Showing results: 121 - 135 of 280 items found.
-
INSTOCK Wireless Components, Inc
INSTOCK Wireless 350-1000 MHz RF power divider combiners are optimized for UHF, RFID, and TETRA power splitting and combining applications. Wireless microphone systems also typically operate in UHF frequencies, making an INSTOCK device ideal for splitting or combining antennas in UHF wireless microphone systems. Available in 2-way thru 48-way configurations with Type N, SMA, TNC and BNC connector configurations INSTOCK.
-
CAL250 -
Larson Davis, Inc.
The Larson Davis Model CAL250 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
CRY6151B -
CRYSOUND
CRY6151B is a full-featured electroacoustic tester newly launched by CRY Sound. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, anti-noise), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.
-
Model KM-20/ YF-20 -
Kusam Electrical Industries Limited
• One-handed simple, easy to operate.• Inbuilt reference signal.• Inbuilt battery test.• Quickly, accurately measures sound level.• Compressed scales minimise range switching.• An internal reference signal is available for checking the meter’s operation.• Calibration Check• Microphone with Capacitance Microphone.
-
CRY6125 -
CRYSOUND
CRY6125 Electroacoustic tester is a full-featured electroacoustic device tester with resistance to environmental noises. It is designed to measure the performance indicators of microphones, electret microphones (MIC), transmitters, receivers, earphones, headset microphone assemblies, communication helmets, speakers/loudspeakers, buzzers and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, quality factor Q, equivalent volume, and audio power amplifier, etc. Its measurement frequency can be up to 10 Hz - 65 kHz.
-
Cirrus Research plc
The outdoor noise kit has been designed to protect the sound level meter and the microphone capsule from adverse weather and other contaminents that may affect the measurements.
-
CAL150 -
Larson Davis, Inc.
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
CAL200 -
Larson Davis, Inc.
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
CRY6151 -
CRYSOUND
CRY6151 Electroacoustic Analysis System is a full-featured electroacoustic device tester launched by CRY Sound. It has a history of 10 years. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, common), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), communication helmets, loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.
-
Noise Plug -
GTC Industries, Inc.
The NOISE PLUG is a complete precision pink noise generator built in a XLR microphone connector. Inside the NOISE PLUG is an ultra wideband, avalanche junction white noise source.
-
AWA6221A -
Hangzhou Aihua Instruments Co., Ltd.
*Comply with IEC 60942 class 1*Pocket size, portable unit *Frequency 1000 Hz, give independence of weighting*Sound pressure independent of microphone equivalent volume
-
NK021 -
Castle Group Ltd.
This NK021 system includes a class 1 integrating sound level meter, class 1 acoustic calibrator, protective microphone windshield and is supplied in a hard wearing kit case.
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
Metra has been manufacturing amplifiers for piezoelectric transducers for over 50 years. We offer economic charge amplifiers and signal conditioners for IEPE transducers including microphones.
-
Scien Co., Ltd.
Facility fault diagnosis measuring instrument with technology that accurately tracks the heating part and abnormal noise generating part during operation of machinery using thermal imaging camera and microphone
-
Brüel & Kjær Sound & Vibration A/S
Our calibration solutions meet the broad variety of needs for calibration in the field of sound and vibration accurate primary and secondary calibration of measuring equipment and the scope of transducers: accelerometers, microphones and hydrophones.