  • General Purpose

    Columbia Research Laboratories

    This group of accelerometers is made up of the 3000 and 5000 Series. The 3000 Series are standard size units, including many with all welded construction, that are hermetically sealed for use in dirty and humid environments. The 5000 Series are smaller and lighter in weight than standard units. Characteristics are almost identical except that with miniature units higher natural frequencies and shock levels can be obtained due to their inherently reduced mass. Sensitivities, however are somewhat lower. High Temperature models are available that operate to +500°F. For best performance use with the Columbia Model 4601 Charge Amplifier or Model 5810 Inline Charge Converter.

  • Humidity Chambers

    FW Series - Bemco Inc.

    The Bemco FW Series of mechanically cooled Glass Door Humidity Chambers have a a temperature range of -28 C to +177 C (-20 F to 350 F) or -73 C to +177 C (-100 F to 350 F) and a humidity range of up to 5% RH to 95% RH.. These chambers feature direct dry air injection and direct humidity sensors. They operate without dewpoint limit from 5% RH to 95% RH over the range of 30 C to 85 C and even allow operation at 20% RH at 5 C and 50% RH at -14 C!

  • Inclination Sensors

    WIKA Alexander Wiegand SE & Co. KG

    WIKA offers various different designs of inclination sensors. Inside the inclination sensors is a dielectric fluid, which - like a spirit level - aligns horizontally by gravity, without gravitational acceleration errors. The measurements are independent of gravitational fluctuations and therefore reproducible at every location. By detecting the differential capacitance, the inclination angle is calculated. With this technology, measurement is possible up to 360°. Accuracies of <0.1 % can be achieved with this. They are also available for redundant and multi-axis applications and with flameproof enclosures. WIKA inclination sensors offer high ingress protection, are suitable for harsh environments and can be used in temperature ranges from -40 °C up to 80 °C.

  • Leak Detect Stik Liquid Level Sensor

    7100 - AMETEK Drexelbrook

    The 7100 leak detect stik is a liquid level sensor that takes field proven magnetostrictive sensing technology and packages it in a revolutionary new way for greater reliability and for easy installation and mounting.The 7100 leak detect stik has PPM (Pulse Position Modulated) outputs for product and interface level and for temperature measurement, which are all superimposed on the two wire power line.All sensor electronics used in this liquid level sensor are SMT components integrated into the 5/8” diameter sensing tube. This breakthrough in package design eliminates the bulky electronics enclosure at the top of the sensor and offers you greater options for insertion.

  • MAX PH/ORP/ISE/Temp Logging Bench Meter

    MW160 - Milwaukee Instruments

    The Milwaukee MW160 4-in-1 MAX pH/OPR/ISE/Temp. Logging Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is cccurate to ±0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key.  In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW160 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.

  • MAX PH/ORP/Temp Bench Meter

    MW150 - Milwaukee Instruments

    The Milwaukee MW150 MAX 3-in-1 pH/OPR/Temp. Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is accurate to ± 0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key.  In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW150 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.

  • Nano-ITX SBC With Intel® Celeron® Processor J1900/N2807, LVDS/VGA/HDMI, Dual LANs And Audio

    NANO842 - Axiomtek Co., Ltd.

    The NANO842 Nano-ITX motherboard is designed to support the Intel® Celeron® processors quad-core J1900 and dual-core N2807 (code name: Bay Trail). A DDR3L SO-DIMM socket located on the bottom of the board can support up to 8GB of DDR3L memory. It can handle operating temperatures from -20°C to 70°C, and runs on +12V DC input. This 120 x 120 mm industrial embedded board comes with multiple display outputs: HDMI, LVDS and VGA with visual experiences enhanced for dual-view supported. The Axiomtek NANO842 is an ideal solution aimed at embedded, industrial, and IoT applications.

  • Process Panel Meters

    Shimpo Instruments

    Rugged and reliable, the 1/8 din panel meter line is designed for both the OEM and retrofit markets with an array of flexibility enabling usage in a broad range of applications. Our Panel Mount Tachometers are ideally designed for speed, rate or time monitoring applications with potential connection to PLC’s and networks with available outputs. The dedicated Process Meter line-up allows usage in virtually any application with their voltage, current or temperature input selections along with a myriad of optional output signal and communication combinations. The similarly designed Process Counter line completes the offering, geared for frequency or encoder input applications.

  • RH Temp Data Loggers

    Monarch Instrument

    The Track-It™ RH/Temp Data Logger is a battery powered stand alone compact data logger that records up to 32,000 samples each of Relative Humidity and Temperature data. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.

  • RS232 / RS485 / RS422 To Fiber Optic Converters

    CommFront Communications

    Our rugged, industrial-grade, point-to-point RS232 / RS485 / RS422 serial to fiber optic converters work in pairs to extend serial signals (RS232, RS485, RS422, and TTL) over long distance. These point-to-point RS232 / RS485 / RS422 serial to fiber optic converters have been designed for harsh industrial environments and withstand a wide temperature of -40°F to 185°F (-40°C to 85°C),  and they come with the options of multi-mode (extend distance up to 3 miles / 5km) and single-mode (extend distance up to 25 miles / 40 km), and ST, SC, and FC connectors.

  • Thermal Imaging Camera Attachment for iOS and Android

    FLIR ONE - Teledyne FLIR

    Explore the world around you in ways you never thought possible. Simply attach FLIR ONE to your smartphone or tablet and experience a new vision of the world. FLIR ONE offers non-contact spot temperature measurement, patented MSX Technology, and automatic shuttering. Plus, the FLIR ONE App offers thermal panoramas and timelapse. FLIR ONE features both FLIR's revolutionary Lepton thermal camera and a VGA visible light camera. Using MSX Technology, FLIR ONE blends images from both cameras to create thermal images with enhanced detail and resolution.

  • Bench Power Supply, Linear, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A

    72-2690 - Tenma

    The 72-2690 from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).

  • Bench Power Supply, Linear, Adjustable, 1 Output, 0 V, 60 V, 0 A, 2 A

    72-2695 - Tenma

    The 72-2695 from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +30mV (voltage), ≤0.5% +5mA (current).

  • Bench Power Supply, Linear, Programmable, 1 Output, 0 V, 30 V, 0 A, 5 A

    72-2710 - Tenma

    The 72-2710 from Tenma is a single channel programmable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).

  • Bench Power Supply, Linear, Programmable, 1 Output, 0 V, 60 V, 0 A, 2 A

    72-2715 - Tenma

    The 72-2715 from Tenma is a single channel programmable bench power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +30mV (voltage), ≤0.5% +5mA