Showing results: 616 - 630 of 1031 items found.
-
Schweitzer Engineering Laboratories, Inc.
Underground faulted circuit indicators identify the faulted cable section without a time-consuming re-fuse and sectionalize process. Applications include subsurface or pad-mounted transformers, switchgear, sectionalizing cabinets, junction boxes, and splices.
-
JYL-200B/100B -
Kingrun Instrument Co., Ltd.
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
PeakTech Prüf- und Messtechnik GmbH
Is a component that provides power to an electrical device. The simplest design of power supply is the linear power supply, which uses a transformer and a rectifier to convert voltage from a wall outlet into the type of power the device needs.
-
Eltel Industries
Resistivity meterRSM-500 is used for measuring the volume resistivity of transformer oil and other electrical insulating liquids. • Auto ranged from 109 to 1015 ohm cm • Test voltages: internally generated +500V DC
-
TD 5000 -
Altanova Group
The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range.
-
HA5 -
Summit Technology, Inc.
Our HA5 Current Probe covers the measurement range from 20 milliamps to 5 amps, making it the best choice for measuring very small loads and the outputs of CT (Current Transformer) step-down circuits.
-
HT2055 -
HT Italia Srl
HT2055 consists in a power unit and a voltmetric unit, necessary for carrying out step and contact voltage measurements in industrial electric installations (TN systems, transformer cabinets) with a rated test current up to 50A.
-
GDZRS-20A -
HV Hipot Electric Co.,Ltd.
GDZRS series Winding DC resistance tester is optimal designed for measuring three phase winding DC resistance of big capacity transformer. It can test three phase winding DC resistances at the same time
-
Power Diagnostix Systems GmbH
On-site transformer testing is the main application of Power Diagnostix' mobile high voltage AC test system. However, it can be used as well for other on-site testing, such as of GIS, rotating machines, or high voltage cables.
-
PowerBeam 300 -
CTRL Systems, Inc.
The PowerBeam 300 accurately pinpoints source of ultrasound to within 1 degree from center and improves the sensitivity of the UL101. The "PB300" was originally designed for the indication and location of corona discharge and arcing on medium/high voltage transformers.
-
Laycock Systems
Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.
-
DIR CT -
Scope T&M Pvt, Ltd.
SCOPE proudly introduces Dir CT, a CT Polarity Tester specially designed to verify correctness of polarity of current transformers cores in live EHV switchyards. Polarity test is one of the most common yet crucial tests required to be done on current transformers by commissioning as well as maintenance engineers. Even though it is commonly conducted check, there was no all in one simple tool available for this measurement. DIR CT fills this void to perfection, it is expected to significantly reduce the time taken for polarity checks on numerous CT in sub-station, especially during commissioning of new sub-stations
-
JYQ -
Kingrun Instrument Co., Ltd.
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
Series PRM -
Kepco, Inc.
These units are modular ferroresonant MIL-STD-461-compliant voltage stabilizers which obtain their source-isolated, overload-protected output from Kepco's proprietary transformer, Flux-O-Tran. This design lends itself to custom volt-ampere combinations, consult factory.
-
Series FT -
GE Digital Energy
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.