Filter Results By:

Products

Applications

Manufacturers

Microphones

convert sound pressure to an electrical current.

See Also: Phone, Telephone, Geophones, Headphone, Hydrophones, Measurement Microphones, Mic, Electroacoustic, Headset


Showing results: 256 - 270 of 280 items found.

  • Configurable Data-Logging System

    NI CompactDAQ - NI

    This NI CompactDAQ configurable data-logging system includes an NI CompactDAQ controller or chassis, C Series I/O modules, and Chameleon software. It is designed for structural test and monitoring applications with the NI CompactDAQ controller, which includes built-in processing and nonvolatile storage for running Chameleon software and logging data locally. Alternatively, you can choose a USB or Ethernet chassis for a lower cost system that requires an external PC. This system accepts a variety of C Series I/O modules, so you can mix and match microphones, accelerometers, and temperature and bridge-based sensors.

  • PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device

    779307-01 - NI

    The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.

  • Sound Level Meters

    PCE Instruments

    A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.

  • Mobile Cable Fault Location System

    BAUR Syscompact 4000 - BAUR Prüf- und Messtechnik GmbH

    Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle

  • Camera Barrel Test System

    BK8612 - BaKo Co., Ltd

    We designed the BK8612 2 Channel Noise Test System to provide noise and vibration testing for your digital camera barrel DC Motors. Because it is based on the BaKo BK2120B DAQ, it is capable of monitoring a microphone and an accelerometer concurrently to obtain data from the motor. Because you can change the parameters of functions and limits, it is versatile but still quick and easy to set up. In addition, you can look at data in real time and also store it for future analysis. Easy to use and set up, fast and accurate; if you need to maintain the quality of your camera barrel motors, this is the tester you want.

  • Digital Telephone Hybrid

    DMTH4 - Lectrosonics, Inc.

    The DMTH4 integrates telephone lines, video codecs and external audio sources into the digital bus structure of DM Series processors so these sources operate as though they are another microphone or audio input in the sound system. The unit is much more than just a telephone interface. Instead, it is a complete DM Series digital matrix processor, with a 3-in/24-out digital matrix, automatic mixing and comprehensive signal processing on every input and output. In essence, it simply connects to telephone lines, video codecs and external audio sources instead of mic/line inputs and outputs and integrates seamlessly with DM Series matrix processors.

  • Real Time Audion Spectrum Analyzer

    True Audio

    TrueRTA's audio spectrum analyzer software shows you a detailed picture of what you're hearing in real-time, that is, as it happens. You can create your own professional measurement system starting with TrueRTA software on your PC. Then add the measurement microphone, preamp and USB interface of your choice. TrueRTA accurately tests audio systems using a Windows PC with basic sound capability. TrueRTA turns your PC into a powerful audio test system normally seen only in better audio research and design laboratories. TrueRTA runs under Windows Vista, 7, 8 and 10.

  • Simulation & Analysis Solution for Automotive Audio Networks

    A2B Analyzer System - Mentor Graphics Corp.

    The A2B Analyzer System is designed specifically for development teams servicing automotive OEMs, Tier 1s, and audio connectivity equipment suppliers. The deterministic nature of the A2B technology makes it particularly well-suited for automotive audio devices (active speakers, microphones) and newer applications such as ANC. The A2B Analyzer System consists of a compact hardware device, an accompanying software development kit (SDK), and network configuration and simulation tools.. The hardware device includes a USB 2.0 interface for PC connectivity for audio data and command/control functions. The small form factor device also features a variety of popular audio and connectivity peripherals.

  • NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module

    783610-01 - NI

    8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.

  • PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module

    779687-01 - NI

    204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.

  • PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device

    779309-01 - NI

    The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.

  • Class 2 Sound Pressure Level Meter

    Castle Sonus GA216B - Castle Group Ltd.

    This class 2 Sound Level Meter (GA216B) is a feature packed instrument that is fully complient with IEC 61672-1:2002. This meter provides you with the ability to measure sound pressure (Lp) and peak (Cpeak) simultaneously, a requirement for multiple tasks including initial spot-check assessments to the Control of Noise at Work Regulations 2005. The body is designed from tough, crack resistant ABS plastic, ensuring your new Sound Level Meter will survive the conditions for which it was intended. Coming with a high specification measurement microphone which has been calibrated before you receive it, you can be sure your readings are accurate from day one.

  • Noise Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.

  • Comprehensive Simulation of Master, Slave and End Nodes in A 2 B ® Networks

    Infotainment Test Device ITD 1024 - NOFFZ Computer Technik GmbH

    The complexity, cost and weight of audio systems are significantly reduced with the Automotive Audio Bus (A 2 B ® ) from Analog Devices Inc. Regardless of their hierarchical structure or use as master or slave, all A 2 B ® products must be adequately tested before use. This applies, for example, to HiFi amplifiers/loudspeakers, head units, eCall systems, microphones, vibration/noise suppression units, actuators or sensors.Our small and very compact infotainment test system ITD 1024 takes on this task for you: It comprehensively and extremely reliably tests all A 2 B ® signals and communication in all phases of the product development process - during development, for validation and in production.

  • LCR Meter

    TH2826 - Changzhou Tonghui Electronic Co., Ltd.

    TH2826 series is a new generation impedance test instrument and firstly in conformity with LXI standard inland. It fulfills most low-voltage parameter measurement needs for components and materials with its basic accuracy (0.1%), wide frequency range(from 20Hz to 5MHz). The instrument is widely applied in microphone, resonator, inductor, ceramic capacitor, LCD, varactor and transformer .etc to analyze electrical performance and test low-ESR capacitor and high-Q inductor. With the super high test speed, TH2826 series is especially for frequency response curve analyzing of detector and piezoelectric device on auto production line. Its multiple output impedance mode can be used for different standards of inductor or transformer manufacturers.

Get Help