Showing results: 76 - 84 of 84 items found.
-
56KS1 -
North Atlantic Industries
NAI’s 56KS1 is a 75 Watt AC/DC Power Supply that accepts multiple AC inputs plus a +270 VDC input. This COTS unit provides full-power, single output, at a baseplate temperature of +85° C.
-
PS5410C-16 -
North Atlantic Industries
The PS5410C-16 is a 5VA AC Reference Power Supply, available with many transformer isolated output voltages at different frequencies. Input power is either 12 VDC or 15 VDC. The standard 15 pin "D" connector simplifies interconnection to other equipment.
-
CAPO-12 -
Raytech AG
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Aero Nav Laboratories, Inc.
The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.
-
Supreme Instrument Laboratories
General Specification for Portable Ammeters, Voltmeters, Milliammeters, millivoltmeters, Micro Ammeters, Single phase Wattmeters, power Factor Meters, Dynamometer type Voltmeters, Ammeters etc. Housed in superior grade of ABS body, unique design, very strong in construction, unbreakable and very high insulation.
-
GTD-81 -
Kingrun Instrument Co., Ltd.
GTD-81 Insulation Oil Dissipation Factor and Resistivity Measuring System DTL, is designed and manufactured based on international standards. It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components.
-
Excelitas Technologies Corp.
Higher-voltage and Higher-power Supplies require more complex design solutions. The heat to be dissipated and installation infrastructure, plus choice of insulation system in a HVPS are driven by the output voltage and output power which ultimately dictates packaging. Typical insulation systems are based on air, dielectric oil, epoxy, RTV Silicone and even Sulfur Hexafluoride (SF6). The method of cooling is a factor as well, the choices often coming down to air, water or oil, depending on the platform design requirements. These applications require Excelitas' detailed understanding to help choose the best design solution.
-
G5.SAS -
Regatron AG
The G5.SAS series are unidirectional sources. It was developed specifically for testing inverters and simulating solar arrays and is suitable for use in laboratories and on test benches. The modular and finely graded G5.SAS series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The power supplies feature especially low capacitance values in the output filter stage and switchable earth leakage resistors for adaptation to the insulation measurement of the DUT.
-
G5.DT -
Regatron AG
The G5.DT series is bidirectional regenerative. It was developed specifically for testing DC components of the electrical drive train or DC components of other parts of the vehicle electrical system. It is suitable for use in laboratories and on test benches. The modular and finely graded G5.DT series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The power supplies are equipped with a powerful CAN multi-protocol interface (1 kHz, 16 bit) and optionally offer test bench relevant safety functions such as PL e according to EN ISO 13849, insulation monitoring as well as automatic discharge on the load side in case of shutdown.