Showing results: 31 - 45 of 276 items found.
-
-
Extech PQ34-12 -
Extech Instruments Corporation
The Extech PQ34-12 is a set of 1200 Amp Current Clamp Probes. For use with the PQ3450 and PQ3470 analyzers. Featuring a 50 mm (2 in) jaw size, this product comes with three current clamp probes and a year warranty.
-
Extech PQ34-2 -
Extech Instruments Corporation
The Extech PQ34-2 is a set of 200 Amp Current Clamp Probes. Use with the PQ3450 and PQ3470 analyzers. Featuring a 19 mm (0.8 in) jaw size, this product comes with three current clamp probes and a year warranty.
-
Monitran Ltd.
Proximity sensors work on the eddy current principle. A proximity system consists of an eddy current probe, extension cable and driver. A high-frequency RF signal is generated by the driver, sent through the extension and probe cables and radiated from the probe tip. The tip consists of a precision wound copper coil inside a chemical and temperature resistant PEEK case.
-
MP-50 -
FRANKONIA GmbH
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Extech 382097 -
Extech Instruments Corporation
Extech's 382097 is a set of 100A Current Clamp Probes for Models 382095 and 382096 Power Analyzers. This clamp probe set features three probes with a 30 mm (1.2 in) clamp jaw. The 382097 comes with a two year warranty.
-
FUSE PEEKER -
Automotive Diagnostics and Publishing
Automotive Fuse Peeker Current Probe for Testing Injectors, Coils, Solenoids and most components. The FUSE PEEKER Automotive Fuse Current Probe works with your own scope, the Auto Scope 1 or any other type of oscilloscope. It uses magnetic sensor technology, which is accurate and safe for your tool. It can detect small amounts of current as small as 5 milli-amps.
-
RCT1A and RCT5A -
Powertek LLC
These probes have great bandwidth ensuring accurate measurement even with harmonically distorted wave shapes. For all RCT1A/RCT models, a NIST, NAVLAP, NPL (UKAS) factory traceable calibration certificate and certificate of conformance is supplied. UL/CSA approved materials are used throughout. Three phase and single phase flexible AC current sensors (rope sensors) are available for fast installation in confined spaces, eliminating the need for Electrical Supply Shutdown. Available outputs are 1A @ 2.5VA and 5A @ 0.5VA, this means long cable lengths from current sensor to signal conditioner allow these low VA ratings to be used, even when feeder cable to energy meter distances are large (up to 98 feet / 30 meters)
-
RCP500 -
Shenzhen Micsig Instruments Co., Ltd.
Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup,
-
CTA -
Powertek LLC
The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.
-
Extech PQ3120 -
Extech Instruments Corporation
The Extech PQ3120 is a set of 1000 Amp clamp probes (set of 3) for the PQ3350 analyzer. These clamp probes have a 56 mm (2.2 in) jaw size.
-
Extech PQ3110 -
Extech Instruments Corporation
The Extech PQ3110 is a Clamp Probe kit for use with PQ3350 power quality analyzer. Comes with three clamps with a 30 mm (1.2 in) clamp jaw.
-
697 -
Electronic Specialties Inc.
Use this instrument to test starting and charging systems. It can even be used to test relative compression when used with your lab scope or graphing meter. Unit is designed for use with digital multimeters, lab scopes or graphing meters.
-
698 -
Electronic Specialties Inc.
Unit is designed for use with digital multimeters,lab scopes or graphing meters. With 1000 Amp capabiltiy, this instrument can be used to test starting and charging systems. It can even be used to test relative compression when used with your lab scope or graphing meter.
-
695 -
Electronic Specialties Inc.
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.