Filter Results By:
Products
Applications
Manufacturers
Rogowski
inventor and namesake of measurement principle.
See Also: Coil, Helmholtz Coils, Coil Turns, Current Sensors
-
product
Rogowski Coil
INTEGRATORS FOR ROGOWSKI COILS
*High accuracy Class 0.5 (IEC 61869-2)*Combined with LEM ART & ARU class 0.5 Rogowski coils, they offer a universal metering and monitoring solution easily integrated with a monitoring device.*DIN rail mounted.
-
product
Rogowski Coil
Rogowski Coils are mainly used to measure high current through the conductor. As opposed to conventional current transformers, Rogowski Coils are liner over wide range of current input. Rogowski Coils along with current meter are suitable for measurement of AC or DC current, up to a few thousand amperes. Ferrites India offers Flexible as well as hard Rogowski Coil which can accomodate wide conductor sizes.
-
product
Rogowski Coil
A Rogowski coil produces a voltage output based on the rate of change of the current input. The absence of magnetic core ensures low inductance and comes with no saturation, resulting with a fast response and no inserted losses.
-
product
Rogowski Coil
ARU Series
*Class accuracy 0.5 conductor centered according to IEC 61869-10*Better than 1% accuracy regardless of the primary conductor’s position*Rated insulation voltage 1kV CATIII
-
product
Rogowski Coil
ART Series
*Class accuracy 0.5 conductor centered according to IEC 61869-10*Better than 0.75% accuracy regardless of the primary conductor’s position*Rated insulation voltage 1kV CATIII
-
product
Rogowski AC Current Probe
RCP500
Shenzhen Micsig Instruments Co., Ltd.
Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup,
-
product
Rogowski Coil Current ProbesTOP
*Switching current waveform and pulse response characteristics of power devices*Current measurements of inverter system*AC current measurements (at large DC offset)*Impulse high current measurements*Bus Bar high current measurements
-
product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
product
Rogowski AC Current Probe, 23 MHz, 3000 A
N7040A
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
product
AC Current Probes
CWT
Power Electronic Measurments Ltd
The CWT Rogowski current probe is suitable for measuring AC currents ranging from 300 milliamps to hundreds of kA from below 0.1Hz to >30MHz.
-
product
4 Phase Flexible AC Current Probe
DRM 504/18
The new DRP 504/18 is a 4 Phase Flexible AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
product
3 Phase Flexible AC Current Probe
DRP 503/18
The new DRP 503/18 is a 3 Phase Flexible AC current Probe utilising the Rogowski principle, with 3 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
product
4 Phase MICRO~Flex AC Current Probe
DRM 504/4
The new DRM 504/4 is a 4 Phase MICRO~flex AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
product
Wide Range Flexible Current Probe
EFX6000
The EFX6000 is a flexible AC current clamp utilizing the Rogowski principle. It can be used to measure currents from 1 amp to 6000 Amps in 2 auto-ranges, over a wide frequency range to 10kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, around large conductors and where access to confined or tight spaces is a problem. It requires no batteries or external power supply.
-
product
Power Quality Analyser
PM7000
It offers virtually everything needed to monitor and record power for surveys and audits. It includes 4 voltage input channels capable for measuring 0 to 600 Vac and 4 current input channels for use with voltage output current clamps, or Rogowski Coil sensors supplied. Twelve pre-stored connection configurations are set for 3 phase, 2 phase and single phase measurements. Users can also configure their own set-up and math calculation requirements and save them to non-volatile memory.
-
product
High Performance Polyphase Energy Metering AFE w/ Power Quality Analysis
ADE9000
The ADE9000 is a highly accurate, fully integrated energy-metering device. Interfacing with both current transformer (CT) and Rogowski coil sensors, the ADE9000 enables users to develop a three-phase metrology platform, which achieves high performance for Class 1 through Class 0.2 meters. Power quality features enable advanced meter designs with fast rms measurements and power quality level monitoring for EN50160 compliance. The ADE9000 integrates seven high performances ADC’s, a flexible DSP core. An integrated high-end reference ensures low drift over temperature with a combined drift of less than ±25 ppm/°C max for the whole channel including PGA and ADC.