Filter Results By:

Products

Applications

Manufacturers

Amplitude

Amplitude Intensity Modulation

See Also: Interference


Showing results: 346 - 355 of 355 items found.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Portable Interface Unit

    1553-USB-PIU - Western Avionics Ltd.

    The 1553-USB-PIU is a Portable Interface Unit providing full MIL-STD-1553 test, simulation and bus analysis capability in a compact self-contained unit, to connect via a USB interface to suitable host systems. The unit provides support for all 1553A, 1553B, McAir and STANAG 3838 variants in a self contained battery operated unit, and is supplied with a matching power supply and battery charger unit for desk-top use. The 1553-USB-PIU supports concurrent Bus Controller (BC) and up to 31 Remote Terminals (RT) with Bus Monitor (BM). An additional stand-alone Chronological Bus Monitor (CBM) facility is also provided, with comprehensive multi-level triggering capability. Full error injection capability is provided in BC and RT modes, with full error detection in BC, RT, BM and CBM modes. The unit provides a variable amplitude dual redundant 1553 interface. 2 Mbytes of dual ported RAM are provided. The unit is supplied with "C" Driver library, together with a Windows GUI, providing a user friendly software tool for all 1553 set-ups, data management and storage.

  • Electrodynamic Vibration Generator System

    LVD-100KG - Lisun Electronics Inc.

    • Vibration table size: 500*500mm (Other size can be designed) • Vibration: 0~5mm (Adjustable range P-P). Vibration waveform: sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable) • Maximum test load Capacity: 100kg • Accuracy: Frequency can be displayed to 0.01 Hz. Precision 0.1 Hz. • Sweep Frequency function (1~600Hz): (Upper frequency, Lower frequency, Time range) It can set real standard arbitrarily to sweep frequency back and forth • Programmable Function (1~600Hz): It can set each segment in 15 segments arbitrarily (frequency/amplitude/time/acceleration), and it can be recycled • Frequency doubling function (1~600Hz): 15 segments multiplied-increase: 1)Low to high frequency 2)High to low frequency 3)Low to high and then to low frequency, it can be recycled • Logarithmic function (1~600Hz), 3 modes of logarithm/can be recycled: 1)Lower to upper frequency 2)Upper to lower frequency 3)Lower to upper and then to lower frequency • Measuring instrument: To display amplitude, acceleration speed and the maximum acceleration speed.

  • 10G DPSK Demodulator

    Optoplex Corporation

    Optoplex’s Optical DPSK Demodulator, also known as Delay Line Interferometer (DLI), converts phase modulation to amplitude modulation over the entire C+L band in support of data transmission rates of 2.5,10 or 40 Gb/s. The DPSK demodulator is designed for phase modulated optical communication systemsutilized in commercial, defense and space exploration markets. The device plays a key role in improvingsignal quality and performance to meet the expanding demand for higher data rates and more complextransmission formats within current and next generation systems without major capital expenditure.Optoplex’s DPSK Demodulator is based on a patented free-space optical design, which is compact, athermal and polarization-independent. The measured frequency drift over temperature is only ~0.02 GHz/°C for our standard passive device. Further, this DPSK Demodulator exhibits a total polarization-dependent phase shift of less than 2 degrees over the entire operating temperature range with a high extinction ratio. Optoplex’s DPSK Demodulators can be configured to be fully tunable, colorless tunable or purely passive. Dual-Rate DPSK Demodulator is also available.

  • 2.5G DPSK Demodulator

    Optoplex Corporation

    Optoplex’s Optical DPSK Demodulator, also known as Delay Line Interferometer (DLI), converts phase modulation to amplitude modulation over the entire C+L band in support of data transmission rates of 2.5, 10 or 40 Gb/s. The DPSK demodulator is designed for phase modulated optical communication systems utilized in commercial, defense and space exploration markets. The device plays a key role in improving signal quality and performance to meet the expanding demand for higher data rates and more complex transmission formats within current and next generation systems without major capital expenditure. Optoplex’s DPSK Demodulator is based on a patented free-space optical design, which is compact, athermal and polarization-independent. Themeasured frequency drift over temperature is only ~0.02 GHz/°C for our standard passive device. Further, this DPSK Demodulator exhibits a total polarizationdependent phase shift of less than 2 degrees over the entire operating temperature range with a high extinction ratio. Optoplex’s DPSK Demodulators can be configured to be fully tunable, colorless tunable or purely passive. Dual-Rate DPSK Demodulator is also available.

  • 20 GHz Signal Source

    VCO Series - SignalCore, Inc.

    The SC5510A and SC5511A are VCO-based, synthesized signal sources with very low phase noise and an amplitude control of 0.01 dB throughout its -30 dBm to +15 dBm output power range. By utilizing a unique multiple phase-locked loop architecture, phase spurs are kept below -70 dBc across the entire tuning range, even at 1 Hz step resolution. Download the data sheet to see how the impressive features and specifications of these modules make them stand out when compared to other small modular synthesizers. These 20 GHz signal sources include an additional, independent RF2 channel with a tunable frequency range from 100 MHz to 3 GHz and a tuning resolution of 25 MHz. The extra channel makes the modules suitable for either single-stage RF conversion systems or dual-stage image suppression up/down converter systems. Both modules make great general-purpose laboratory signal sources where demanding low phase noise and signal purity are required. They are both ideal choices as an integrated clock source for fast DAC and ADC applications, especially those that require variable sampling rates. Full implementation instructions, GUI, driver software, and example code are provided with each module.

