  • Infrared Moisture Analyzer

    LD-LIMA-A10 - Labodam

    Infrared Moisture AnalyzerLD-LIMA-A10is an online, fast, continuous measurement and non-contact measurement device with measurement distance range of 20 to 40 cm. It provides automated control and 4 to 20 mA current signal. This IR Moisture Analyzer emits different wavelengths of infrared light (4, 6, 8, 10 beam) to calculate the moisture content of the measured object. Designed with long-life high-speed brushless motor, imported high response infrared sensors, information processing chip FPGA + DSP + ARM9 combination, to attain real time data, improved stability and precision.

  • Saybolt Color Analyzer

    optek

    optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.

  • Trace VOC Analyzer

    PTR-TOF 6000 X2 - Ionicon Analytik Ges.m.b.H.

    The new PTR-TOF 6000 X2 is our premium PTR-TOF trace VOC analyzer. We conceived a unique system comprising of a novel high-resolution TOF and IONICON’s PTR technology with the new “X2” features, for the ultimate PTR-TOFMS experience. X2 combines the latest generation of performance enhancing tools incl. the ION-BOOSTER funnel as well as the hexapole ION-GUIDE. The ion funnel focuses the ions into the hexapole ion guide which results in nearly lossless transmission of an extremely focused ion beam into the TOF mass spectrometer. This increases the sensitivity dramatically and also improves the instrument’s mass resolving power. Utmost resolution, sensitivity and lowest real-time detection limit are now available in a robust, transportable platform that is smaller and lighter than previous products.

  • Gas Filter Correlation CO2 Analyzer

    ​Model N360 - Teledyne Advanced Pollution Instrumentation

    The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model N360M - Teledyne Advanced Pollution Instrumentation

    The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Process EDXRF Spectrometer

    NEX LS - Applied Rigaku Technologies, Inc

    Featuring advanced third generation EDXRF technology, the Rigaku NEX LS represents the next evolution of scanning multi-element process coatings analyzers for web or coil applications. To deliver superior analytical performance and reliability, the EDXRF measuring head assembly was derived from the established Rigaku NEX Series high-resolution benchtop instrumentation. With this proven technology, the Rigaku NEX LS delivers rapid, non-destructive, multi-element analyses — for coat weight, coating thickness and/or composition — for elements from aluminum (Al) through uranium (U). The measuring head is mounted on a rigid beam and is equipped with a linear traversing mechanism positioned over a roller so that the head-to-surface distance is constant. Common applications include silicone release coaters, converters, denesting Si for vacuum-formed plastics, RoHS compliance, conversion coatings, metalized plastic, top coatings on metal coil and fire retardants on fabric.

  • Amplitude Detectors with Isolators

    ERAVANT

    Full band waveguide detectors are GaAs beam lead Schottky diode-based detectors that are specially designed for millimeterwave network analyzer applications. With a proprietary circuitry design and careful diode selection, these zero-biased detectors exhibit high sensitivity and extremely flat output characteristics. The below standard offering covers the frequency range of 18 to 170 GHz and offers a 1 MHz video bandwidth and 1 MΩ video output impedance. The standard models also have the capacity to handle a maximum RF input power of up to +17 dBm. The RF interface of these detectors is a standard waveguide with an integrated Faraday isolator to improve the port VSWR. The output voltage polarity is negative and the connector type is a female SMA. Other configurations are offered as custom models.

  • *Pulse Characterization Sensors

    mks Ophir

    Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω