Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 154 items found.

  • Electrostatic Discharge

    Advanced Energy

    Our electrostatic discharge (ESD) measurement and control solutions include charge plate monitors, sensors, resistivity meters, and voltmeters. Reliably monitor, measure, locate, and test for static electricity.

  • Stationary Meter Test Systems AC

    ZERA GmbH

    Today Meter Test Technology is much more than only testing accuracy and functionality of a conventional electricity meters. With implementation of SmartMeters a complex test and data management system is required. – It’s a good thing to have experts by your side.

  • Accessories

    EDMI Ltd.

    EDMI offers accessories that allows communication with electricity meters.

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.

  • Three-phase Electricity Meters

    Applied Meters, a.s.

    Three-phase static electricity meters AMT B1x-S(D)xxTE are determined for single-rate or double-rate active energy measurement in direct and indirect connection, displaying results on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.

  • Portable Single-Phase Energy Standard

    PEWM-3C-1 - EMSYST Ltd

    The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.

  • Electricity Meter Test Equipment

    Applied Meters, a.s.

    The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase

  • Automatic Meter Reading Unit

    Signals & Systems India Private Limited

    SANDS make of AMR Modem SAM-1101 is a smart electricity meter reading device that can be connected to any make of electronic energy meter by means of optical/ RS232 port, which is compliant to DLMS – IEC 62056-21 standard. The electricity meters measuring energy consumption can be located in either consumer premises or in distribution transformers. The modem draws its power from the meter terminal block and connects to the communication port of the meter. Thus this add-on energy meter reading system is non-intrusive and can be retrofitted easily to any meter. The Electricity Meter Reading device uses GSM/GPRS communication technology and has built-in intelligence to talk to the DLMS meter. AMR system is compatible with 4G network to push the power consumption-billing data, load survey data, and event data to a cloud-based server, with fallback options to 3G & 2G.

  • CT Tester, Meter Tester, Circuit Analyzer

    GOLD MINER IV - EMSYST Ltd

    Gold Miner is the first device of its type to test the electricity meter using exact, simultaneous measurements made on all primary and all secondary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true accuracy resulting from the CTs + Meter combination for your entire measurement circuit.

  • Electricity Meter Test Equipment

    ELMA - Applied Precision Ltd.

    The Electricity Meter Test Equipment ELMA due to modular concept enables to tailor specifications to specific laboratory demand. The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories.

  • Portable Three-Phase Energy Standard

    PEWM-3C - EMSYST Ltd

    The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).

  • Single-phase Electricity Meters

    Applied Meters, a.s.

    Single-phase static electricity meters AMS B1x-SAx are determined for direct and indirect measurement of active energy displaying value on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.

  • Portable Electricity Meter Testers

    EE-120A-3S - EMSYST Ltd

    The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.

  • METES - Meter Test Systems

    KoCoS Messtechnik AG

    Dramatic advances in the field of measurement technology and the use of state-of-the-art micro-electronics have led to the development of a new generation of electricity meters which are far more accurate than their predecessors of just a few years ago. As well as measuring the exact amount of energy used, a high level of integration enables electronic meters to perform a number of additional functions. As a result, these meters are also more sensitive to network irregularities. This means that regular testing is the only way to ensure that a meter functions correctly, both during final factory tests and during the entire life span of a meter.

  • Portable Electricity Meter Testers

    EE-120A-1S - EMSYST Ltd

    The EE-120A-1S unit consists of a single-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types single-phase electricity meters using the voltage of the site. The meter error can be measured for active, reactive or apparent energy, in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the site – with direct measurement or with optional current clamps.

Get Help