  • AC Fuel Flow Signal Generator

    TA-100 - Tech-Aid Products

    The TA-100 signal generator was designed to facilitate testing of aircraft fuel flow indicators that require two input signals designated as “Drum” and “Impeller”. This generator provides both signals so as to provide a direct interface to the fuel flow indicator under test. The generator also provides switched power out to the unit under test as well as a 5v source for testing the bezel lighting. The original design was built around the requirements for the AMETEK series indicators (pn: 10171 series). This generator simulates a reference and a time delayed signal of appropriate amplitude for an indication of up to 1200pph for the indicator under test. The “PPH Select” switch provides fixed signal delays representing 0, 200, 400, 800, 1000 and 1200pph flow rates respectively, this provides the mechanic with an expedient check of the indicators accuracy. The “PPH Adjust” control allows the mechanic to vary the signal delay throughout the full range and serves as a good method for checking of pointer smoothness from stop to stop. The unit’s front panel also provides test jacks to monitor the “FDR Output” as well as the drum and impeller signals. The TA-100 requires only 28Vdc to operate. This generator provides a very economical approach to any repair facility or flight department as it becomes an alternative to purchasing two bench top signal generators. The TA-100 generator at the very least can provide a simple functional test and eliminate the high cost of exchanging an indicator as a function of troubleshooting the aircraft system.

  • Fatigue Testing And Certification

    Hill Engineering, LLC

    Fatigue engineering is subject to uncertainty, and data from well executed tests are used to validate conclusions made by analysis and to provide a basis for structural certification. Our staff have extensive experience in testing materials and components under slowly varying, static loads, and under rapidly varying cyclic loads. Tests under static loads are used to assess material properties or to assess the load-deformation behavior of structural components. Tests under cyclic loads provide time to crack initiation, time to failure, or measurements of crack growth over time. We have extensive experience in measuring fatigue crack growth behavior in metallic materials. Past programs have measured crack growth with microscopy and photogrammetry at the surface, cracked area with direct current potential drop, and through-thickness crack profiles with quantitative fractography. By assessing crack growth with a variety of experimental methods, we enable robust analysis validation for cases of complex cracking. Our capabilities in fatigue engineering allow for careful design of a fatigue test program. Whether the tests use constant amplitude loading or an irregular loading spectrum, we specialize in engineering the test that meet your needs. Much of our experience is in non-standard test programs, which require engineering to optimize the test setup. Few others match our capability and experience in fatigue test engineering.

  • Fuel Display Unit Tester

    MS 1125 - Meltronics Systemtech

    Fuel Display Unit Test Bench is a compact table-top test bench with front panel controls, indications, built-in signal simulator and necessary power supply for testing the serviceability of Fuel Display Unit of Helicopter. FTB operates on 230 V AC and supplies 28 V DC power to FDU. FTB is housed in a metallic cabinet FTB interfaces with both 61 Pin connector and 6-pin socket mounted on the rear panel of FDU by means of the cable connected to the unit.  FTB is fabricated utilizing off-the-shelf standard industrial/commercial components like rotary switches, toggle switches, press switches, test sockets, fuse holders, potentiometer etc. The Frequency generation circuit is integrated into FTB for the simulation of Fuel probe and flow rate signals. The frequency of the signal can be selected by means of a rotary switch Low amplitude sine wave signal is simulated for testing flow rates. Variable voltage DC power supply with a voltage range of 24 to 29 Volts is provided within FTB to power-up FDU. 5 V DC is provided for the operation of signal generating circuit (PIC Frequency Controller Board). An off-the-shelf Hand held battery operated Digital Multimeter (DMM) procured from the prominent manufacturer (FLUKE) is supplied with FTB for setting up and measurement of various parameters like Resistance, Voltage, Frequency etc.

  • AC Power Source

    6500 series - Chroma ATE Inc.

    The global AC power testing requirements demand more sophisticated AC Power Source that is capable of simulating a wide variety of AC line conditions, harmonic waveforms, accurate power measurement and analysis. The Chroma 6500 series Programmable AC Power Source delivers the right solution to simulate all kinds of normal/abnormal input conditions and measure the critical characteristics of the product under test. It can be used for R&D design characterization, production testing, and QA verification of commercial, industrial, and aerospace electronic products. The Chroma 6500 series delivers maximum rated power for any output voltage up to 300 Vac, and at any frequency between 15Hz to 2000Hz. It is suitable for commercial applications (47-63Hz); for avionics,marine, military applications at 400Hz or higher frequency; or for electrical motor, air-conditioner test applications at 20Hz. All models generate very clean sine or square waveforms output with typical distortion less than 0.5%. The Chroma 6500 series has built-in Direct Digital Synthesis (DDS) Waveform Generator to provide user programmable high precision waveform. For testing products under AC line distortion conditions, clipped sinewave can be generated with 0% to 43% distortion and amplitude from 0% to 100%. It also can simulate all kinds of power line disturbances such as cycle dropout, transient spike, brown out, phase angle, voltage and frequency ramp up (ramp down), etc.. Up to 30 harmonic waveforms are factory installed, and testing for compliance to AC line harmonic immunity standards can be easily achieved in the field.

Get Help