Showing results: 1 - 15 of 43 items found.
-
MG-III -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
It is designed to determine the dissipation factor (Tan Delta), capacitance and resistance of transformer oil and other liquids. Relative dielectric constant and volume resistivity are calculated automatically and displayed.
-
National Technical Systems
Dielectric Constant is used to determine the ability of an insulator to store electrical energy. The dielectric constant is the ratio of the capacitance induced by two metallic plates with an insulator between them to the capacitance of the same plates with air or a vacuum between them. Dissipation factor is defined as the reciprocal of the ratio between the insulating materials capacitive reactance to its resistance at a specified frequency. It measures the inefficiency of an insulating material. If a material were to be used for strictly insulating purposes, it would be better to have a lower dielectric constant.
-
-
CP TC12 -
OMICRON electronics
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
PMT10000 -
Power Measurement Technologies Inc.
High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.
-
Naprotek, LLC.
Beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which allow for use in military and aerospace designs. Their robust performance and small form factor provide repeatable performance.
-
DER EE Electrical Instrument
*Rs, Rp, Cs, Cp, Ls, Lp, phase angle, Dissipation factor, Quality factor *Auto select series or parallel test mode *Auto select 100Hz/1kHz/10kHz test frequency, 0.5V rms approx. *Calibration
-
LCR-900 -
PINTEK Electronics
*Dual LCD Display. *Capacitance, Resistance, Impedance, Inductance, Quality Factor, *Dissipation Factor Phase Angle. *Auto Detect Function. *Open Circuit/Short Circuit Compassion. *Operation Frequency 100Hz to 100KHz. *Basic Accuracy: 0.3% *Measurement Voltage Fixed at 0.6Vrms.
-
PHG 80 TD -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
PHG 70 TD -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
CAPO-12 -
Raytech AG
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Vettiner
Ultra High Voltage standard Capacitors used for very high accuracy measurement of capacitance and dielectric dissipation factor (Tan Delta) as well as voltage measurement in capacitive dividers.
-
Vettiner
High accuracy Schering bridge for the measurement of capacitance and dielectric dissipation factor (tan d) for the characterization of dielectric insulators, calibration of standards and manufacturing test of all industrial equipment.
-
BA6011 -
B&K Precision Corporation
The BA6010 Series battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians.
-
TDX 5000 -
Altanova Group
TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines.