  • Medium-size Reverberation Chamber

    E-Series - Emite Ingeniería SL. Ed

    The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.

  • VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM

    HFDF - National RF, Inc

    National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.

  • PLD Systems

    Pulsed Laser Deposition - Neocera, Inc.

    Is a versatile thin film deposition technique. A pulsed laser (~20 ns pulse width) rapidly evaporates a target material forming a thin film that retains target composition. This unique ability of stoichiometeric transfer of target composition into the film was realized first by the research team led by Dr. Venkatesan at Bell Communications Research, NJ, USA, nearly 30 years ago while depositing high temperature superconducting (YBa2Cu3O7) thin films. Since then, PLD has become the preferred deposition technique where ever thin films of complex material compositions are considered. Another unique feature of PLD is its ability for rapid prototyping of materials. The energy source (pulsed laser) being outside the deposition chamber, facilitates a large dynamic range of operating pressures (10-10 Torr to 500 Torr) during material synthesis. By controlling the deposition pressure and substrate temperature and using relatively small target sizes, a variety of atomically controlled nano-structures and interfaces can be prepared with unique functionalities.

  • LANDTEK Digital Muscle Dynamometer Muscle Strength Tester FM-204M50KG

    FM-204M50KG - Guangzhou Landtek Instruments Co. Ltd.

    LANDTEK Digital Muscle Dynamometer Muscle Strength Tester FM-204M50KGApplications:Making job task analysis and ergonomic analysis simple and accurate, it is ideal for workplace design, strength assessment and ergonomic research.Details:Force Rang:±50kgf,±490N,±110LbfResolution:0.01kgf,0.1N,0.1LbfAccuracy:±0.5%FS ± 1DigitUnit:kgf, gf, N, LbfMeasurement State:Peak Value Measurement, Real Time MeasurementDisplay:2 Reversed 4 Digit LCDPower Off:10 Minutes Auto Power Off, Manual Power OffBacklight:BacklightSafe Load:150%FS (Buzzer Alarm Over 110%FS)Power Supply:2x1.5 AA(UM-3) Battery or 5VDC Power SupplyOperating:0°C~40°CConditions:< 80%Surrounding:No Vibration Source or Corrosive Medium AroundWeight:705 gSize:host machine:170mm*72mm*35mmhandspike:315mm*Φ30mm Instrument stents:155mm*95mm*35mmAccessories:Standard Accessories:ManualCarrying CaseInstrument stents4 M3*18 screwsE-1005Optional Accessories:External USB power supply cableE-1004For quotation please feel free to contact Lisa Li. Thank you.

  • 3D Guidance®

    Northern Digital Inc.

    The 3D Guidance® electromagnetic tracking solution delivers exceptional performance and value for OEM image-guided interventional and therapy systems and medical trainers that require real-time navigation tracking capabilities. The 3D Guidance solution tracks 6DOF sensors that can be embedded into OEM instruments such as ultrasound probes, rigid and flexible scopes, and laparoscopic tools. Continuous in-vivo tracking is maintained through difficult anatomy, even when sensors are out of sight. Low latency and fast update rates ensure the most subtle tool movements are instantly tracked and visualized within the OEM host interface. The 3D Guidance solution is available in the driveBAY™ and trakSTAR™ configurations, as based on the Electronics Unit. The trakSTAR is a standalone desktop unit that connects to a direct power source. The smaller driveBAY fits inside the drive bay of a computer, OEM imaging cart, or medical trainer/simulator, using the host’s power supply. Both share the same tracking accuracy and reliability. The ready-to-use configuration facilitates cost-effective integration and speeds time to market.

  • Precision Capacitance Meter

    TH2638C - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638 - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638B - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638A - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Thermitest

    THW-L2 - Thermtest Instruments

    Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.

  • VME

    Data Patterns Pvt. Ltd.

    One of the world's leading architectures for high reliability electronics applications is the VME platform.The VME standard is managed by the VME bus International Trade Association, VITA.Embedded computing's most successful bus standard, VME bus, shows no signs of slowing down as it maintains it's position as the industry's de facto standard into the 21st century. The foundation of VME's longevity, namely it's steady rate of technological evolution combined with a commitment to backward compatibility with legacy hardware and software, has been the linchpin of it's popularity for nearly twenty-five years. Today, innovative enhancements to the standard, through the VME Standards Organisation (VSO), continue to improve VME bus' speed, performance and reliability, strengthening it's position as the ideal solution for today's increasingly stringent commercial, industrial and military system requirements (Source: VITA).Data Patterns has implemented a number of standard VME boards, driven by Customer needs for Processor and I/O requirements in this platform. Today, standard modules are available covering the needs of:

  • Radiator Flow Test Machine

    8601 - Hydraulic Technology, Inc.

    The Radiator Flow Test Machine P/N 8601 meets all requirements of military specification MIL-F-45955A (AL). It is completely self contained and requires only connection to a source of shop electrical power to place in operation. A power cable complete with three prong grounding plug is permanently attached to the machine for this purpose. The unit consists of a water storage tank, a pumping system, a flow measuring system, a support and workstation, and the required hose adapters for connection to different size radiators. The complete unit is mounted on swiveling casters. The flow rate is infinitely adjustable from 0 to 120 gallons per minute by means of a panel mounted control valve. The machine is constructed from heavy 10 gauge steel, is double welded and is coated externally and internally with a water-resistant epoxy coating. Flow measurement is accomplished by a digital panel meter with a calibrated accuracy of plus or minus 3 percent of scale between 5 and 120 gallons per minute. Higher flows available on request.

  • Function Generators

    Shanghai MCP Corp

    Respective dual channels function/arbitrary waveform generator. Sine wave output up to 160MHz, full-band resolution of 1μHz. Pulse waveform up to 50MHz (or 40MHz), adjustable time of rising, falling and duty ratio. Sampling rate of 500MSa/s and vertical resolution of 16bit. 6-bit high-precision frequency meter compatible with TTL level signal. Arbitrary wave storage of 8~32M points, 7GB non-volatile waveform storage. Multi modulation function::AM,FM,PM, ASK,FSK,PSK, BPSK, QPSK,OSK,PWM, QAM, SUM . 16bit digital arbitrary wave (TTL level) DARB. 16th Harmonic Generation Function. Protocol output: I2C, SPI, UART (TTL level). 8 Inch high-resolution TFT color LCD,WVGA(800×480). Standard interface: USB Host, USB Device, LAN, 10MHz clock source input/output. Frequency sweep and burst output. Easy-to-use multi-functional knob and numeric keypad

  • Multi-Channel (Up to Four) MIL-STF-1760 Interface Board for Conduction Cooled PCI Mezzanine Card Compatible Computers

    EXC-1553ccPMC/Px(S)-1760 - Excalibur Systems, Inc.

    The EXC-1553ccPMC/Px(S)-1760 is a multi-channel (up to four) MIL-STD-1760 interface board for conduction cooled PCI Mezzanine Card compatible computers. In addition, Checksum, SRQ bit and Header Words are supported on each channel. Multi Function:Each channel operates simultaneously as a Bus controller and/or multiple (up to 32) Remote Terminals, or as a Triggerable Bus Monitor. In addition, error injection (BC and RT modes), error detection (all modes) and cableless internal loopback are supported on each channel. Single Function:Each channel operates either as a Bus Controller, Remote Terminal, or Bus Monitor.Each dual redundant 1760 channel can operate simultaneously as a Bus Controller and up to 32 Remote Terminals and as a Triggerable Monitor. In addition, error injection (BC and RT modes), error detection (all modes) and cableless internal loopback are supported on each channel. The EXC-1553ccPMC/Px(S)-1760 is supplied with C drivers, including source code, and Merlin+ Windows software.

  • Walk-In Solar Spectrum Test Chamber

    ACMAS Technologies Pvt. Ltd.

    WEIBER walk in Solar Spectrum Test Chambers are one of solutions to be utilized in large scale PV testing program. We offer customized as well as standard multidimensional test program for PV modules in reasonable prices. This system delivers the weathering stress representative of long term outdoor exposure.Our flexible system can be designed according to our test requirements, to suit environmental test conditions like volume, temperature, humidity solar radiation intensity and other measuring instruments. It is also called Walk in Solar Radiation Test Chamber.WEIBER solar test system are recognized for superior solar simulation environmental Testing, evaluating outdoor use product reliability, quality & safety. This technology allows for very high concentrations of UV energy without excessive heating of test samples. Custom mounting and cooling can be added depending upon specific material exposure requirements. MHGs (metal halide global lamps) are used as radiation source. Solar spectrum chamber also known as Walk in Solar Simulation Test Chamber