Showing results: 1 - 15 of 105 items found.
-
ATG 2 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
ATG 6000 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
aixACCT Systems GmbH
Our polarity and burn-in test systems are available for components such as multilayer, disc type or hollow ceramics.
-
CD1 -
North Atlantic Industries
The CD1 provides 6 Chip Detect and Fuzz Burn interface(s). A Chip Detector (CD) is a magnetic-electrical device that provides a reliable method of detecting impending failure of bearings and gears.
-
MCPS -
Test Electronics
The most important features of this burn in power supply is its ability to hold a constant output for each channel even in the event that a unit under test on one channel may short and fail. Since each channel has it''s own transformer, no glitches or voltage spikes can get into any of the other channels. This image shows the results as the second channel from the left is shorted with a small wire and the circuit breaker pops out. Used for burn-in testing and other timed testing where power isolation is required. Very basic simple circuit, see schematic below. Cleans and frees up benchtops, burn in racks and work space clutter. Available in benchtop or rackmount.
-
MS-W2034P2 -
MEET International Ltd.
This is a Palm Size external wireless connectivity Digital Multimeter integrated with 4000 Count, True RMS, auto and manual measurement.
-
MS-W2046P2 -
MEET International Ltd.
This is a external wireless connectivity Digital Multimeter integrated with 6000 Count, True RMS auto and manual measurement.
-
MS-W2044P2 -
MEET International Ltd.
This is a external wireless connectivity Digital Multimeter integrated with 4000 Count, True RMS auto and manual measurement.
-
MS-W2036P2T -
MEET International Ltd.
This is a Palm size, external wireless connectivity Digital Multimeter integrated with 6000 Count, True RMS auto and manual measurement.
-
M233F -
SDL Atlas
To determine the comparative burn rates and burn resistance of textiles, particularly those for automotive interior use. Comprised of draft free stainless steel cabinet with observation window, sample holder and door mounted burner. Manual control of timing and gas supply.
-
TF311 -
TESTEX Testing Equipment Systems Ltd.
Horizontal Flammability Tester, to determine the comparative burn rates and burn resistance of textiles, particularly those for automotive interior use. Horizontal flammability tester is safe and easy to operate, Comprises draft free stainless steel cabinet with observation window, sample holder and door mounted burner.
-
Part Number: -
TESTEX Testing Equipment Systems Ltd.
Horizontal Flammability Tester, to determine the comparative burn rates and burn resistance of textiles, particularly those for automotive interior use. Horizontal flammability tester is safe and easy to operate, Comprises draft free stainless steel cabinet with observation window, sample holder and door mounted burner. Horizontal Flammability Tester complies with ISO 3795, ASTM D5132,FMVSS 302, etc.
-
MMPD -
McGan Technology
McGan Technology’s MMPD-8K electrosurgical insulation defect detector is a battery operated unit that tests the integrity, such as pinholes, cracks or defects, of the insulation of electrosurgical instrument in order to prevent inadvertent tissue burns which may occur during electrosurgical instrument procedures. The integrity of the insulation of electrosurgical instruments can occur over time, through normal surgical use, through the accidental contact with a sharp instrument or the rubbing of the insulation to the point of abrading it. The insulation failure provides an alternate pathway for the current to leave the instrument’s electrode usually beyond the sight of the surgeon which will result in the unintended tissue burn. Using an electrosurgical test equipment maintenance program can greatly reduce the number of these inadvertent burns during electrosurgical procedures.
-
MM513 -
McGan Technology
McGan Technology’s MM513 electrosurgical insulation defect detector is a compact, hand held, battery operated unit that tests the integrity, such as pinholes, cracks or defects, of the insulation of electrosurgical instrument in order to prevent inadvertent tissue burns which may occur during electrosurgical instrument procedures. The integrity of the insulation of electrosurgical instruments can occur over time, through normal surgical use, through the accidental contact with a sharp instrument or the rubbing of the insulation to the point of abrading it. The insulation failure provides an alternate pathway for the current to leave the instrument’s electrode usually beyond the sight of the surgeon which will result in the unintended tissue burn. Using an electrosurgical test equipment maintenance program can greatly reduce the number of these inadvertent burns during electrosurgical procedures.
-
TESTEX Testing Equipment Systems Ltd.
Blanket Flammability Tester, to determine the ignition resistance property of blanket fabrics(blanket fabric burn test). Blanket Flammability Tester complies with ASTM D4151, etc.