Showing results: 196 - 210 of 1985 items found.
-
60-552-003 -
Pickering Interfaces Ltd.
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
60-552-007 -
Pickering Interfaces Ltd.
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
60-552-901 -
Pickering Interfaces Ltd.
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
60-552-902 -
Pickering Interfaces Ltd.
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
PXI-7931 -
ADLINK Technology Inc.
ADLINK PXI-7931 is a matrix module with 32 cross-point 2-wire relays (DPDT, 2 Form C). The default configuration of the PXI-7931 itself is a 4-group 2x4 2-wire matrix. With the termination board, TB-6231, users could flexibly choose one of the configurations: one 4x8, two 4x4, one 2x16, two 2x8 and four 2x4. Any contact of the PXI-7931 can connect to other contacts, individually or in combination. The PXI-7931 matrix module simplifies the wiring and makes it easy to change the internal connection path. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7931, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
40-525A-002 -
Pickering Interfaces Ltd.
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also available in a 34x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system.
-
60-550-023 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-550-026 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-550-027 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-550-028 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-550-024 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-550-025 -
Pickering Interfaces Ltd.
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-891-007 -
Pickering Interfaces Ltd.
The 60-891-007 is a compact 50 Ω microwave switching matrix with a maximum bandwidth of 18 GHz. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance rear panel mounted N-type connectors.
-
40-525A-001 -
Pickering Interfaces Ltd.
This is a PXI signal insertion and monitor matrix with switched pass thru connections on both X and Y axis. It is also availablein a 16x4 format and can be used for signal insertion and monitoring purposes on connections between the UUT and test system. Each pass thru connection from LX to X can be open or closed to allow the programmatic disconnection of the signal to check the response of the UUT. The matrix can be used to connect test equipment, such as a DMM or scope, to monitor the pass thru signals via Y connections while the LY connections can be used to insert a fault condition or insert external signals. When external signals are injected the LX connections can be opened and the LY connections closed.
-
40-535-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.