40-536-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.
-
40-537-021-S -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-519B-002 -
Pickering Interfaces Ltd.
The 40-519B-002 is a 32x4 2-pole medium density matrix module and is designed for switching medium voltage/power signals in test applications where reed relays do not have sufficient rating. They are also suitable for telecoms applications where send and return signals need to be switched simultaneously.
-
40-533A-022 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-533A-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
60-310-302 -
Pickering Interfaces Ltd.
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
60-310-202 -
Pickering Interfaces Ltd.
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
40-548-001 -
Pickering Interfaces Ltd.
Model 40-548-001 is a high density single 1-pole 20x4 power matrix module. It is also available in single 10x4, dual 10x4 or single 10x8 relay formats: Typical applications include power routing in Functional ATE systems, specifically automotive electronics, for example testing of Engine Management Units.
-
60-311-003 -
Pickering Interfaces Ltd.
The 60-311 is a 2-pole Matrix Module available with one, two or three separate 75x4 matrices housed in the same case. It is capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle.
-
60-311-001 -
Pickering Interfaces Ltd.
The 60-311 is a 2-pole Matrix Module available with one, two or three separate 75x4 matrices housed in the same case. It is capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle.
-
60-311-002 -
Pickering Interfaces Ltd.
The 60-311 is a 2-pole Matrix Module available with one, two or three separate 75x4 matrices housed in the same case. It is capable of cold switching 750VDC continuous with a carry current of 2A plus higher pulse conditions e.g. typically 1000VDC for 1s with low duty cycle or 6A for 200us with <1% Duty Cycle.
-
40-332-002 -
Pickering Interfaces Ltd.
Designed for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. This range is available in 12x2 or 6x4(shown here)matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
40-534A-021 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
40-534A-021-S -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
40-534A-022 -
Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.