Filter Results By:

Products

Applications

Manufacturers

Similar Topics: Transformers

Transformer

transfers of electricity from one circuit to another by electro-magnetic induction.

See Also: Transformer Testers, Power Distribution, Coil


Showing results: 571 - 585 of 1031 items found.

  • Oil Dissipation Factor Tester

    MG-III - Chongqing Kailian Yongrun Industrial Co.,Ltd.

    It is designed to determine the dissipation factor (Tan Delta), capacitance and resistance of transformer oil and other liquids. Relative dielectric constant and volume resistivity are calculated automatically and displayed.

  • Insulation Tester, Digital Megohmmeter, 500V, 1kV, 1.5kV, 2.5kV, 5Gohm to 100Gohm, 202 mm

    72-9405 - Tenma

    Tests the insulation integrity of wires, arrestors, transformers, motors, and other electrical devices. Digital display for easy reading. Battery operated device works with the press of a button.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Digital to Synchro Converters

    DSP - Computer Conversions Corporation

    The DSP Series are high efficiency, AC Reference powered, Transformer Isolated, continuously updating “whole” Digital to Synchro Converters, designed for high performance Military and Industrial applications.

  • Gyro Simulator for Aircraft or Bench Use

    TA-256A - Tech-Aid Products

    This is a transformer isolated gyro simulator that can substitute for the KI256 attitude indicator and thus eliminate the requirement to remove that gyro to a remote stand and route a vacuum or pressure source out to the aircraft.

  • Switch-Mode Isolated Power Supply

    Renesas Electronics Corp.

    Renesas offers a wide selection of PWM controllers designed for switch-mode DC/DC and AC/DC power supplies requiring an isolation transformer, such as off-line AC/DC and -48V telecom-input DC/DC converters.

  • Electricity Meters Tester

    TE30 Lite - Calmet Smart Calibration Devices

    Electricity meters tester class 0.02%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.

  • Power Supply Designer

    Intusoft

    Combines the ICAP/4Windows Power Deluxe tool suite (above); Magnetics Designer for the design and synthesis of all types of transformers and inductors; and Library Manager parts management system. 

  • ST Fully-auto BDV Dielectric Oil Tester Set

    Chongqing Assen Power Equipment Co., Ltd

    ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.

  • Test Probe

    MP21 - Rod-L Electronics

    Ideal for hipotting transformers, PCBs and other small assemblies. Four-finger-trigger must extend probe tip before the test can begin. The tester will shut down if the trigger is released

  • AccuLoss®

    ALMS Systems - Measurements International Ltd.

    The measurement of electric power and energy at high voltages and currents at low power factors is becoming increasingly important economically as a way to reduce costs in an ever-growing industrial economy. Today the transformer purchaser subjects the transformer manufacturer to an economic penalty for losses that occur in load and no-load conditions. To keep these penalties as low as possible, it is important that the manufacturer accurately measure these losses. Failure to do so can result in the manufacturer losing important contract awards to their competitors who may be utilizing a more accurate system.

  • Current Caliper

    KH23101 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.

  • MCB Magnetic (Instantaneous) Trip Test Bench

    SCR ELEKTRONIKS

    The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!

  • Cable Electric Resistance Tester

    MR 270 C-A - Schuetz Messtechnik GmbH

    The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

Get Help