  • IP67 waterproof outdoor Split core ct

    LZCK-55 200/5A 0.5S - Beijing GFUVE Electronics Co.,Ltd.

    Outdoor waterproof Split Core CTs. Waterproof outdoor split core current transformer 55mm. Outdoor Split-core CTs are designed to meet the growing demand for outdoor installation. The working temperature and humidity is high. Parameters will be measured and compared without power supply cut-off on account of the split core, so it's popular in the energy management system and power factor correction. It can be used along with many kinds of instruments and devices.

  • LCR Meter

    SS10X Series - Sanshine Electronis Co., Ltd.

    LCR Meters are basic passive component testing equipment, can be used in quality management department or production process for quality inspection. Like as: transformer, inductor, resistor, capacitor, relay, motor, generator, electric valve, contactor, cable, wire, etc. This series LCR meter, offering different kind of testing fixtures, can improve testing precision and reduce the difference value of error code, being an economical and useful basic testing instrument.

  • isoPower

    Analog Devices Inc.

    Analog Devices isoPower® technology utilizes proprietary iCoupler® chip scale transformers to integrate isolated dc-to-dc converts with data isolation into a single package. This enables designers to implement isolation in designs without the cost, size, power, performance, and reliability constraints found with optocouplers. With more than one billion channels shipped into the field, these magnetically isolated products are a safe, reliable and easy-to-use alternative to optocouplers.

  • Turns Ratio Meter 3 Phase

    TR-MARK III 250V - Raytech AG

    The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.

  • AC Hysteresis Graph Test System

    DX-2012M - Dexing Magnet Tech. Co., Ltd

    Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.

  • Hybrid Wound Component EST Scanner

    19035 - Chroma Systems Solutions, Inc.

    The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.

  • L.V.D.T Products

    Columbia Research Laboratories

    Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.

  • Insulation Tester, Analogue / Digital Megohmmeter, 50V, 100V, 250V, 500V, 1kV, 0.01ohm to 20Gohm

    72-3105 - Tenma

    Insulation Resistance Tester Full function DMM includes AC and DC voltage measurement, plus a wide range of resistance scales designed specifically for insulation resistance measurement. It is ideal for safety and preventative maintenance work on powered tools, motors, transformers and similar devices. Large backlit 6000 count display provides at-a-glance readings via both 3-3/4 digit readout and 45 segment analog bargraph.

  • Turns Ratio Meter

    Model TRM200 - Gopal Electronics

    Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.

  • Digital Insulation Testers

    The Motwane Manufacturing Company

    Motwane is India’s first company to design and develop an intelligent digital insulation tester that conducts insulation resistance tests on high voltage electrical equipment. Products like transformers, generators, motor cables, bushings, LAs, and switchgear, are prone to gradual degradation over time due to the adverse effects of temperature, humidity, and dust. The gathered test data allows clients to verify the current quality of insulation, and take appropriate action.

  • PC104 MIL1553A & MIL1553B Board

    MS 1701 - Meltronics Systemtech

    *Bus Interface - Standard ISA Bus (PC104 Interface)*One Dual Redundant MIL-STD-1553 Channels, Enhanced Mini-ACE BC/RT/MT Architecture*A periodic message insertion, Real-time bus playback with RT edit mode*Highly Autonomous Bus Controller Architecture, Message Scheduling*Bulk Data Transfers, Data Block Double Buffering*Asynchronous Messages, Retries and Bus Switching*Transformer or Direct Coupled 1553B Channels

  • Isolated Gate Drivers

    Analog Devices Inc.

    Analog Devices’ isolated gate driver portfolio offers designers performance and reliability advantages over designs utilizing optocouplers or pulse transformers. Utilizing ADI’s proven iCoupler® technology, the isolated gate driver family offers the advantage of a maximum propagation delay of 50 ns, less than 5 ns channel-to-channel matching, a 50-year lifetime for 400 V rms working voltage and galvanic isolation in a single package.

  • Primary Test Equipment

    LET-1000-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

  • Primary Test Equipment

    LET-400-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

  • LV Iron Core Shunt Reactors

    Hilkar

    Iron core Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system. Shunt Reactors are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. Shunt Reactors can be directly connected to the power line or to a tertiary winding of a three-winding power or distribution transformer.