  • IPX5 IPX6 Water Spray Test Device

    CX-IPX56B - Shenzhen Chuangxin Instruments Co., Ltd.

    Drop rain rain chamber Uses: This equipment is main to test the physical and other related properties of the products in the environment of simulated rain, such as electronic and electrical products, lamps, electrical cabinets, electrical components, automobiles, motorcycles and their parts and components. After the test, through the test result to determine

  • Software

    BatteryPro - Chroma Systems Solutions, Inc.

    The software is item driven with built-in tests – meaning no programming is required at all. Users are able to read data from the BMS controller and also includes thermal chamber control. Battery Pro Software supports Chroma’s regenerative battery cyclers and provides a safe and stable testing environment.

  • XRF

    L Series - Bowman

    The L Series is the most versatile instrument that Bowman offers. It combines all of the features of the P Series with a larger sample chamber and greater X-Y stage travel. For samples larger than ~12 inches (300 mm) in any direction, the L Series is a must-have. The large sample stage and travel allows for both large parts, or large sample fixtures holding multiple parts, to be measured. The chamber is fully enclosed and boasts a capacity to hold samples up to 22″ (550mm) x 24″ (600mm) x 13″ (330mm) (LxWxH). The X-Y stage travel distance is 10″x10″ (254mm x 254mm). The standard configuration includes a 4-position multiple collimator assembly, and a variable focus camera allowing for measurement in recessed areas. As with other models, the collimator sizes and focal distances are customizable for different customer applications. The programmable X-Y stage is included, but can be removed to allow for the maximum sample height capacity (10″ (254mm) z-height with stage, 13″ (300mm) without). The solid-state PIN detector is included along with our long-life micro-focus x-ray tube. The high performance SDD detector is an optional upgrade.

  • Hybridization Oven

    REXMED ROV-201 - REXMED Industries Co., Ltd.

    MOD. ROV-201, AC 110/230V, Plug type: , Hybridization oven, HS CODE: 841780, UNCCS CODE: 484352, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~85˚C, Stability at 37˚C: ±0.1˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 1.2KW, Shaking timer: 999/min, 999/hr, shaking timer can be set in second, minute or hour function and at the end of operation audio and visual warning, Motor: Noiseless powerful brushless induction motor 15W, Rotation: 5~60rpm adjustable, Rotator: for 8pcs(optional), Orbital: 20~250rpm adjustable, Platform: L30 X W20cm, Chamber: L35 X W25 X H42.5cm, Capacity: 37.2L, chamber with glass viewing window, Optional: Rotator for 8pcs X 1set

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model N360M - Teledyne Advanced Pollution Instrumentation

    The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Gas Filter Correlation CO2 Analyzer

    ​Model N360 - Teledyne Advanced Pollution Instrumentation

    The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the eff​ects of ambient CO2, if necessary.

  • Near Field Probes

    Com-Power Corporation

    A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.

  • QuadStat

    EA164 - eDAQ Pty Ltd.

    The QuadStat is a software-controlled four-channel potentiostat. Each channel can be used as a single three-electrode potentiostat. Alternatively two (bipotentiostat), three, or four working electrodes can be used in a single reaction chamber with a common reference and auxiliary electrode. Potential at each working electrode can be independently adjusted between 2.5 V, or by using an external waveform generator to between 10 V. The QuadStat can measure currents from pico- to milliamperes, making it ideal for amperometric biosensor research including use as a multichannel monitor for in vivo nitric oxide or dissolved oxgen sensors.

  • X-ray fluorescence measuring instrument

    FISCHERSCOPE X-RAY/XULM - Helmut Fischer AG

    Flexible instrument for measuring coating thickness with multiple usesBoth thin and thick coatings (e.g. 50 nm Au or 100 m Sn) can be measured equally well through selectable high voltage filter combinationsThe micro-focus tube enables small measurement spot sizes at short measurement distances of just 100 mHigh count rates of a few kcps through proportional counter tubeMeasuring direction from bottom to top, this allows for quick and easy sample positioningLarge measurement chamber with a cutout (C-slot)

  • Accumulation Leak Detector

    LDS3000 AQ - INFICON Holding AG

    LDS3000 AQ is the first leak detector to use forming gas or helium in a simple accumulation chamber. Leak detector uses cost efficient forming gas or helium for accumulation leak testing. The LDS3000 AQ is very sensitive and can detect leaks down to the 10-5 mbar∙l/s range. It will detect fluid leaks as reliably as helium vacuum leak testing, but with cost nearly at the cost of air testing. The real differentiator: The leak detector uses the cost efficient forming gas or helium for accumulation leak testing.

  • Digital Dust Monitor

    3443 - KANOMAX USA, Inc.

    The Kanomax Digital Dust Monitor – Model 3443 measures aerosol concentrations corresponding to PM10. The intake isolates the aerosol sample so that the optics chamber is kept sterile for improved reliability and low maintenance. The unit measures 0.1 to 10µm particle size aerosol contaminants such as fumes, dust, smoke and mists. It is battery-operated, data-logging, light-scattering laser photometer that gives you real time aerosol mass readings. It is also suitable for clean office settings well as harsh industrial workplaces, construction and environmental sites, and outdoor applications.

  • Extra Large Photoreactor With Heating Capabilities.

    Luzchem Research Inc.

    The new Extra Large Photoreactor(LPD) is designed to meet stringent specifications while maximizing convenience of operation. Features include:*Sequential photochemical and thermal cycles in a single chamber optimized for dual photothermal decontamination.*Programmable exposure time.*Includes rotor/carousel to ensure samples are evenly exposed to UV irradiation.*Front window with UV protection (420 nm cut off) allows operator to inspect. No UV exposure and no need to open compartment.*Magnetic interlock shuts down system for operator safety if front window is removed.

  • X-RAY Fluorescence Measuring Instruments

    FISCHERSCOPE X-RAY/XUL - Helmut Fischer AG

    For coating thickness measurements in the electroplating industryFixed aperture and fixed primary filterX-ray tube with a slightly larger primary spot, well suited for applications with measurement spot sizes starting at about 1 mmLow-energy beam components are excited with lower effectiveness, however for standard applications measuring the thickness of typical electroplated coatings such as Cr, Ni, Cu, this poses little to no problemMeasuring direction from bottom to top, this allows for quick and easy sample positioningLarge measurement chamber with a cutout (C-slot) Standard X-ray tube, proportional counter tube

  • Plasma Etcher / Asher

    PA-3000-A ETCHER - TEK-VAC INDUSTRIES Inc.

    Process chamber with plasma view window and full access hinged door. RF hot process shelves with opposing ground electrodes. Throttle valve. Capacitance manometer. Internal pumping system with option for Fomblin filled chemical series mechanical pump. Flow control electronics and cabinet. Up to four mass flow control assemblies can be incorporated into our system. RF matching network and 600 watt maximum power supply. Fully enclosed cabinet. Custom internal fixturing to accommodate specific substrate shapes and sizes. Plasma gas selection for optimal performance.