Filter Results By:

Products

Applications

Manufacturers

Analog I/O

Analog I/O are Devices that have the capability of sending and receiving analog signals.


Showing results: 301 - 315 of 424 items found.

  • PXI-6280, 16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Hybrid, Multifunction I/O Module

    779120-01 - NI

    16 AI (18-Bit, 625 kS/s), 24 DIO, PXI Multifunction I/O Module—The PXI‑6280 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PCI-6280 , 16 AI (18-Bit, 625 kS/s), 24 DIO PCI Multifunction I/O Device

    779108-01 - NI

    16 AI (18-Bit, 625 kS/s), 24 DIO PCI Multifunction I/O Device - The PCI‑6280 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

    780054-07 - NI

    16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

    780053-01 - NI

    16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

    780054-04 - NI

    16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PCI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.8 MS/s), 24 DIO PCI Multifunction I/O Device

    779109-01 - NI

    The PCI‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

    780054-01 - NI

    16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

    780053-04 - NI

    16 AI (18-Bit, 625 kS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6341, 16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device

    782250-01 - NI

    16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device - The USB‑6341 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB‑6341 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6341, 16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device

    781438-01 - NI

    16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device - The USB‑6341 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB‑6341 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6341, 16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device

    782251-01 - NI

    16 AI (16-Bit, 500 kS/s), 2 AO (900 kS/s), 24 DIO USB Multifunction I/O Device - The USB‑6341 offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB‑6341 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6351, 16 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device

    781440-01 - NI

    16 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6351 offers analog I/O, digital I/O, and four 32‑bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI‑STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB‑6351 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • FlexRIO

    NI

    The FlexRIO product line was designed for engineers and scientists who need the flexibility of custom hardware without the cost of custom design. Featuring large, user-programmable FPGAs and high-speed analog, digital, and RF I/O, FlexRIO provides a fully reconfigurable instrument that you can program graphically with LabVIEW or with VHDL/Verilog.

  • PXI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module

    779629-01 - NI

    The PXI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.

  • PXIe-6259, PXIe, 32 AI (16-Bit, 1.25 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module

    779778-01 - NI

    The PXIe-6259 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.