  • LXI WTB Terminator, 100 ohm

    60-983-001 - Pickering Interfaces Ltd.

    The 60-983 is an LXI compatible Wired Trigger Bus Terminator (WTB) designed to be attached to the end of a WTB cable. The LXI WTB uses a transmission line cable to connect LXI devices together that support the WTB capability of the LXI standard. Like all transmissions it needs to be correctly terminated to avoid reflections that could change the signal amplitude along the cable and generate timing jitter or trigger errors. The 60-983 is a simple terminator that can be placed at each end of the WTB chain to correctly terminate the transmission line with minimal reflections.

  • Ultrasonic Level Transmitters and Switches

    ABB Ltd.

    Ultrasonic Level Measurement features variable GAP technology for stable readings in the most challenging environments.The KSONIK is the only ultrasonic level transmitter that uses dynamic GAP technology in order to locate the correct echo. The KSONIK utilizes the minimum amount of GAP (Gain, Amplitude, and Power) at every possible distance within the measurement range. This simply means that we reduce the power to give you the most accurate reading with a beam angle of only 3 degrees, and then enough power to push through the most dusty environments.

  • Sensors

    IRD Balancing

    To measure machinery or structural vibration, a transducer is needed to convert the mechanical motion into an equivalent electrical signal. Each sensor has distinct advantages in certain situations and limitations in other, so it is important to select the most suited transducer or sensor for your job. Equally, important is selecting the appropriate parameter of vibration amplitude for measurement. IRD® has a wide range of transducers and accelerometers available to help you obtain accurate, reliable data, whether your concern is vibration monitoring, analysis, or dynamic balancing.

  • Astronics PXIe-2461, 235 MHz FrequencyTime Interval Counter

    784197-01 - NI

    PXIe, 42 V, 2-Channel PXI Counter/Timer Module—The Astronics PXIe‑2461 is a high-performance counter/timer module that provides easy-to-use automatic measurement functions, including phase, pulse, peak, rise/fall time, time interval and ratio measurement, all with high resolution. It features nine digits per second resolution, programmable measurement timeout, and nine different arming modes. You can set the Astronics PXIe-2461 to measure timing and amplitude characteristics in one of two voltage ranges: ±5.1 V or ±42 V.

  • Voltage and Current Amplifier

    CMS 356 - OMICRON electronics

    The CMS 356 is a voltage and current amplifier for analog low-level signals provided by a CMC test set or by any other signal source, such as a digital real-time power system network simulator. When used in combination with a CMC test set, the amplifier extends the capabilities of the test set to provide additional output channels and higher amplitudes.

  • AC Hysteresis Graph Test System

    DX-2012SA - Dexing Magnet Tech. Co., Ltd

    Under continuous frequency of 1 kHz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability µa, loss angle d, loss iron Pc, remanence Br and coercivity Hc.

  • HV Test bench

    Techimp HQ S.r.L

    It is a deeply customizable test bench which is suitable to generate frequency and amplitude controlled voltage. This test bench could be used for life test or quality test on samples or devices. It can be configured both for sinusoidal test (STANDARD version) and both for square wave or pulse test (TechSQUARE). It includes safety systems for avoiding overload and incorrect use.

  • MPU- Passive Sensors

    Orbit Controls AG

    sensors of the MPU series are passive elements intended for measuring rotational speeds or speeds of moving parts. The measuring principle is based on voltage induction in the coil through a changing magnetic field, which is caused, for example, by a rotating ferromagnetic gear. The coil is wound on a magnetic core and led out via a cable or a plug. The sensors are manufactured with metric or inch threads or with a flange connection and deliver a sinusoidal output signal, the amplitude of which is proportional to the peripheral speed. They can be connected to Orbit Controls evaluation devices. An OC35-IMP transmitter is available for converting to square-wave signals.

  • Signal Generator

    Tsunami - Arachnid Labs

    The Tsunami is a powerful and flexible signal generator built on the Arduino platform. It's the best way to get started experimenting with analog signals, and a great tool for a huge variety of tasks, too. With its highly accurate crystal, you can use the Tsunami to generate signals - sine, triangle, and square waves - all the way from DC up to around 2 megahertz. A versatile analog frontend allows you to adjust amplitude from 0 to 6 volts peak to peak, and DC offset by up to 2 volts either side of ground.

  • Time Code Distributor/Reshaper

    SR-112 - Brainstorm Electronics Inc.

    Like it’s big brother the SR-112 Distripalyzer, the SR-28 can drive time code over long cables, making it ideal for synchronization during live shows and remote recording. The SR-28 time code distributor, with two inputs and eight outputs, reshapes time code while distributing it, eliminating amplitude distortions and level fluctuations. The level of each output is individually adjustable via front panel pots. The input is selected via a front panel switch. Also included are 2 power inputs and an automatic switch over in case of failure.

  • Wideband Power Analyzer

    2335A - Clarke-Hess Communications Research

    The Model 2335A Wideband Power Analyzer is a precision, high accuracy, high frequency auto-ranging instrument which measures and displays true rms Voltage, true rms Current, and true mean Power over a frequency range from dc to more than 1MHz. Full scale Current and Voltage inputs are typically measured within 0.1% of the amplitude reading to at least 500kHz. The corresponding Power is typically measured to within 0.1% of the input Volt-Amperes to 250kHz and to within 0.2% of the input Volt-Amperes to 500kHz for loads having any Power Factor.

  • Changeover

    LT 4448 - Leader Electronics Corp.

    LThe LT 4448 is a changeover unit that automatically switches the signal from the primary signal to the backup signal when problems are detected in the primary signal.Two systems of input signals (primary and backup) are connected to the LT 4448, and the LT 4448 detects errors in the amplitude of the primary input signal.A single LT 4448 provides 11 pairs of BNC and LTC channels. These channels can receive SDI, NTSC/PAL black burst, HD tri-level sync, AES/EBU digital audio, word-clock, and LTC signals.It can be used in combination with the LT 4610 (Sync Generator).

  • Strainer-Recorder

    ViTec Co. Ltd

    To ensure reliable operation of the measuring complex in the harsh conditions of ice tests, it is based on the industrial measuring platform NI CompactRIO, which provides mechanical strength and operation at negative temperatures.The system provides for operation both under the guidance of an operator with displaying the voltages removed from the ship's hull in the form of graphs on a computer screen connected to the strain gauge station via an Ethernet line, and in stand-alone mode, when the recording of a given duration is initiated by the station on pre-configured events: amplitude exceeding by one of channels, an external discrete signal or periodically at specified intervals.

  • CPCI or PXI DPFS Board

    MS 1830 - Meltronics Systemtech

    - Configurable Frequency Ranges from 100Hz to 1MHz- Resolution insteps of 0.03Hz- Duty Cycle 50%- Amplitude of the Digital Frequency out : Low – 0.4V max, High – 4.8V min- Rise/Fall Time (for a 15pF Load) is typically 5 ns- Amplitude of the Analog waveform out : Low – 0.4V max, High – 4.8V min- Sinusoidal or Square Wave Output (Configurable)- Differential / Single Ended Output (Configurable)- Frequency on each of the 8 Channels are individually Programmable- Hot Swap Facility for live insertion and removal of the board- Facia plate with Micro Switch Assembly, provided for proper insertion / easy removal of the Board- BNC Connector Interface for Signal Output at the front panel- Each Output Channel is driven by a Cable Driver to drive 8m of Coaxial Cable- Driver interface for Windows XP/VISTA/7 and LINUX OS

  • New Line of Frequency Synthesizers (Insight FS) from 36 to 1250 GHz

    Insight Product Company

    In the millimeter wave range, each synthesizer covers a full waveguide band (Q, U, V, E, W, F, D, G, Y, J). Insight FS provides several options for frequency and amplitude modulation (analog FM/AM modulation, frequency manipulation, pulses modulation).  Insight FS are compact in size and controlled by IEEE, analog input, or manually.