Showing results: 1 - 15 of 17 items found.
-
INTEGRATORS FOR ROGOWSKI COILS -
LEM
*High accuracy Class 0.5 (IEC 61869-2)*Combined with LEM ART & ARU class 0.5 Rogowski coils, they offer a universal metering and monitoring solution easily integrated with a monitoring device.*DIN rail mounted.
-
Ferrites India
Rogowski Coils are mainly used to measure high current through the conductor. As opposed to conventional current transformers, Rogowski Coils are liner over wide range of current input. Rogowski Coils along with current meter are suitable for measurement of AC or DC current, up to a few thousand amperes. Ferrites India offers Flexible as well as hard Rogowski Coil which can accomodate wide conductor sizes.
-
LEM
A Rogowski coil produces a voltage output based on the rate of change of the current input. The absence of magnetic core ensures low inductance and comes with no saturation, resulting with a fast response and no inserted losses.
-
ART Series -
LEM
*Class accuracy 0.5 conductor centered according to IEC 61869-10*Better than 0.75% accuracy regardless of the primary conductor’s position*Rated insulation voltage 1kV CATIII
-
ARU Series -
LEM
*Class accuracy 0.5 conductor centered according to IEC 61869-10*Better than 1% accuracy regardless of the primary conductor’s position*Rated insulation voltage 1kV CATIII
-
RCP500 -
Shenzhen Micsig Instruments Co., Ltd.
Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup,
-
IWATSU Electronic Co., Ltd.
*Switching current waveform and pulse response characteristics of power devices*Current measurements of inverter system*AC current measurements (at large DC offset)*Impulse high current measurements*Bus Bar high current measurements
-
N7042A -
Keysight Technologies
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
N7041A -
Keysight Technologies
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
N7040A -
Keysight Technologies
The Keysight N7040A Rogowski coil current probe is designed for measuring AC currents up to 3,000 A with the bandwidth ranging from 3 Hz to 23 MHz. The probe is easy to use because it has a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult to reach parts and confined spaces of a circuit under test. It can also measure large AC current without increase in transducer size.
-
CWT -
Power Electronic Measurments Ltd
The CWT Rogowski current probe is suitable for measuring AC currents ranging from 300 milliamps to hundreds of kA from below 0.1Hz to >30MHz.
-
DRP 503/18 -
GMC-I-PROSyS
The new DRP 503/18 is a 3 Phase Flexible AC current Probe utilising the Rogowski principle, with 3 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
DRM 504/18 -
GMC-I-PROSyS
The new DRP 504/18 is a 4 Phase Flexible AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
DRM 504/4 -
GMC-I-PROSyS
The new DRM 504/4 is a 4 Phase MICRO~flex AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
EFX6000 -
Summit Technology, Inc.
The EFX6000 is a flexible AC current clamp utilizing the Rogowski principle. It can be used to measure currents from 1 amp to 6000 Amps in 2 auto-ranges, over a wide frequency range to 10kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, around large conductors and where access to confined or tight spaces is a problem. It requires no batteries or external power supply.