Filter Results By:

Products

Applications

Manufacturers

Amplitude

Amplitude Intensity Modulation

See Also: Interference


Showing results: 151 - 165 of 354 items found.

  • PXIe-5654, 250 kHz to 20 GHz, PXI RF Analog Signal Generator

    783127-02 - NI

    PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.

  • PXIe-5654, 250 kHz to 20 GHz, PXI RF Analog Signal Generator

    783126-02 - NI

    PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.

  • MINX Sensors

    MINX0003 - ExpressSense

    ExpressSense introduces the MINX sensor suite, a plug-and-play sensor solution, featuring five built in sensors, delivering automatically-generated process control charts as a web page, viewable from any network connected device. User configured triggers enable email or text alerts to inform user when specific conditions are detected, or MINX can automatically control another device or machine. MINX can be installed and setup in as little as 10 minutes. MINX includes all hardware and software, plus no subscriptions are needed and all the data is kept locally on the unit for maximum security and value!MINX Sensors: Ambient Temperature & Humidity; Optical distance or count optical events; Measure shock/vibration/acceleration amplitude or count events; Remote Temperature via thermocouple; Measure user supplied external analog sensor (0-5V or 0-20mA), either amplitude or record events .

  • Video Pulse Generator

    MS 1811 - Meltronics Systemtech

    *4 Channels of Variable Pulse / Amplitude Output*Pulse Generation Delay between any Two Channels can be Programmable between 2ns to 1ms*Pulse Width can be programmed from 20ns to 268ms (Range: 60ns � 2Sec, Resolution: 2ns, Accuracy: �5ns)*Programmable Pulse PRI (Range: 0ns � 2Sec, Resolution: 10ns, Accuracy: �5ns)*Delay Amongst Channels (Range: 0 � 1.34S, Resolution: 2ns, Accuracy: �5ns)*Rise Time and Fall time is less than 5ns (Programmable Slew Rate 2ns to 10ns � Optional)*Pulse Amplitude can be Programmed between 50mV to 6V (Range: 0 � 6V, Resolution: 10mV)*Channels can be terminated with different loads (50W,75W and 90W)*Standard ISA Bus Interface*Clock (Frequency: 100MHz, Source: Internal/External)*Driver interface for Windows2000/XP/VISTA and LINUX OS

  • Dual Channel Synthesizer

    SYNTH1400X2 - Furaxa, Inc.

    Convenient Ethernet ApplianceControllable from anywhere by computer or mobile device100KHz to 1400MHz frequency tuning in 190 picoHertz stepsTwo synthesizers are independently programmableBoth synthesizers track due to common reference16-bit phase tuning resolution12-bit amplitude scalingProgrammable modulusAutomatic linear and nonlinear frequency sweeping capabilitySwitchable frequency/phase-offset profilesUltra-low phase noiseOptional pulse comb generator output

  • HUM DETECTOR (DEMODULATOR)

    HD-500 - Matrix Test Equipment Incorporated

    The MATRIX Model HD-500 is a detector-amplifier designed to demodulate the low frequency amplitude modulations on any RF carrier over the range of 5 to 1500 MHz. These modulations are usually the undesirable result of the 50 or 60 Hz power source and are not necessarily sinusoidal. The unit is calibrated to the SCTE definition of hum modulation, which is the ratio of the peak-to-peak hum modulation to the peak of the carrier.

  • PAM4 Optical Reference Transmitters

    ModBox-PAM4 series - iXblue sas

    The ModBox-PAM4 serie is a 4-level Pulse Amplitude Modulation (PAM4) Optical Reference Transmitters that generate excellent quality PAM4 optical data streams up to 28 Gbaud, 56 GBaud. The ModBox-PAM4 integrates also: ER4 / LR4: CWDM or LAN-WDM 4 lasers sources, SR4: 850nm laser source, PON: 1310 nm and 1490 nm laser sources.

  • Phase Meter

    6000A - Clarke-Hess Communications Research

    The Model 6000A Phase Meter replaces the very popular Model 6000. Using the latest digital techniques and optimally designed analog front end, the Model 6000A out-performs any other phase meter on the market today. It also does this at a remarkably low cost. The unit automatically selects the proper range for both amplitude and phase and is waveshape independent.

  • Synthesizer Modules

    LA19-15-03 - LA Techniques Ltd

    We offer multi-decade synthesizer modules capable of operation beyond 8 GHz. A good example is theLA19-15-03 module capable of tuning from 300 kHz to 8 GHz with a 10 ppm settling time of 45 us forany size tuning step. It provides 10 Hz resolution, +15 dBm output with 30 dB of amplitude control.

  • Three-Phase Relay Test Equipment

    AK-6 - Amperis sl

    *5 automatic or manual test modules: DC test, AC test, distance test, harmonics and frequency protection*Phase, frequency and amplitude are continuously and independently adjustable.*All-in-one design: built-in Windows CE & rotary encoder & keyboard & 6.4" TFT LCD (RJ45/USB for updates and downloads)*High power: 3x450VA at 0...35A average voltage test

  • Analog Control Variable Gain Amplifiers (VGAs)

    Analog Devices Inc.

    Analog Devices voltage controlled variable gain amplifiers provide continuous gain control over a wide dynamic range for a variety of audio and optical frequency bands. Our VGAs improve the dynamic range of a circuit by allowing users to adjust a signal’s amplitude in real time, which is invaluable for ultrasound, speech analysis, radar, wireless communications, and instrumentation-related applications.

  • 8 GHz Agile Synthesizer

    PicoSource™ AS108 - Pico Technology Ltd.

    The PicoSource™ AS108 Agile Synthesizer generates signals to meet the needs of both benchtop and integrated module applications. Its broad 300 kHz to 8 GHz frequency range, fast settling and programmable phase, frequency and amplitude match it to a wide range of applications, with the added advantages of low cost, small footprint and 12 to 15 V power requirement.

  • Fixed Attenuators

    DC to 220GHz - Precision Milimeter Wave

    RF Attenuators are components that reduce the amplitude level of an incoming frequency signal. They are used to protect systems from receiving a signal with a power level that is too high to process. There are various types of fixed attenuators that can fit your engineering needs. Precision MMW will help you with the highest quality fixed attenuator products needs.View more Fixed Attenuators

  • 0.1Hz-5MHz Functional Generator

    MFG-3005 - MCH Instruments Co.,Ltd.

    *Frequency range: 0.1Hz~5MHz*Output waveforms: Sine ,triangle, square, positive and negative pulse, positive and negative ramp*Output impedance: 50Ω±10%*Output Amplitude: Not less than 20Vp-p(open circuit)*DC voltage: 0~±10V continuously adjustable*Symmetry range: 90:10—10:90*Rising edge of square: Less than 100ns

  • Axle Damping Test

    MSD 3000 | VP 215033 - Maschinenbau Haldenwang GmbH & Co. KG.

    The axle damping test stand MSD 3000 is characterized by a quick and precise physical check of the axle damping. The frequency-controlled plate excitation by means of electric motors determines the maximum oscillation amplitude and then evaluates the axle damping according to the principle of Lehr's damping. The fully automatic test sequence including the determination of the axle and vehicle weight enables a time-saving and reliable assessment of the axle damping.