Showing results: 106 - 120 of 218 items found.
-
Veer Electronics
TRMS Voltage 600V /1200V Phase,1050V / 2100V Line TRMS Current 80A / 160A Direct USB , RS-232 / RS-485 interface & Free Software 20 X 4 LCD Display & Ultra Glow Red LED Display High Speed Measurement in 0.25Sec (Optional) Tamper Proof Calibration & Long term stability User Friendly Operation NABL certified in EQDC & ERDA
-
Rotronic Measurement Solutions
The ROTRONIC HygroPalm handheld instrument of the AirChip3000 generation are the perfect instruments for climatic measurements. They are extremely precise and feature many practical functions, but are easy to use. HygroPalms are adjusted and configured during production and are therefore ready for immediate use. They can be configured for specific applications with userfriendly HW4 software or directly on the keypad. A large range of interchangeable probes enables easy and flexible use, straightforward maintenance and simple calibration.
-
U2049XA -
Keysight Technologies
Wide dynamic range (-70 to +20 dBm) for small signal measurements LAN/ Power-Over-Ethernet (PoE) connectivity for long distance remote monitoring (up to 100 meter)TVAC compliant for operation in vacuum Best-in-class long term drift performance Internal zero and automatic calibration saves time and reduces measurement uncertainty Easy measurement start-up with new intuitive BenchVue software
-
S95090B -
Keysight Technologies
The S95090B spectrum analyzer (SA) measurement software adds high-performance microwave spectrum analysis to PXI VNAs. With fast stepped-FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The S95090B software uses the PXI network analyzer's test and reference receivers to complete simultaneous spectrum measurements. Multi-channel SA measurements leverage the PXI VNA's internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The S95090B spectrum analyzer software application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy. Optional external attenuators should be connected with the VNA’s test ports to avoid receiver compression when measuring large signals.
-
Extech VPC300 -
Extech Instruments Corporation
The VPC300 is a Video Particle Counter with built-in Camera. Measures up to 6 channels of particle sizes plus air temperature and relative humidity. Used for capturing videos and photos that are stored onto internal memory or a micros card. The VPC300 can measure up to 6 channels of particle sizes plus air temperature and relative humidity. Use the included software to generate reports with videos, photos and data points. Complete with NIST-traceable calibration certificate, Universal AC Adapter/Charger with multiple plugs, USB cable, PC software, tripod, filter, 7.4V NiMH battery and a hard, protective case.
-
MeX -
Alicona Imaging GmbH
MeX is a stand alone software package that turns any SEM with digital imaging into a true surface metrology device. Using stereoscopic images the software automatically retrieves 3D information and presents a highly accurate, robust and dense 3D dataset which is then used to perform traceable metrology examination. The results are obtained irrespective of the SEM magnification providing metrology at macro and micro levels. No additional hardware is necessary to run MeX and it can be used with any SEM. Due to the unique AutoCalibration routine the calibration data is automatically refined. Thereby only MeX enables traceable 3D measurements at any magnification in the SEM.
-
Model 308 -
OAI
Dependable and repeatable, The OAI Model 308 UV Intensity/Power Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data logging of intensity mode, time, wave length, serial number and calibration due date.
-
Instrument Systems Optische Messtechnik GmbH
Optical spectrometers analyze the spectral characteristics of light radiation. Adding optical probes and absolute calibration turns this type of measurement system into a spectroradiometer. Since software is used to calculate all radiometric, photometric and colorimetric quantities from spectral data, the quality and precision of the spectrometer is extremely important. This is why Instrument Systems is dedicating most of its research and development work to this field in order to be positioned at the leading edge of technology.
-
FISCHERSCOPE X-RAY/XAN 500 -
Helmut Fischer AG
Mobile measurement of coatings on large parts such as housings, machine components or pipes Stationary measurement on small parts; the compact carrying case transforms the device into a complete desktop unitThree-point sample support ensures safe, and repeatable measuring, and accommodates curved surfacesTime-effective measurement even without calibration due to FISCHER's fundamental parameterEvaluation and presentation of measurement data on a tablet PC (via Bluetooth) using the proven software WinFTM
-
DVTest Inc.
The DVTEST LD Positioner is a two-axis elevation over azimuth positioner, for precise angular positioning with full spherical coverage. The LD Positioner is designed for the precise characterization of lightweight devices. The positioner is constructed from a low-permittivity polymer, for minimal reflections and multipath. For increased accuracy, the motor is outfitted with an absolute encoder, and laser guided calibration. A USB controller is included, with the positioner operated via Python or Matlab software libraries.
-
WPM-19 -
Notice
•19λ CWDM Wavelength Meter– Auto λ detection for CWDM 19-wavelength– Auto power calibration & display•FTTx/PON Wavelength Meter– 1310/1490/1550nm auto λ detection– Auto power calibration & display•Optical Power Measurement– Optical network power measurement– Power measurement for system & module•Insertion Loss Measurement– Optical network & component IL measurement– IL measurement for CWDM 16-wavelength•Smartphone Interface– Communicates with smartphone via bluetooth– Smartphone application software
-
WPM-1NM -
Notice
•Wide range Wavelength Meter– Auto λ detection from 1270nm to 1610nm– Auto power calibration & display•FTTx/PON Wavelength Meter– 1310/1490/1550nm auto λ detection– Auto power calibration & display•Optical Power Measurement– Optical network power measurement– Power measurement for system & module•Insertion Loss Measurement– Optical network & component IL measurement– IL measurement for CWDM 16-wavelength•Smartphone Interface– Communicates with smartphone via bluetooth– Smartphone application software
-
Solidus Technologies, Inc.
olidus Technologies’ can design and build a test system customized for your exact needs, using our own or off the shelf components:Custom MEMS Test Systems. We can integrate and assemble test equipment and handling systems to fit your requirements. Custom MEMS Test Software. We can write custom software for device-specific calibration and testing, interfacing various instruments and handling systems, or create a customized GUI. We can also adapt our standard STI Test Software to work on your hardware system.
-
ELEMENTS -
ELTRA GmbH
The comprehensive Windows-based ELEMENTS software is an essential part of all ELEMENTRAC generation elemental analyzers. A central window (analysis and results) is the starting point from which all functionalities required for the daily routine are easily accessible. From here it is possible to group and export analyzed samples, or register and analyze new ones. The user may call up various subordinate functionalities like application settings, calibration, diagnosis, or status.
-
R140 -
Copper Mountain Technologies
R140 Vector Network Analyzer (cable and antenna analyzer) delivers lab grade performance in a handheld device. This patented (US Patent 9,291,657) analyzer can be connected directly to the antenna or other DUT without the need for a test cable, eliminating measurement uncertainties inherent to cables. Resulting in highly dependable performance and calibration stability. The 1-port VNA comes with all the features engineers have come to expect included standard in our software.