Filter Results By:

Products

Applications

Manufacturers

Impedance Analyzers

characterize impedance.

See Also: Frequency Response Analyzers, Frequency Analyzers, Network Analyzers, Impedance Testers


Showing results: 76 - 90 of 152 items found.

  • 1mm Verification Kit

    85059V - Keysight Technologies

    The Keysight 85059V is a 1.0 mm verification kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. This includes a set of standards with known characteristics, traceable to primary standards in the Keysight Technologies calibration lab. This verification kit is used to verify the measurement calibration and also to verify that the PNA/PNA-X based millimeter-wave system is operating within its specifications. The 85059V with 85059B 1 mm calibration kit are replacements for the 85059A 1 mm calibration/verification kit.

  • Electrochemical Interface

    Maccor Series 4000, Model 4200, and Model 4300 Automated Test Systems - Maccor, Inc.

    The Maccor Series 4000, Model 4200, and Model 4300 Automated Test Systems can be configured with an M option. This option adds a Multiplexer to the test system which allows the channels to be connected to a Princeton Applied Research PARSTAT 4000 or Solartron Analytical 1260/87 impedance analyzer. With the impedance analyzer connected to the test system via the multiplexer the user can then program impedance tests in the Maccor test procedure which when reached will cause the test system to automatically disconnect the Maccor test channel from the device and connect the impedance analyzer to the device. When the impedance test is completed the test system will then automatically disconnect the impedance analyzer from the device and connect the Maccor test channel back to the device and continue with the programmed test procedure. For the Series 4000 Automated Test System, multiple multiplexers and impedance analyzers may be connected to a single test system. Contact the Maccor sales department with any questions concerning this option and for information concerning other supported models of impedance analyzers.

  • Short Termination, 4-Terminal Pair

    42091A - Keysight Technologies

    Use for performance tests of the 4-terminal pair LCR meters and impedance analyzers.

  • Ultra Low Noise Preamp

    J2180A - PICOTEST Corp.

    The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.

  • Materials Test Systems

    Ametek Scientific Instruments

    An impedance analyzer is a device that uses a programmable AC voltage / current source, together with voltage and current measurement circuits, to characterize sample impedance over a wide range of frequency. An example of this being the world famous Solartron Analytical 1260A Impedance Analyzer that provides EIS impedance characterization over more than 12 decades of frequency from uHz to tens of MHz. Impedance Analysis characterization is a key technology that enables new materials development for semiconductors, smart-materials, ferroelectrics, piezo-electrics, solid oxide, solid electrolytes, ceramics, polymers, OLED and many more materials.

  • Noise Receiver Modules And Noise Switching Modules

    MT7553 Series - Maury Microwave Corporation

    Noise Parameters are the non-50Ω extensions of Noise Figure, and are an important modeling and model validation tool to understand how a device-undertest’s performance changes as a function of source impedance. Noise Parameter measurements are typically performedusing a Vector Network Analyzer (VNA) to measure the S-Parameters of the DUT, and a Noise Analyzer (either Noise Figure Analyzer NFA or Spectrum Analyzer SA) to measure the noise power of the DUT. Noise parameters are calculated from a combination of knownsource impedances, S-parameters and noise powers.

  • Component Parameter Testers

    Changzhou Tonghui Electronic Co., Ltd.

    Tonghui Component Parameter Testers - impedance analyzers, LCR meters, capacitance meters, inductance meters, etc.

  • EIS Interface (Electrochemical Impedance Spectroscopy)

    BATT470m - Newtons4th Ltd

    The BATT470m electrochemical impedance analysis interface (EIS) provides an easy to use battery/cell impedance test platform for the electrochemical industry. Utilizing the highly accurate PSM3750 frequency response analyzer from N4L, the BATT470 provides impedance measurement of batteries/cells up to 100V DC. With a frequency range of 100mHz to 1MHz, the BATT470m covers a wide range of applications. Our software package - PSMComm2, featuring “EIS” mode, displays the in-phase and quadrature impedance of the cell in Nyquist form as well as overall impedance (Z), in bode form.

  • Vector Network Analyzer

    MVNA-8-350 - AB Millimetre

    MVNA-8-350 is a vector network analyzer (VNA), an instrument which measures the complex, or vector, impedance (a real and an imaginary part of the impedance or an amplitude and a phase of the microwaves) in the millimeter and sub-millimeter frequency domain. It covers the frequency range from 8 GHz up to 1 THz.

  • Liquid Test Fixture

    16452A - Keysight Technologies

    The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.

  • Impedance Analysis

    S96041B - Keysight Technologies

    Make impedance analysis measurements of Surface Mount Device (SMD) components on the E5080B vector network analyzer with 16198A-010 10 GHz SMD test fixture.

  • DC Bias Injector

    J2130A - PICOTEST Corp.

    When using the network analyzer to measure impedance, such as the capacitance and ESR or a capacitor, or the DCR of an inductor, etc., it is often necessary to provide a voltage bias to the device being tested. This is true of semiconductor junction capacitances, varactors, and some ceramic capacitors (especially X5R). In these cases the impedance is a function of the DC bias on the device. The Picotest DC bias injector (J2130A) is used for this purpose during impedance measurements.

  • Addon Cards

    ZAHNER-Elektrik

    Fit the IM6/Zennium electrochemical workstation to your application. Control external potentiostats, capture additional physical properties or enhance your system to a true parallel impedance analyzer.

  • Open Termination, 4-Terminal Pair

    42090A - Keysight Technologies

    The 42090A is an open termination and is primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using this standard.

  • LCR Meters & Impedance Measurement Products

    Keysight Technologies

    Hewlett Packard, Agilent and Keysight have contributed innovations and product excellence in impedance analysis for over half a century. Whether your application is in R&D, production, quality assurance, or incoming inspection, we take pride in contributing to your success. We strive to deliver complete solutions to meet your needs, from impedance analyzers to a wide variety of test accessories. Achieve success with Keysight’s impedance measurement solutions.

Get Help