AccuMAX™ Series -
Spectronics Corp
Single detector with dual sensors measures both ultraviolet and visible light. Complies with ASTM specifications for MPI and FPI. Specially engineered for NDT applications. The AccuMAX XRP-3000 radiometer/photometer kit uses a dualwavelength UV-A/VIS sensor detector to measure both ultraviolet and visible light. Featuring automatic zeroing, integration and signal hold, the unit provides accurate readouts for UV, visible irradiance or radiance.
-
IRDL708 Series -
Amperis sl
The IRDL708 thermal imaging cameras are the new developed uncooled detector cameras, which have high resolution of 640x480 pixels, multi-rotary touch screen, normal and infrared image fusion, high brightness LED light, recording in H.264 format or normal format, images in JPEG format, light and sound alarm, voice and text annotations, network interface, built-in laser pointer, etc.
-
CoolOne -
HORIBA, Ltd.
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMT’s are durable, long-lived, and economical.
-
HU-200TB-EH -
HORIBA, Ltd.
HU-200TB-EH is a laser-type turbidity meter that can measure turbidity of membrane filtered water, etc. with a resolution of 0.0001 degrees. A high-sensitivity turbidty meter with a minimum resolution of 0.0001 degrees at a measurement range of 0.0000 to 2.0000 degrees, which uses a long-lasting semiconductor laser as the light source and employs a transmission 90-degree scattering light method.This is best suited for sensitive measurement of turbidity on surface water.
-
Shimadzu Corp.
MALDI is the abbreviation for "Matrix Assisted Laser Desorption/Ionization." The sample for MALDI is uniformly mixed in a large quantity of matrix. The matrix absorbs the ultraviolet light (nitrogen laser light, wavelength 337 nm) and converts it to heat energy. A small part of the matrix (down to 100 nm from the top outer surface of the Analyte in the diagram) heats rapidly (in several nano seconds) and is vaporized, together with the sample.
-
28056 -
Parallax Inc.
The Lightware SF000/B is an ultra-small and light open-frame LIDAR laser rangefinder designed for size and weight constraint applications. Using a time-of-flight system to make very fast, accurate distance and speed measurements. Accuracy is not affected by the color or texture of the surface, nor the angle of incidence of the laser beam. The SF000 is virtually immune to background light, wind and noise, making it an ideal sensor to detect unexpected obstacles.
-
mks Ophir
Photodiode sensors have a high degree of linearity over a large range of light power levels: from fractions of a nanowatt to about 2 mW. Above that light level, corresponding to a current of about 1 mA, the sensor saturates and reads erroneously low. Therefore, most Ophir PD sensors have a built-in and removable attenuator allows measurement of up to 3 W without saturation.
-
McPherson, Inc.
Reflective condensing system and focusing accessory for coupling light sources to monochromators. It uses two mirrors to focus to the entrance slit. The reflective system eliminates chromatic aberration, provides maximum spectral range, and does not require refocusing. Accessories like light choppers and filter wheels can also fit inside next to the slit. Versions with rotatable mirror available for up to four source direction.
-
Applied Scientific Instrumentation
ASI Modular Microscope components consist of tube lenses along with adapters and accessories that either are primarily used in the collimated light space or adapters that are to be used on the image side. Collimated light adapters use the 38mm diameter C60-RING system to connect components. Focus-side adapters attached to lens tubes with either a 30mm diameter coupling to the I.D. of the C60-TUBE, or with a 50mm coupling on the O.D. of the lens tube.
-
pE-100 -
CoolLED Ltd.
The pE-100 series is a mercury-free family of compact and simple to use LED illumination systems which can be configured to deliver light directly to a microscope, or via a liquid light guide or multimode fiber. Systems can be specified at any one of 20 different LED wavelengths. Operation is by a remote manual control pod with instant on/off and intensity control from 0-100%. Remote control is available via a TTL trigger.
-
72-6635 -
Tenma
*Large LCD Display, easy to read*Characteristic of "A" frequency weighting network are designer to meet IEC 651 type 2*Fast time weighting characteristic mode*Build in adj. VR is available for easy calibration*Condenser microphone for high accuracy & long-term stability*Hold function to freeze the display value*Warning indicator for over and under range*LCD display for low power consumption & clear read-out even in bright ambient light condition*Durable, long-lasting components, including a strong, light weight ABS plastic case*Small and light weight design allow one hand operation*Low battery indicator*High quality with economical cost
-
LMT Lichtmesstechnik GmbH
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
Yamashita Denso Corp.
It is the optimum light source for the evaluation of requiring high degree of parallelism close to sunlight. Irradiation area and parallelism are produced according to your request.
-
UVR Series -
TOPCON TechnoHouse Corp.
UVR series is suitable to manage lamp of ultraviolet curing equipment, Also suitable to measure intensity of ultraviolet ray for sun light and lamp.
-
Ocean Insight
Ocean Insight optical fiber assemblies, probes and accessories collect and direct light in spectrometer setups. Readily available in our online shop.