -
HORIBA, Ltd.
HE-200H connects conductivity sensor (FES-125F,126F) and measures conductivity and temperature in the sample water. It can be used not only for measurement of electrical conductivity in aqueous solution, but also for concentration adjustment and rinse monitoring of CIP, etc., as well as for concentration monitor of process.
-
HE-300C -
HORIBA, Ltd.
HE-300C connects conductivity sensor (ESH/FS Series) and measures conductivity and temperature in the sample water. It is suitable for monitoring pure water/boiler water drainage recovery control and inline measurement of pharmaceutical water conductivity according to USP<645> quality guidelines.
-
HE-200C -
HORIBA, Ltd.
HE-200 connects conductivity sensor (ESH/FS Series) and measures conductivity and temperature in the sample water. It is suitable for monitoring pure water/boiler water drainage recovery control and inline measurement of pharmaceutical water conductivity according to USP<645> quality guidelines.
-
MRC ltd.
Conductivity meter measures the amount of electric current or conductivity in solution.A conductivity meter measures the health status of the natural water body.It is very useful in the field of water.
-
HE-960CW -
HORIBA, Ltd.
HE-960CW connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. It is ideal for the conductivity control of the purified water, pasteurized water, and water for injection that are used in the production of pharmaceuticals.And we have developed a lineup of electric conductivity sensors that can be used in conjunction, from the conventional insertion type to the flow-through type with improved cleaning and sanitary properties.
-
PCE Instruments
There are both standard and a waterproof conductivity meter, as well as a conductivity meter available for flowing water or pure water (highly recommended for specific industries) as well as the ones with different conductivity measurement ranges. An important factor is that a conductivity meter normally measures electric conductivity in µS/cm, however it can also take measurements in mg/l (for direct reading of content in dissolved solid substances). The relation is established as follows: 2 µS/cm = 1ppm (parts per million) = 1 mg/l. Compensated temperature in the conductivity meter can be automatic or by hand.
-
HE-960HI -
HORIBA, Ltd.
HE-960HI is a wide-range type sanitary electric conductivity meter that can measure over a wide range from manufacturing water up to 500 mS/cm, and enables advanced concentration management through abundant outputs. It connects conductivity sensor (FES-220/310). Cleaning-in-Place (CIP) terminal management and a reduction in cleaning solutions is also achieved through accurate surface detection.And we have developed a lineup of electric conductivity sensors that can be used in conjunction, from the conventional insertion type to the flow-through type with improved cleaning and sanitary properties.
-
Sper Scientific
The amount of mineral and salt impurities in the water is called total dissolved solids (TDS). TDS shows how many units of impurities there are for one million units of water. One way to measure impurities in water is to measure the electric conductivity of water. Absolutely pure water is a poor conductor of electricity. Water shows significant conductivity when dissolved salts are present. Over most ranges, the amount of conductivity is directly proportional to the amount of salts dissolved in the water or Salinity.
-
NC-6800 -
NAPSON Corp.
*Non-contact measurement of resistivity, thickness and conductivity (P/N)*Number of cassette station can be changed by customers request*Eddy current method for resistivity, Electric capacitance method for wafer thickness*Temperature correction for silicon wafer function
-
CI2000-RQD -
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure.
-
FES-210L -
HORIBA, Ltd.
The FES-210L Series sanitary conductivity sensors are electric sensors that target sanitation issues by employing a flat structure that keeps dirt from adhering to the tip of the sensor, and they enable continuous, high accuracy measurement in liquids of various concentrations, from purified water to cleaning solutions.The FES-210L Series, which is used in conjunction with the conductivity converter HE-960HS, demonstrates the optimum high sanitary characteristics that are ideal for the concentration and CIP management employed at food (beverage) and cosmetics plants.
-
Elcometer Limited
Users can either place a sample on the meter’s flat sensor or immerse the meter’s sensor directly into the solution under test. The Elcometer 138 can be used for a broad range of applications, including: soluble salt concentrations, the electric conductivity (EC) of solutions used in agricultural operations and measuring rainwater pollution levels.
-
Nexera Organic Acid Analysis System -
Shimadzu Corp.
The Nexera Organic Acid Analysis System has been well-received in the fields of food and environment as a highly selective high-sensitivity system. It uses separation by ion exclusion chromatography and Shimadzu’s unique detection technique (pH-buffered electric conductivity detection). Recently, this system is being utilized by even more users in a wide variety of fields, and its usage in the fields of pharmaceuticals and life science is increasing.
-
PVE-80 -
NAPSON Corp.
*No damage measurement by non-contact Pulse-Voltage excitation method*Easy to measure & carry around, Removable stage plate*Easy operation and data processing by PC with Software*Measurement result can shown by 3 types of measurement unit (Sheet resistance[Ohm/Sq], Electric conductivity[S/cm], Electrical conduction[S])*Pulse-Voltage excitation method : Pat. No.5386394 Joint development with Chiba Univ.
-
LA-1 HC -
Walter G. Legge Company Inc.
LA-1 HC Floor Conductivity Tester Hand Crank is an easy-to-use meter developed for accurately testing the conductivity of floors and equipment. The LA- 1 must be used regularly to monitor proper conductivity with NFPA code # 99. Regular use of the LA-1 will establish and maintain procedures for the proper maintenance of conductive floors, eliminate fire hazards, and provide a static free environment. A hand crank AC type generator provides a rectified DC test potential. Additionally, there are no brushes to wear out. The LA-1 has an easy-to-read scale that is selectively expanded electronically to assure accurate readings over the entire range of the instrument and the scale has a length of 3.75. This is 42% longer than typical competitive testers. The LA-1 uses 500V DC to test the resistance (in ohms) between two points. (NFPA Code #99) The meter comes ready-to-use (tin foil must be applied to bottom of weights). Simply follow the instructions for use and instantly obtain an accurate measurement. Choose electric or hand powered model.