Showing results: 526 - 540 of 1031 items found.
-
LD3 -
North Atlantic Industries
A linear variable differential transformer (LVDT) is a type of electrical transformer/transducer used for measuring linear displacement (position). A counterpart to this device used for measuring rotary displacement is called a rotary variable differential transformer (RVDT). The RVDT is like an LVDT in that it measures a positional displacement, however, the displacement, which is still a linear proportional function, is based on rotary instead of linear positional movement.
-
LD2 -
North Atlantic Industries
A linear variable differential transformer (LVDT) is a type of electrical transformer/transducer used for measuring linear displacement (position). A counterpart to this device used for measuring rotary displacement is called a rotary variable differential transformer (RVDT). The RVDT is like an LVDT in that it measures a positional displacement, however, the displacement, which is still a linear proportional function, is based on rotary instead of linear positional movement.
-
PeakTech Prüf- und Messtechnik GmbH
A type of power supply that works by switching current into a high-frequency transformer or inductor at frequencies much higher than the input or line frequency
-
CP TC12 -
OMICRON electronics
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
7000 -
Cambridge Instruments & Engineering Co.
Ideal for speedy and accurate testing of Breakdown / withstand test of transformer and circuit breaker oil, in accordancewith IS 6792 : 1992 for oil testing.
-
XMC-1553-x -
ALPHI Technology Corporation
1 or 2 UTMC SUMMIT• UT69151DX-GPC• BC / RT / BM• On-chip Transceivers• On-board Transformers• Long stub / Short stub
-
PCIe-1553-x -
ALPHI Technology Corporation
1 or 2 UTMC SUMMIT• UT69151DX-GPC• BC / RT / BM• On-chip Transceivers• On-board Transformers• Long stub / Short stub
-
Qualitrol
The Neoptix product line includes fiber optic temperature sensors for transformer windings temperature monitoring and for laboratory, industrial, and medical applications.
-
6300A -
Eltel Industries
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
Kharkovenergopribor Ltd.
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
DCSS502BC -
Sanshine Electronis Co., Ltd.
Resistance meter is designed to measure copper resistance of transformers, wires, cables, other conductors and other coil products etc. It is widely used of low resistance measurement of switches, heater wires, transformers, relays, motors, electric films and PC circuit boards, wires, cables, etc. With reliable Good/ NG judgement, it is a premier resistance meter for the use in production line or QC department.
-
TRM 50+ -
Scope T&M Pvt, Ltd.
SCOPE introduces 50 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 50 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
TRM 25 -
Scope T&M Pvt, Ltd.
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
BA Series -
b2 High Voltage
The ultra light BA series Breakdown Analyzers by b2hv are superlative in their specification and ideally suited for both laboratory and on-site transformer oil testing.
-
STS 3000 LIGHT -
Altanova Group
STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker